• Title/Summary/Keyword: multistage procedures

Search Result 8, Processing Time 0.029 seconds

A Note on Comparing Multistage Procedures for Fixed-Width Confidence Interval

  • Choi, Ki-Heon
    • Communications for Statistical Applications and Methods
    • /
    • v.15 no.5
    • /
    • pp.643-653
    • /
    • 2008
  • Application of the bootstrap to problems in multistage inference procedures are discussed in normal and other related models. After a general introduction to these procedures, here we explore in multistage fixed precision inference in models. We present numerical comparisons of these procedures based on bootstrap critical points for small and moderate sample sizes obtained via extensive sets of simulated experiments. It is expected that the procedure based on bootstrap leads to better results.

A note on the sample size determination of sequential and multistage procedures

  • Choi, Kiheon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.23 no.6
    • /
    • pp.1279-1287
    • /
    • 2012
  • We particularly emphasized how to determine the number of replications with sequential and multistage procedures. So, the t-test is used to achieve some predetermined level of accuracy efficiently with loss function in the case of normal, chi-squared, an exponential distributions. We provided that the relevance of procedures are sequential procedure, two-stage procedure, modified two-stage procedure, three-stage procedure and accelerated sequential procedure. Monte Carlo simulation is carried out to obtain the stopping sample size that minimizes the risk.

Development of Multistage Roots Dry Vacuum Pump Technology (다단 루츠 드라이 진공펌프 기술 개발)

  • Ryu, Jae-Kyeong
    • Vacuum Magazine
    • /
    • v.2 no.4
    • /
    • pp.39-46
    • /
    • 2015
  • After stepping into a new field of vacuum 30 years ago, our company has grown up steadily as a specialized vacuum industry, and now we can provide vacuum devices covering most of the pressure range. We are planning to put out high level dry pump like a multistage Roots pump on the market in the near future. Procedures of technology development for designing, fabricating, and testing the multistage Roots pump of 600 L/min class will be briefly reported. Core items of the technical development on the multistage Roots pump are as follows; elaborated profile design of 3-lobe rotors using an involute curve, optimization of rotor dimensions, especially for clearances and rotor width, considering the pumping speed, compression ratio and heat load, and establishment of a standardized test system. At present, the multistage Roots pump is about to come into commercialization.

Development of a Simulation Method of Surge Transient Flow Phenomena in a Multistage Axial Flow Compressor and Duct System

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.4
    • /
    • pp.189-199
    • /
    • 2013
  • A practical method of surge simulation in a system of a high-pressure-ratio multistage axial flow compressor and ducts, named SRGTRAN, is described about the principal procedures and the details. The code is constructed on the basis of one-dimensional stage-by-stage modeling and application of fundamental equations of mass, momentum, and energy. An example of analytical result on surge behaviors is included as an experimental verification. It will enable to examine the transient flow phenomena caused by possible compressor surges and their influences on the system components in plant systems including high-pressure-ratio axial compressors or gas turbines.

A Study for Time Standard Estimation with Activity Sampling Method (가동샘플링기법에 의한 표준시간추정에 관한 연구)

  • 이근희
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.6 no.9
    • /
    • pp.1-5
    • /
    • 1983
  • This study takes over the application of survey sampling theory to activity sampling and the application of activity sampling to time standard estimation. Cluster, stratified, and multistage sampling are studied in conjunction with random and systematic sampling. Estimation procedures that will maximize the information obtained per cost expended on the study and specification of the procedure to be used to estimate the accuracy of the estimates for the adopted procedure are considered. The use of multiple regression md linear programming to estimate standard element performance time from typical job lot production data is also considered.

  • PDF

A Fast and Sensitive Method for the Simultaneous Determination and Quantification of Six Anionic Surfactants in Surface Water using HILIC-ESI-MS Technique

  • Dash, Upendra N.;Paul, Saroj Kumar
    • Mass Spectrometry Letters
    • /
    • v.3 no.3
    • /
    • pp.78-81
    • /
    • 2012
  • The hydrophobic hydrocarbon chain and the polar sulfate group confer surfactant properties and enable them to be used as anionic surfactants. Anionic surfactants (AS) are known for their adverse impact on environment, particularly on aquatic ecosystem. In the present study a fast, sensitive and selective method for the determination and subsequent quantification of six anionic surfactants was developed using hydrophilic interactive liquid chromatography (HILIC) coupled to a electrospray ionization (ESI) mass spectrometer (MS), in the concentration range 15-20 ${\mu}g/L$. The capability of the method was established using regression analysis and ANOVA. The method performance was evaluated by analyzing real time surface water spiked with 1-dodecyl hydrogen sulfate at 15 ${\mu}g/L$. Combined efficiency of solid phase extraction and MS detection established recovery of 89% in presence of natural matrix. These results point out that HILIC coupled to multistage MS procedures can be a powerful technique for environmental applications concerning the screening of polar contaminants.

Development of an In Situ Direct Shear Test Apparatus and Its Field Application (현장직접전단시험기의 개발 및 현장적용에 관한 연구)

  • Kim, Yong-Phil;Lee, Young-Kyun;Lee, Sung-Kook;Um, Jeong-Gi
    • Tunnel and Underground Space
    • /
    • v.21 no.3
    • /
    • pp.181-191
    • /
    • 2011
  • It is very difficult to prepare a lab. test specimen from weak rock masses affected by faults, highly fractured zone or weathered zone. In conventional method of in situ direct shear test a rock block is sheared inside galleries, where reactions for the hydraulic jacks are available. A new in situ direct shear test apparatus has been developed in this study to perform the test inside galleries as well as open pit conditions. The apparatus is composed of normal and shear reaction plates including load transfer plates, hydraulic cylinder systems, load cells, multistage shear boxes with fixing devices, and needle rollers. Maximum size of the test block is $400{\times}400{\times}460$ mm, and procedures of the test block preparation has been suggested. To explore the field applicability of in situ direct shear test apparatus, proper test block site was investigated by extensive geological field survey. In situ direct shear test has been successful in producing most of information related to strength and deformability of the weak rock.

Performance Evaluation of Networks with Buffered Switches (버퍼를 장착한 스위치로 구성된 네트워크들의 성능분석)

  • Shin, Tae-Zi;Nam, Chang-Woo;Yang, Myung-Kook
    • Journal of KIISE:Information Networking
    • /
    • v.34 no.3
    • /
    • pp.203-217
    • /
    • 2007
  • In this paper, a performance evaluation model of Networks with the multiple-buffered crossbar switches is proposed and examined. Buffered switch technique is well known to solve the data collision problem of the switch networks. The characteristic of a network with crossbar switches is determined by both the connection pattern of the switches and the limitation of data flow in a each switch. In this thesis, the evaluation models of three different networks : Multistage interconnection network, Fat-tree network, and other ordinary communication network are developed. The proposed evaluation model is developed by investigating the transfer patterns of data packets in a switch with output-buffers. Two important parameters of the network performance, throughput and delay, are evaluated. The proposed model takes simple and primitive switch networks, i.e., no flow control and drop packet, to demonstrate analysis procedures clearly. It, however, can not only be applied to any other complicate modern switch networks that have intelligent flow control but also estimate the performance of any size networks with multiple-buffered switches. To validate the proposed analysis model, the simulation is carried out on the various sizes of networks that uses the multiple buffered crossbar switches. It is shown that both the analysis and the simulation results match closely. It is also observed that the increasing rate of Normalized Throughput is reduced and the Network Delay is getting bigger as the buffer size increased.