• Title/Summary/Keyword: monitoring interval

Search Result 359, Processing Time 0.04 seconds

An Optimal and Dynamic Monitoring Interval for Grid Resource Information Services (그리드 자원정보 서비스를 위한 최적화된 동적 모니터링 인터벌에 관한 연구)

  • Kim Hye-Ju;Huh Eui-Nam;Lee Woong-Jae;Park Hyoung-Woo
    • Journal of Internet Computing and Services
    • /
    • v.4 no.6
    • /
    • pp.13-24
    • /
    • 2003
  • Grid technology requires use of geographically distributed resources from multiple domains. Resource monitoring services or tools consisting sensors or agents will run on many systems to find static resource information (such as architecture vendor, OS name and version, MIPS rate, memory size, CPU capacity, disk size, and NIC information) and dynamic resource information (CPU usage, network usage(bandwidth, latency), memory usage, etc.). Thus monitoring itself may cause system overhead. This paper proposes the optimal monitoring interval to reduce the cost of monitoring services and the dynamic monitoring interval to measure monitoring events accurately. By employing two features, we find out unnecessary system overhead is significantly reduced and accuracy of events is still acquired.

  • PDF

Algorithm for Determining Aircraft Washing Intervals Using Atmospheric Corrosion Monitoring of Airbase Data and an Artificial Neural Network (인공신경망과 대기부식환경 모니터링 데이터를 이용한 항공기 세척주기 결정 알고리즘)

  • Hyeok-Jun Kwon;Dooyoul Lee
    • Corrosion Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.377-386
    • /
    • 2023
  • Aircraft washing is performed periodically for corrosion control. Currently, the aircraft washing interval is qualitatively set according to the geographical conditions of each base. We developed a washing interval determination algorithm based on atmospheric corrosion environment monitoring data at the Republic of Korea Air Force (ROKAF) bases and United States Air Force (USAF) bases to determine the optimal interval. The main factors of the washing interval decision algorithm were identified through hierarchical clustering, sensitivity analysis, and analysis of variance, and criteria were derived. To improve the classification accuracy, we developed a washing interval decision model based on an artificial neural network (ANN). The ANN model was calibrated and validated using the atmospheric corrosion environment monitoring data and washing intervals of the USAF bases. The new algorithm returned a three-level washing interval, depending on the corrosion rate of steel and the results of the ANN model. A new base-specific aircraft washing interval was proposed by inputting the atmospheric corrosion environment monitoring results of the ROKAF bases into the algorithm.

Influence of the Monitoring Interval and Intake Pattern for the Evaluation of Intake (내부피폭 감시주기 및 섭취형태가 방사성핵종 섭취량 평가에 미치는 영향)

  • Jong-Il Lee;Tae-Young Lee;Si-Young Chang;Jai-Ki Lee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.53-59
    • /
    • 2004
  • A variety of factors such as the pattern of intake (acute or chronic), monitoring interval and the characteristics of the radionuclides could have a significant influence on the estimates for the intake and internal dose. The relative differences of the assessed intakes based on the assumption of an acute intake to that of a chronic intake were evaluated by using the predicted bioassay quantity in the whole body or organs for an acute and chronic intake through the inhalation of $^{125}$ I, $^{137}$ C, $^{235}$ U with the AMAD of 1 ${\mu}{\textrm}{m}$ and 5 ${\mu}{\textrm}{m}$ for the monitoring intervals of 7, 14, 30, 60, 90, 120, 180, 360 days, respectively, The relative difference of the assessed intakes based on the intake pattern is affected by the monitoring interval, radionuclide and absorption type, but the particle size has little influence on the difference of the assessed intakes based on the intake pattern. The maximum monitoring interval, which is defined as the monitoring interval that the relative difference of the assessed intakes based on the assumption of an acute intake to that of a chronic intake is less than 10%, is 60 d for $^{125}$ I with Type F, 180 d for $^{137}$ C with Type F, 90 d for $^{235}$ U with Type M, and 360 d for $^{235}$ U with Type S. It was concluded that an intake pattern has little influence on the estimates of the assessed intake in the case where the monitoring interval is shorter than the maximum monitoring interval for each radionuclide.

  • PDF

Design of Energy Efficient MAC Protocol for Delay Sensitive Application over Wireless Sensor Network (무선 센서 네트워크상에서 시간지연에 민감한 데이터 전송을 위한 에너지 효율적인 MAC 프로토콜 설계)

  • Oh, Hyung-Rai;Song, Hwang-Jun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11B
    • /
    • pp.1169-1177
    • /
    • 2009
  • This paper presents an energy efficient MAC protocol for delay-sensitive data transmission over wireless sensor network. In general, energy consumption and delay depend on Channel Monitoring Interval and data sensing period at each sensor node. Based on this fact, we propose a new preamble structure to effectively advertise Channel Monitoring Interval and avoid the overhearing problem. In order to pursue an effective tradeoff between energy consumption and delay, we also develop a Channel Monitoring Interval determining algorithm that searches for a sub-optimal solution with a low computational complexity. Finally, experimental results are provided to compare the proposed MAC protocol with existing sensor MAC protocols.

