• Title/Summary/Keyword: microwave vacuum

Search Result 210, Processing Time 0.033 seconds

Effect of Microwave Vacuum Heating on Inactivation of Enzymes (마이크로파 진공가열방법이 효소의 불활성화에 미치는 영향)

  • Moon, Eun-Kyung;Han, Ki-Young;Kim, Suk-Shin;Kim, Sang-Young;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.284-291
    • /
    • 1997
  • Microwave vacuum heating method (2450 MHz) was used for a low intensity of heat treatments. High vacuum under the microwave heating could bring low temperature condition. Inactivation of ${\alpha}-amylase,\;{\beta}-amylase$, glucoamylase and peroxidase by microwave vacuum heating were investigated at 60-$80^{\circ}C$. It was compared with conventional heating. The heating condition of microwave vacuum heating was confirmed by the destruction of ascorbic acid. When thermal inactivations of the enzymes by microwave vacuum heating were determined, it was less effective than that of conventional method at the initial stage of heating. It was due to a lag time of microwave heating. However, the heating time for complete inactivation of the enzymes by microwave vacuum heating could be reduced comparing with that of conventional heating. Optimum conditions for inactivation of the enzymes could be obtained by microwave vacuum heating.

  • PDF

Microwave Vacuum Drying of Germinated Brown Rice as a Potential Raw Material for Enzyme Food (잠재적 효소식품 원료로서 발아현미의 마이크로파 진공건조)

  • Kim, Suk-Shin;Kim, Sang-Yong;Lee, Won-Jong
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.1107-1113
    • /
    • 1998
  • This work was to study the potential use of germinated and microwave-vacuum-dried brown rite as a raw material for enzyme food. Brown rice was soaked in water at $15^{\circ}C$ for 2 days and then germinated at $25^{\circ}C$ for 4 days. The germin ated brown rice was then dried by different drying methods: microwave vacuum drying 1(drying only), microwave vacuum drying 2 $(drying{\rightarrow}crushing{\rightarrow}drying)$, hot air drying, vacuum drying and freeze drying. Each drier except freeze drier was set to maintain the sample temperature to be $60^{\circ}C$. During microwave vacuum drying 1 and 2 the sample reached $60^{\circ}C$ much faster (5 min) and was dried much faster (2 to 3 hrs for microwave vacuum drying 1 and 2 than the other drying methods. The initial drying rate of microwave vacuum drying was ten times faster than that of hot air drying. The microwave vacuum drying produced a dry sample of the highly retained enzymic activity, followed by freeze drying, vacuum drying and hot air drying.

  • PDF

Comparative Study on Microwave Probes for Plasma Density Measurement by FDTD Simulations

  • Kim, D.W.;You, S.J.;Na, B.K.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.218.1-218.1
    • /
    • 2014
  • In order to measure the absolute plasma density, various probes are proposed and investigated and microwave probes are widely used for its advantages (Insensitivity to thin non-conducting material deposited by processing plasmas, High reliability, Simple process for determination of plasma density, no complicate assumptions and so forth). There are representative microwave probes such as the cutoff probe, the hairpin probe, the impedance probe, the absorption probe and the plasma transmission probe. These probes utilize the microwave interactions with the plasma-sheath and inserted structure (probe), but frequency range used by each probe and specific mechanisms for determining the plasma density for each probe are different. In the recent studies, behaviors of each microwave probe with respect to the plasma parameters of the plasma density, the pressure (the collision frequency), and the sheath width is abundant and reasonably investigated, whereas relative diagnostic characteristics of the probes by a comparative study is insufficient in spite of importance for comprehensive applications of the probes. However, experimental comparative study suffers from spatially different plasma characteristics in the same discharge chamber, a low-reproducibility of ignited plasma for an uncertainty in external discharge parameters (the power, the pressure, the flow rate and so forth), impossibility of independently control of the density, the pressure, and the sheath width as well as expensive and complicate experimental setup. In this paper, various microwave probes are simulated by finite-different time-domain simulation and the error between the input plasma density in FDTD simulations and the measured that by the unique microwave spectrums of each probe is obtained under possible conditions of plasma density, pressure, and sheath width for general low-temperature plasmas. This result shows that the each probe has an optimum applicable plasma condition and reliability of plasma density measurement using the microwave probes can be improved by the complementary use of each probe.

