• Title/Summary/Keyword: motor handpiece

Search Result 13, Processing Time 0.03 seconds

Development of Battery Type Powered Handpiece Drive System for Surgical Operation (Battery type 외과수술용 핸드피스 구동 드라이브 시스템)

  • Ha, Jung-Jun;Yoon, Yong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.388-394
    • /
    • 2008
  • The purpose of this paper is concerned with a battery type powered handpiece drive system for surgical operation. Battery type powered surgical handpiece is suitable for delicate surgical operating. The conventional air-type handpiece has a mechanical noise, a strong oscillation and a danger of infection. And the conventional contact switching type handpiece has problems that is restricted by surroundings. By reason of this kind, we studied noncontact switching type surgical handpiece to change conventional air type surgical handpiece and contact switching type. Also in this paper we develop the battery type power handpiece drive system for surgical operation using controller IC UC3625 of UNITRODE CO. Finally some experimental and simulation results are provided to demonstrate the validity of the proposed battery type power handpiece drive system.

A study on the usage satisfaction of multi-type handpieces with equipped air-jet function (Air-jet기능을 장착한 멀티형 복합유닛 핸드피스의 사용 만족도 조사)

  • Kim, Im-Sun;Choi, Byung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.37 no.3
    • /
    • pp.169-178
    • /
    • 2015
  • Purpose: This study was to investigate usage satisfaction of multi type handpiece with equipped air-jet function Methods: The subjects of this study through the survey was conducted for fifty-nine dental technicians in Daegu and Gyeongsangbukdo from the May 7 to 19, after the June 23 to July 4 2014. The survey was about the function and quality through user testing environment by cutting zirconia specimens using appliance for zirconia. The collected date was analyzed by the statistical program SPSS Win Ver 19.0 for the satisfaction of handpiece and control system. To test for significance on each item, p<0.05 had been decided a standard. General characteristics and relationship between the handpiece and control system was performed correlation analysis. Results: The results of this study is as follows. 35 dental technicians had 1~2 years career in zirconia part as the highest 59.3%, 95% of subjects expected that the prospects for the zirconia material have bright prospects. The satisfaction of multi type handpiece and control system design and function showed a significant difference. Subjects satisfied with the design and function of the multi type showed negative correlation with those of Standard. The satisfaction of multi type handpiece showed 3.37 points of air jet, 3.05 points of noise level, 2.69 points of water flow rate, and 1.98 points of cruise function. Sample differences in all parameters showed a statistically higher difference. Conclusion: High-speed cutting mechanism of multi-type is recommended working with zirconia materials and the multi-type unit combined handpiece motor, air-turbine and air-gun will be expected the increase of user due to the high satisfaction of air jet.

A Development of the Control System of BLDC Motor for Micro Motor Handpiece (마이크로 모터 핸드피스를 위한 BLDC 전동기 제어시스템 개발)

  • Baik, Won-Sik;Song, Hyun-Jig;Kim, Min-Huei;Kim, Dong-Hee;Lee, Heon-Uk;Hwang, Don-Ha
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.231-234
    • /
    • 2008
  • The permanent magnet BLDC motors are increasingly being used in high performance applications due to the high torque density and simplicity in their control. In this paper, the control system of the BLDC motor is developed which can be used for the micro motor handpiece, and position sensorless control is realized using back EMF measurement scheme, The validity and practical applications of the developed slotless BLDC motor and drive system are verified through the experimental results.

  • PDF

Design of Brushless DC Motor Speed Control System for Handpieces (핸드피스용 BLDC 모터 속도 제어시스템의 설계)

  • Kwak, Seong-Woo;Yang, Jung-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.6
    • /
    • pp.597-604
    • /
    • 2016
  • In this paper, we develope a speed control system of a BLDC motor for handpieces used in beauty applications. To reduce implementation cost, the control system utilizes hall sensors embedded in BLDC motors for speed estimation. The developed power module of a motor uses only 220V home voltage, so that the control system does not need any other power sources. An over-speed limit controller is also developed to slow down a motor when the speed goes up rapidly for a moment upon some heavy load is removed. The control system is designed to operate a handpiece with speed in the range of 5,000~30,000 RPM. Experiment results show the validity of the developed system, which maintains the speed of a motor steady even though a load is varied.

Study on Evaluation of Material Property of Micro Handpiece for dentistry and Surface Quality (치과용 시술기구(Micro Handpiece)재료의 특성평가 및 표면품질에 대한 연구)

  • Son, Jae-Hwan;Han, Chang-Woo;Choi, Sang-Il;Kim, Yong-Jung;Choi, Chang-Jin
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.3
    • /
    • pp.221-228
    • /
    • 2006
  • As Industrialization gets more and more advanced, human technological medical apparatus for dentistry has been developed. Such a medical apparatus have to let precision revolution and torque control facilitate. Consequently, Development of Micro hand-piece with strong durability should be required. Moreover, It's also very important to evaluate performance of such a Micro hand-piece, Evaluation of Mechanical property of Material and ANOVA have been known as useful methods in the field of Quality Evaluation. For Verification of Quality Evaluation, It has been evaluated by One-way layout ANOVA based on the data of Surface Roughness Test. Anyhow, This test has been respectively carried out by 3 kinds of Test and Superior performance has appeared in the Test result.