Multivariate EWMA Control Charts for the Variance-Covariance Matrix with Variable Sampling Intervals (가변추출간격상(假變抽出間格上)에서 분산(分散)-공분산(共分散) 행례(行例)에 대한 다변량(多變量) 기하이동평균(幾何移動平均) 처리원(處理圓))

  • Cho, Gyo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • v.4
    • /
    • pp.31-44
    • /
    • 1993
  • Multivariate exponentially weighted moving average (EWMA) control charts for monitoring the variance-covariance matrix are investigated. A variable sampling interval (VSI) feature is considered in these charts. Multivariate EWMA control charts for monitoring the variance-covariance matrix are compared on the basis of their average time to signal (ATS) performances. The numerical results show that multivariate VSI EWMA control charts are more efficient than corrsponding multivariate fixed sampling interval (FSI) EWMA control charts.

  • PDF

Properties of VSI CUSUM Chart for Monitoring Dispersion Matrix

  • Chang, Duk-Joon;Shin, Jae-Kyoung
    • Journal of the Korean Data and Information Science Society
    • /
    • v.15 no.4
    • /
    • pp.1003-1010
    • /
    • 2004
  • Properties of the variable sampling interval(VSI) CUSUM chart for monitoring dispersion matrix of related quality characteristics are investigated. Performances of the proposed charts are evaluated for matched fixed sampling interval(FSI) and VSI charts in terms of average time to signal(ATS) and average number of samples to signal (ANSS). Average number of swiches(ANSW) of the proposed VSI Shewhart and CUSUM charts are also investigated.

  • PDF

Properties of VSI Charts for Monitoring Dispersion Matrix

  • Chang, Duk-Joon;Kwon, Yong-Man
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2004.04a
    • /
    • pp.151-159
    • /
    • 2004
  • Properties of the variable sampling interval(VSI) control charts for monitoring dispersion matrix of related quality characteristics are investigated. Performances of the proposed charts are evaluated for matched fixed sampling interval(FSI) and VSI charts in terms of average time to signal(ATS) and average number of samples to signal (ANSS). Average number of swiches(ANSW) of the proposed VSI charts are also investigated.

  • PDF

Relationship between the Flow data on the Unit Watersheds and on the Stream Flow Monitoring Network (수질오염총량관리 단위유역 유량자료와 하천유량 측정망 자료의 연계성 분석)

  • Park, Jun Dae;Oh, Seung Young
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.55-65
    • /
    • 2013
  • It is very difficult to apply stream flow data directly to the management of Total Maximum Daily Loads because there are some differences between the unit watershed and the stream flow monitoring network in their characteristics such as monitoring locations and its intervals. Flow duration curve can be developed by linking the daily flow data of stream monitoring network to 8 day interval flow data of the unit watershed. This study investigated the current operating conditions of the stream flow monitoring network and the flow relationships between the unit watershed and the stream flow monitoring network. Criteria such as missing and zero value data, and correlation coefficients were applied to select the stream flow reference sites. The reference sites were selected in 112 areas out of 142 unit watersheds in 4 river basins, where the stream flow observations were carried out in relatively normal operating conditions. These reference sites could be utilized in various ways such as flow variation analysis, flow duration curve development and so on for the management of Total Maximum Daily Loads.

A Development of Maintenance Decision Support System for Gas Turbine Engine (가스터빈 엔진 정비 의사결정 지원시스템 개발)

  • Ki, Ja-Young;Kang, Myoung-Cheol;Lee, Myung-Kuk;Rho, Hong-Suk
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.586-591
    • /
    • 2012
  • The solution of maintenance decision support system for the gas turbine engine, which is currently operating in GUNSAN combined cycle power plant, was developed and is consist of online monitoring module, periodic performance trending module, optimal compressor washing interval analysis module and hot component management module. Also, GUI platform was applied to this solution for the user to monitoring the analyzed result of engine performance condition and then to make a decision of the consequent maintenance action. In online condition monitoring module, the performance degradation of engine is provided by the analysis of difference between the real time measurement data compared to exist engine performance. The optimal compressor washing interval module produced the washing interval of maximum net profit value by researching the maintenance expense and the loss profit value corresponds to the performance degradation with economic assessment algorithm. Thus, this solution support the user to enable the optimal maintenance and operation of gas turbine engine with overall analysis of engine condition and main information.

  • PDF

A Study of ECG Based Cardiac Diseases Diagnoses (심전도 신호를 이용한 심장 질환 진단에 관한 연구)

  • Kim, Hyun-Dong;Yoon, Jae-Bok;Kim, Hyun-Dong;Kim, Tae-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.328-330
    • /
    • 2004
  • In this paper, ECG based cardiac disease diagnosis models are developed. Conventionally, ECG monitoring equipments can only measure and store ECG signals and they always require medical doctor's diagnosis actions which are not desirable for continuous ambulatory monitoring and diagnosis healthcare systems. In this paper, two kinds of neural based self cardiac disease diagnosis engines are developed and tested for four kinds of diseases, sinus bradycardia, sinus tachycardia, left bundle branch block and right bundle branch block. For diagnosis engines, error backpropagation neural network (BP) and probabilistic neural network (PNN) were applied. Five signal features including heart rate, QRS interval, PR interval, QT interval, and T wave types were selected for diagnosis characteristics. To show the validity of proposed diagnosis engine, MIT-BIH database were used to test. Test results showed that BP based diagnosis engine has 71% of diagnosis accuracy which is superior to accuracy of PNN based diagnosis engine. However, PNN based diagnosis engine showed superior diagnosis accuracy for complex-disease diagnoses than BP based diagnosis engine.

  • PDF