• Title/Summary/Keyword: mouse abdominal connective tissue

Search Result 3, Processing Time 0.022 seconds

Comparative Biocompatibility of Metal Implants in Connective Tissue of Abdominal Wall of the Mouse (마우스의 복벽에서 결합조직에 대한 금속 이식체의 생체적합성 비교)

  • 김국렬;이민호;김병일;민병운;김명훈;최은상;조현욱
    • Toxicological Research
    • /
    • v.20 no.1
    • /
    • pp.13-20
    • /
    • 2004
  • The purpose of this study is to compare the biocompatibility of commercial purity Ti, Ti-6AI-4V and Ti-6AI-7Nb alloy specimens with and without surface treatment in mouse abdominal connective tissue in vivo. Each metal was implanted into specific abdominal subdermal tissue site of female mouse. After 4 weeks, the implants were removed and abdominal tissues were fixed, dehydrated and embedded in glycol methacrylate resin. And the tissues were histologically prepared for microscopical evaluation. It was characterized by the presence of connective tissue with fibrous capsule surrounding the implant. The fibrous tissue surrounding the implant was studied to determine the biocompatibility of implanted metals. The average thickness of the fibrous capsule formed around the implant was much thinner for the hydrogen peroxide added hydrochloric acid solution-treated specimen than for the others. The results of this evaluation indicate that modification of the surface properties of titanium and titanium alloy implants changes the biological properties in the abdominal connective tissue. In conclusion, these observations suggest that the proper surface treatment performed in the study is effective for the improvement of biocompatibility.

Evaluation of Bioactivity of Titanium Implant Treated with H2O2/HCl Solution (H2O2/HCl 처리한 Ti 임플란트의 생체활성 평가)

  • Yue J. S.;Kwon O. S.;Lee O. Y.;Lee M. H.;Song K. H.
    • Korean Journal of Materials Research
    • /
    • v.15 no.5
    • /
    • pp.353-360
    • /
    • 2005
  • Surface treatment play an important role in nucleating calcium phosphate deposition on surgical Ti implant. Therefore, the purpose of this study is to examine whether the precipitation of apatite on cp-Ti and Ti alloys are affected by surface modification in HCl and $H_2O_2$ solution. Specimens were then chemically treated with a solution containing 0.1 M HCl and 8.8M $H_2O_2$ at $80^{\circ}C$ for 30 mins, and subsequently heat-treated at $400^{\circ}C$ for 1 hour. All specimens were immersed in the HBSS with pH 7.4 at $36.5^{\circ}C$ for 15 days, and the surface was examined with XRD, SEM, EDX ana XPS. Also, pure Ti, Ti-6Al-4V and Ti-6Al-7Nb alloy specimens with and without surface treatment were implanted in the abdominal connective tissue of mice for 4 weeks. All specimens chemically treated with HCl and $H_2O_2$ solution have the ability to form a apatite layer in the HBSS which has inorganic ion composition similar to human blood plasma. The average thickness of the fibrous capsule surrounding the specimens implanted in the connective tissue was $38.57\;{\mu}m,\;62.27\;{\mu}m\;and\;45.64\;{\mu}m$ in the cp-Ti, Ti-6Al-4V ana Ti-6Al-7Nb alloy specimens with the chemical treatment respectively, and $52.20\;{\mu}m,\;75.62\;{\mu}m\;and\;66.56\;{\mu}m$ in the commercial specimens of cp-Ti, Ti-6Al-4V and Ti-6Al-7Nb without any treatment respectively. The results of this evaluation indicate that the chemically treated cp-Ti, Ti-6Al-4V ana Ti-6Al-7Nb alloys have better bioactivity and biocompatibility compared to the other metals tested.

Relative Biocompatibility Evaluation of Anodized Titanium Specimens in vivo and in vitro (In vivo와 in vitro 에서 양극산화 처리한 타이타늄 시편의 상대적인 생체적합성 평가)

  • Lee Yu-Mi;Lee Eun-Jung;Yeom Dong-Sun;Kim Do-Soon;Yee Sung-Tae;Kim Byung-Il;Cho Hyun-Wook
    • Journal of Life Science
    • /
    • v.16 no.2 s.75
    • /
    • pp.302-309
    • /
    • 2006
  • To evaluate the biocompatibility of untreated and anodized titanium specimens, the specimens were implanted in the subcutaneous tissue of the abdominal region of female mice for two weeks. The reaction of connective tissue to specimens was histologically studied. The implants were encapsulated by fibrous connective. tissue consisting of fibroblast, fibrocyte and other cellss including neutroophil, macrophage and giant multinucleated cell. some newly formed blood vessels were located in the fibrous capsule surrounding the implant. Giant multinucleated cells were observed at the fibrous capsule adjacent to the implant. Kind of cell types and the thickness of fibrous capsules were examined quantitatively. Most of cell types located in the fibrous capsule were fibroblast and fibrocyte. The average thickness of fibrous capsules for the anodized specimens was much thinner than that of the untreated titanium specimen. Biocompatibility of titanium specimens were also studied by using cell culture method. The number of MG-63 cells was significantly increased on the anodized titanium specimens in vitro experiment. Our observations suggest that anodized titanium specimens are more effective for the improvement of biocompatibility in vivo and in vitro.