  • PDF

Changes in Saponin Composition and Microstructure of Ginseng by Microwave Vacuum Drying (수삼의 마이크로파 진공 건조 후 사포닌 조성 및 미세구조의 변화)

  • Kum, Jun-Seok;Park, Kwang-Jang;Lee, Chang-Ho;Kim, Yong-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.427-432
    • /
    • 1999
  • Changes in saponin composition and microstructure of ginseng by microwave vacuum drying were determined. Korean fresh ginsengs were subjected to four different processing : 3 min microwave vacuum drying and 2 min holding-24 hrs drying (MWVD1), 5 min microwave vacuum drying and 2.5 min holding-24 hrs drying (MWVD2), 3 min microwave vacuum drying and 2 min holding-12 hrs drying after hot air drying for 12 hrs drying at $45^{\circ}C$ (HMWVD1), 5 min microwave vacuum drying and 2.5 min holding-12 hrs drying after hot air drying for 12 hrs at $45^{\circ}C$ (HMWVD2). The water content was decreased until 16.82% without shrinkage and water activity was 0.54 after microwave vacuum drying. The lipid content was decreased after microwave vacuum drying (MVD). Glucose was increased after MVD while sucrose decreased. Ginsenoside-Rb1 and ginsenoside-Rc were decreased after MVD. Ginsenoside-Rg1 for MWVD2 and HMWVD2 was higher than that of MWVD1 AND HMWVD1. MWVD1 AND HMWVD1 dried ginsengs showed a more compact structure than the HMWVD2 and HMWVD2 ginsengs.

  • PDF

Preparation and Quality of Dried Yam Chip Snack Coated with Ascorbic Acid Cocrystallized Sucrose

  • Kim, Suk-Shin;Koh, Kyung-Hee;Son, Sook-Mee;Oh, Myung-Suk
    • Food Science and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.661-666
    • /
    • 2005
  • The specific objectives of this study were to dry yam chips using microwave vacuum drying, freeze drying and hot air drying, then to coat the dried yam chips with ascorbic acid cocrystallized sucrose, and finally to compare the quality of yam chip snack foods with respect to drying and coating characteristics. The microwave vacuum dried sample showed the highest drying rates and much less surface damage than the hot air dried one did. The shape and color of the microwave vacuum dried/coated sample were allocated between those of the freeze dried/coated sample and the hot air dried/coated sample. The freeze dried/coated sample scored excessively low in organoleptic hardness and chewiness to be suitable as a snack. The hot air dried/coated sample was too deep in color, wrinkled, excessively high in organoleptic hardness and chewiness, and excessively low in mouthfeeling. Therefore, the microwave vacuum dried/coated sample presented the best overall attributes as a snack, with respect to organoleptic characteristics, shape, color, and drying rates.

High power microwave and millimeter wave generation from vacuum power tubes

  • Park, Jin-Joo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.178-178
    • /
    • 1998
  • Bacuum ppower tubes (gyrotron klystron gyro-klystron etc) are attractive for high ppower applications such as radar/communications pplasma heating accelrator naterial pprocessing etc. Over the ppast two decades considerable efforts on the developpment of gyrotron-ppower coherent microwave and millimeter wave sources were made. Expperimental pperformance on the gyro-devices will be ppresented.

