• 제목/요약/키워드: monitoring

검색결과 26,157건 처리시간 0.046초

편토압이 심한 도심지 대심도 암반굴착공사에서의 계측사례 (A Case Study on the Field Monitoring of the Deep Rock Excavation Site in Urban Area on Severe Unbalanced Pressure Condition)

  • 김태섭;김웅규;정창원;한철희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1259-1267
    • /
    • 2008
  • One of the most important item for insuring the stability of ground in urban deep excavation site near by major structure such as subway is displacement control of earth retaining wall. The field monitoring system is classified by two types as manual system and automatic system. The application case of latter type of field monitoring is increased because real time measurement is possible in automatic system and that is correspondent with the recent constructional trend. Though the automatic monitoring system is more useful and advanced than manual monitoring system, accuracy of the system is not verified sufficiently. It was examined that the reliance of automatic monitoring system in this paper through the comparison of monitoring result obtained one of deep urban excavation site in which the each type of monitoring system was executed concurrently. Result of the examination is that the two types of monitoring system is generally alike in view of monitoring result, so the engineering reliance of automatic system was confirmed in case site. This study was researched in restricted one case site, so it is expected more precise analysis from security of more data monitored and progressive study.

  • PDF

Optimal Monitoring Intervals and MDA Requirements for Routine Individual Monitoring of Occupational Intakes Based on the ICRP OIR

  • Ha, Wi-Ho;Kwon, Tae-Eun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • 제45권2호
    • /
    • pp.88-94
    • /
    • 2020
  • Background: The International Commission on Radiological Protection (ICRP) has recently published report series on the occupational intakes of radionuclides (OIR) for internal dosimetry of radiation workers. In this study, the optimized monitoring program including the monitoring interval and the minimum detectable activity (MDA) of major radionuclides was suggested to perform the routine individual monitoring of internal exposure based on the ICRP OIR. Materials and Methods: The derived recording levels and the critical monitoring quantities were reviewed from international standards or guidelines by the International Atomic Energy Agency (IAEA), the International Organization for Standardization (ISO), and the European Radiation Dosimetry Group (EURADOS). The OIR data viewer provided by ICRP was used to evaluate the monitoring intervals and the MDA, which are derived from the reference bioassay functions and the dose coefficients. Results and Discussion: The optimal monitoring intervals were determined taking account of two requirement conditions on the potential intake underestimation and the MDA values. The MDA requirement values of the selected radionuclides were calculated based on the committed effective dose from 0.1 mSv to 5 mSv. The optimized routine individual monitoring program was suggested including the optimal monitoring intervals and the MDA requirements. The optimal MDA values were evaluated based on the committed effective dose of 0.1 mSv. However, the MDA can be adjusted considering the practical operation of the routine individual monitoring program in the nuclear facilities. Conclusion: The monitoring intervals and the MDA as crucial factors for the routine monitoring were described to suggest the optimized routine individual monitoring program of the occupational intakes. Further study on the alpha/beta-emitting radionuclides as well as short lived gamma-emitting nuclides will be necessary in the future.

위해성평가 목적의 하천수 모니터링 빈도 연구: 국내상황을 고려한 적정빈도 제안 (Proposed Water Quality Monitoring Frequency for Risk Assessment in Korean Rivers and Streams)

  • 곽진일;윤성지;남선화;안윤주
    • 한국물환경학회지
    • /
    • 제28권3호
    • /
    • pp.473-478
    • /
    • 2012
  • To protect human health and manage increasing hazardous chemicals in stream area, it is necessary to expand water quality hazardous items based on risk assessment with proper monitoring data. Also, it is essential to set up the suitable monitoring frequency to produce reliable exposure data to derive water quality guidelines. However, there has been no harmonized monitoring frequency for risk assessment in both domestic and international monitoring systems. In addition, the monitoring frequency for risk assessment has been selected as 'Research needs' in the International Conference on Deriving Environmental Quality Standards for the Protection of Aquatic Ecosystems (EQSPAE) of 2011. In this study, Cases of UNEP/WHO, EU, European countries, USEPA, ANZECC/ARMCANZ, CCME, Japan, and Korea were analyzed to propose the monitoring frequency for risk assessment. Monitoring frequencies depending on environmental conditions, monitoring object, measurement parameters, and monitoring duration were extensively collected. We observed that a monthly monitoring has been applied at most of organizations including EU, USEPA, and UNEP/WHO. In this study, monitoring frequency of minimum 6 times during 3 years were proposed to conduct the risk assessment based on the current domestic status. However, it is necessary to make agreements among interested parties, and perform additional studies about optimal monitoring frequency to protect the aquatic ecosystem and human health in Korean rivers and streams.

티타늄 합금의 슬롯가공에서 엔드밀 공구마멸 감시 (Tool wear monitoring of end mill in slot machining of titanium alloy)

  • 하건호;구세진;김정석;양순철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 1995
  • A acoustic emission (AE) sensor has been used to monitor tool were during milling process. The relation between tool wear and AE RMS (Root mean Square) signal was investigated experimentally. A avaliable monitoring index for monitoring toolwear was newly extracted form AE RMS. And on-line monitoring program was developed. The proposed monitoring system has verified experimentally by roughing end milling titanium alloy with TIN coated HSS tool.