  • PDF

A comparative study on the user satisfaction between two different piezoelectric engines (두가지 피에조 엔진의 사용자 만족도 비교)

  • Lim, Hyun-Mi;Lee, Kyu-Bok;Lee, Wan-Sun;Choi, So-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.269-277
    • /
    • 2017
  • Purpose: The aim of this study is to compare the performance of two piezoelectric engine systems by surveying satisfaction from dental clinicians. Materials and Methods: Two piezoelectric systems were evaluated: TRAUS XUS10 (Saeshin), PIEZOSURGERY touch (Mectron). For this study, 20 dentists responded to the 11 questionnaires in which 5 point Likert-type scale was used. The two devices were operated for 10 seconds and measured 5 times to compare the maximum noise values. In heat emission test, the handpiece was operated for 3 minutes and heat was measured at three positions each. Results: TRAUS XUS10 had higher satisfaction level on motor noise (P < 0.05). About function key and handpiece heat generation, PIEZOSURGERY touch showed higher satisfaction (P < 0.05) than TRAUS XUS10. The maximum noise level for each of the devices was confirmed to be 56.6 dB for the TRAUS XUS10 and 56.0 dB for PIEZOSURGERY touch. The two piezoelectric engines satisfied the safety standards with an operation temperature below $41^{\circ}C$ after having been operated for 3 minutes. Conclusion: Except for the function key and handpiece heat emission, TRAUS XUS10 has comparable performance with PIEZOSURGERY touch.

Vibration characteristics of endodontic motors with different motion: reciprocation and conventional rotation (왕복운동 및 회전운동 근관성형용 전동모터 간의 진동 양상 비교)

  • Jeon, Yeong-Ju;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee;Chang, Hoon-Sang
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.734-743
    • /
    • 2014
  • Objectives: By introduced reciprocation motion file in dentistry, dentists benefit simple canal shaping procedure and time-saving. But, reciprocation motion generates uncomfortable vibration to doctors and patients. Because there was no study about this consideration, this study compared vibration pattern and power generated from reciprocation motion motor and conventional rotary motor. Materials & Methods: One conventional rotary motor; X-Smart (Dentsply Maillefer, Ballaigues, Switzerland); and two reciprocating motors; WaveOne Motor (Dentsply Maillefer, Ballaigues, Switzerland) and X-SMART PLUS (Dentsply Maillefer, Ballaigues, Switzerland); were used in this study. Triaxial $ICP^{(R)}$ Accelerometer (Model 356A12, PCB piezotronics, New York, USA) was attached on motor's handpiece head, and was measured tri-axial vibratory acceleration with NI Sound and Vibration Assistant 2009 software (National Instruments, Texas, USA). Mean vibratory acceleration and maximum vibratory acceleration was measured on fixed position and handed position. The results of vibratory acceleration were statistically analyzed using ANOVA and multiple comparisons are made using Turkey's test at p<0.05 level. Results: Reciprocating motors showed higher mean vibratory acceleration and maximum vibratory acceleration than conventional rotary motor (p<0.05). Between reciprocating motors, X-SMART PLUS had lower mean vibratory acceleration and maximum vibratory acceleration than WaveOne Motor (p<0.05). Conclusion: Reciprocating motors generate more vibration than conventional rotary motor. Further study about effect of vibration to dentist and patient is needed. And it seems to be necessary to make a standard about vibration level in endodontic motors.

Battery Type Surgical Handpiece Using Brushless DC Motor Drive (배터리형 외과수술용 핸드피스 브러시리스 직류 전동기 구동 드라이브)

  • Yu, Jae-Sung;Park, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.128-130
    • /
    • 2007
  • 외과수술용 핸드피스는 현재 국내 외 병원에서 사용되고 있는 수술 장비 중 필수 보유 장비이다. 선진 수술 기법인 인공관절 대체 수술 시 뼈(Bone)절단, 다듬질 구멍 등, 초 섬세 가공을 목적으로 하는 기기이다. 기존의 공압식(Air Type)은 수술 시 많은 양의 질소(N2 Gas)가 소모됨으로써 질소탱크 보관에 많은 공간이 필요하고 잦은 교체를 필요로 한다. 또한 기계소음과 공압식 호스의 이동으로 시술자와 환자사이에 불편함이 발생하고 감염의 위험성이 있으므로 최근에는 충전식을 선호하고 있다. 이러한 이유로 기존의 공압식을 대체할 배터리형 외과수술용 핸드피스를 연구하게 되었다.

  • PDF

Battery Type Surgical Handpiece Using Brushless DC Motor Drive (배터리형 외과수술용 핸드피스 브러시리스 직류 전동기 구동 드라이브)

  • Park, Sang-Hoon;Yoon, Yong-Ho;Lee, Byoung-Kuk;Won, Chung-Yuen;Jeon, Jae-Hong;An, Il-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.334-337
    • /
    • 2006
  • 외과수술용 핸드피스는 현재 국내 외 병원에서 사용되고 있는 수술 장비 중 필수 보유 장비이다. 선진수술 기법인 인공관절대체수술 시 뼈(Bone) 절단, 다듬질, 구멍등 초섬세 가공을 목적으로 하는 기기이다. 기존의 공압식(Air Type)은 수술 시 많은 양의 질소(N2 Gas)가 소모됨으로써 질소탱크 보관에 많은 공간이 필요하고 잦은 교체를 필요로 한다. 또한 기계소음과 공압식 호스의 이동으로 시술자와 환자사이에 불편함이 발생하고 감염의 위험성이 있으므로 최근에는 충전식을 선호하고 있다. 이러한 이유로 기존의 공압식을 대체할 배터리형 외과수술용 핸드피스를 연구하게 되었다.

  • PDF