  • PDF

Electron Density and Electron Temperature in Atmospheric Pressure Microplasma

  • Tran, T.H.;Kim, J.H.;Seong, D.J.;Jeong, J.R.;You, S.J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.152-152
    • /
    • 2012
  • In this work we measured electron temperature and electron density of a microplasma by optical emission spectroscopy. The plasma is generated from a small discharge gap of a microwave parallel stripline resonator (MPSR) in Helium at atmospheric pressure. The microwave power supplied for this plasma source from 0.5 to 5 watts at a frequency close to 800 MHz. The electron temperature and electron density were estimated through Collisional-radiative model combined with Corona-equilibrium model. The results show that the electron density and temperature of this plasma in the case small discharge gap width are higher than that in larger gap width. The diagnostic techniques and associated challenges will be presented and discussed.

  • PDF

Application of Conformal Mapping in Analysis the Parallel Stripline Resonator

  • Tran, T.H.;You, S.J.;Kim, J.H.;Seong, D.J.;Jeong, J.R.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.180-180
    • /
    • 2012
  • A microplasma system source based on microwave parallel stripline resonator (MPSR) was developed for the generation of microplasmas in a wide range of pressure from some torr to 760 torr. This source was operated at its resonance frequency that much depends upon not only its discharge gap size but also operated pressure. This paper applied a simple circuit model to analyze the effects of discharge gap size and pressure to resonance frequency and impedance of MPSR in the cases with and without plasma exist inside the discharge gap. In the process of calculating, the conformal mapping method was used to estimate the capacitance of the MPSR. The calculating results by using circuit model agree well with the simulation results that using commercial CST microwave studio software.

  • PDF

Effects of the Sheath on Determination of the Plasma Density of Microwave Probe

  • Kim, Dae-Woong;You, Shin-Jae;Na, Byung-Keun;You, Kwang-Ho;Kim, Jung-Hyung;Chang, Hong-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.181-181
    • /
    • 2012
  • The microwave probe for measuring plasma density is widely used for its advantages: First, it is not affected by the reactive gas. Second, it can measure local plasma parameters such as plasma density, plasma potential and plasma temperature. Third, it is simple and robust. A cut-off probe is the one of the most promising microwave probe. Recently, Kim et al. reveals the physics of the cut-off probe but the effect of the sheath on the determination of the plasma density is not explained. In this presentation, for taking account of sheath effects on determination of plasma density from the cut-off peak, a simplified circuit modeling and an E/M simulation are conducted. The results show that occupation ratio of sheath volume between two tips of the cut-off probe and subsequence pressure condition mainly change position of the cut-off peak with respect to plasma frequency. Magnitude of relative voltage taken on the impedance of sheath and the impedance of bulk plasma can explain this effect. Furthermore, effects of gap size, tip radius, and tip length ware revealed based on above analysis.

  • PDF

Characteristics of Linear Microwave Plasma Using the Fluid Simulation and Langmuir Probe Diagnostics

  • Seo, Gwon-Sang;Han, Mun-Gi;Yun, Yong-Su;Kim, Dong-Hyeon;Lee, Hae-Jun;Lee, Ho-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.158.1-158.1
    • /
    • 2013
  • Microwave는 일반적으로 300 [MHz]~30 [GHz] 사이의 주파수를 가지는 전파로 1 [m] 이하의 파장을 가진다. Microwave를 이용한 플라즈마의 경우 낮은 이온 에너지, 효율적인 전자 가열, 넓은 동작압력 범위, 높은 밀도 등의 장점을 가지고 있어 PECVD(Plasma Enhanced Chemical Vapor Deposition)에 적합한 플라즈마 소스라고 할 수 있다. 또한 Microwave는 파장의 길이가 증착이 이루어지는 진공 챔버의 길이보다 매우 작기 때문에 대면적 적용성이 용이하므로 현재 많은 연구가 이루어지고 있다. 본 연구에서는 Fluid Simulation을 통해 Maxwell's equation, continuity equation, electromagnetic wave equation 등을 이용하여 Microwave의 파워 및 압력에 따른 플라즈마 parameter를 계산하고, 자체 제작한 Linear microwave plasma 장치에서 정전 탐침(Langmuir Probe)을 이용하여 플라즈마 Parameter를 측정하였다. 또한 Simulation 결과와 실험결과를 비교 분석하였다.

  • PDF