  • PDF

위험도로사면의 실시간 무인감시시스템 개발 연구 (A Study on Development of Automated Monitoring System for Road Cut Slopes)

  • 김춘식;이광우;윤수호;조삼덕
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.607-614
    • /
    • 2000
  • A cost-effective automated slope monitoring system is developed to monitor hazardous cut slopes along highways. This automated slope monitoring system consists of data-collection and visual monitoring, data-transmitting, database and internet service, and alarm system. Wire-line extensometer, automatic raingauge, and CCD camera are selected as monitoring instruments in this system, after consideration of failure characteristics of roadside cut slopes in the country. This paper describes the important features of this newly developed automated slope monitoring system.

  • PDF

Remote structural health monitoring systems for next generation SCADA

  • Kim, Sehwan;Torbol, Marco;Chou, Pai H.
    • Smart Structures and Systems
    • /
    • 제11권5호
    • /
    • pp.511-531
    • /
    • 2013
  • Recent advances in low-cost remote monitoring systems have made it possible and practical to perform structural health monitoring (SHM) on a large scale. However, it is difficult for a single remote monitoring system to cover a wide range of SHM applications due to the amount of specialization required. For the remote monitoring system to be flexible, sustainable, and robust, this article introduces a new cost-effective, advanced remote monitoring and inspection system named DuraMote that can serve as a next generation supervisory control and data acquisition (SCADA) system for civil infrastructure systems. To evaluate the performance of DuraMote, we conduct experiments at two representative counterpart sites: a bridge and water pipelines. The objectives of this article are to improve upon the existing SCADA by integrating the remote monitoring system (i.e., DuraMote), to describe a prototype SCADA for civil engineering structures, and to validate its effectiveness with long-term field deployment results.

A Study on Monitoring Techniques for Dermal Exposure to Hazardous Chemicals

  • Lee, Su-Gil;Lee, Nae-Woo
    • International Journal of Safety
    • /
    • 제8권1호
    • /
    • pp.18-23
    • /
    • 2009
  • Due to dermal exposure to hazardous chemicals causing potential adverse health symptoms through skin absorption, dermal monitoring has had an important role in assessing such exposure. This paper overviews comparatively a number of studies of dermal monitoring with different methodologies such as surface monitoring, skin wiping, skin washing, adhesive methods and tape stripping, fluorescence and infrared spectroscopy, skin patches, pads and clothing, video exposure monitoring and dermal exposure assessment toolkits and models. However, there is a lack of information on the relationship between exposure levels and adverse health symptoms. Therefore, more specific strategies for dermal exposure monitoring should be developed and standardized with further development of biological and ocular monitoring.

위성항법 지상국 감시제어시스템 품질 감시 기법 분석 (Quality Monitoring Method Analysis for GNSS Ground Station Monitoring and Control Subsystem)

  • 정성균;이상욱
    • 한국항공운항학회지
    • /
    • 제18권1호
    • /
    • pp.11-18
    • /
    • 2010
  • GNSS(Global Navigation Satellite System) Ground Station performs GNSS signal acquisition and processing. This system generates error correction information and distributes them to GNSS users. GNSS Ground Station consists of sensor station which contains receiver and meteorological sensor, monitoring and control subsystem which monitors and controls sensor station, control center which generates error correction information, and uplink station which transmits correction information to navigation satellites. Monitoring and control subsystem acquires and processes navigation data from sensor station. The processed data is transmitted to GNSS control center. Monitoring and control subsystem consists of data acquisition module, data formatting and archiving module, data error correction module, navigation determination module, independent quality monitoring module, and system maintenance and management module. The independent quality monitoring module inspects navigation signal, data, and measurement. This paper introduces independent quality monitoring and performs the analysis using measurement data.

배전반 시스템의 온라인 감시 및 진단 (On-line Monitoring and Diagnostics for Distribution Panel System)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.106-110
    • /
    • 2008
  • Continuous on-line temperature monitoring allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Esophageal pH and Combined Impedance-pH Monitoring in Children

  • Shin, Myung Seok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제17권1호
    • /
    • pp.13-22
    • /
    • 2014
  • Esophageal pH monitoring is considered the gold standard for the diagnosis of gastroesophageal reflux disease because of the normal ranges across the pediatric age range. However, this method can only detect acid reflux. Multichannel intraluminal impedance-pH (MII-pH) monitoring has recently been used for the detection of bolus reflux in infants and children. This method allows for the detection of liquid, gas or mixed reflux in addition to acid, weakly acidic or weakly alkaline reflux. MII-pH monitoring can record the direction of flow and the height of reflux, which are useful parameters to identify an association between symptoms and reflux. However, the technique is limited by its high cost and the lack of normative data of MII-pH in the pediatric population. Despite certain limitations, MII-pH monitoring will become more common and gradually replace pH monitoring in the future, because pH monitoring is part of MII-pH.