• Title/Summary/Keyword: needle electrode

검색결과 252건 처리시간 0.025초

대전된 절연유에 의한 제전관내 침전극의 전위변화에 관한 연구 (The Study on the Electric Potential Variation of Needle Electrodes by Charged Insulating Oil in the Charge Reducer)

  • 김영일;김영봉;김두석;박재윤;조영규;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1583-1585
    • /
    • 1994
  • In this paper, we investigated the relationship between the needle electrode current and the needle electrode potential, The needle electrode potentials have influence on the needle electrode currents absolutely. So, to increase the needle electrode currents there is necessary to keep a high electric field if the charge reducer. for this, high insulation materials must be selected, and charge density of insulating oil must be high. In this experiment, the more a charge density of insulating oil increases, the more a needle electrode potential increases. So we could know what increasement of needle electrode potential increases a needle electrode current.

  • PDF

관형 코로나 방전전극을 이용한 이온풍속의 최대화 (An Maximization of Ionic Wind Utilizing a Cylindrical Corona Electrode)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2256-2261
    • /
    • 2010
  • A corona discharge system with needle point or wire type corona electrode has been well used as an ionic wind blower. The corona discharge system with a needle point electrode produces ions at lower applied voltage effectively. However, the corona discharge on the needle point electrode transits to the arc discharge at lower voltage, and it is hard to obtain the elevated electric field in the discharge airgap for enhancing the ion migration velocity due to the weak Coulomb force. A cylindrical corona electrode with sharp round tip is reported as one of effective corona electrode, because of its higher breakdown voltage than that of the needle electrode. A basic study, for the effectiveness of cylindrical electrode shape on the ionic wind generation, has been investigated to obtain an maximum wind velocity, which however is the final goal for the real field application of this kind ionic wind blower. In this paper, a parametric study for maximizing the ionic wind velocity utilizing the cylindrical corona electrode and a maximum ion wind velocity of 4.1 m/s were obtained, which is about 1.8 times higher than that of 2.3m/s obtained with the needle corona electrode from the velocity profile.

웨이블렛변환을 이용한 부분방전 종류의 특징추출에 관한 연구 (A Study on Feature Extraction of Partial Discharge Type Using Wavelet Transform)

  • 박재준
    • 정보학연구
    • /
    • 제6권1호
    • /
    • pp.65-70
    • /
    • 2003
  • 본 논문에서 우리는 변압기의 부분방전형태를 진단하기위하여 새로운 방법을 제시하였다. 웨이블렛 변화을 위하여, 다우비치 필터가 사용되어졌다. 우리는 3개의 전극 종류(침대평판자극, IEC전극, 보이드 전극)마다 고주파 전류신호에 관한 통계적인 특징 파라메터(최대값, 평균값, 분산, 왜도, 첨쇄도)를 추출하기위하여 사용하였다. 역시 이들 계수들은 변압기내 내부부분방전의 신호의 정체를 알기위하여 사용되어졌다. 그 결과로서 고주파전류신호의 진폭과 평균값의 비교로부터 우리는 IEC electrode> Void electrode> Needle-Plane electrode의 결과를 얻었다. 반면에 왜도와 첨쇄도의 경우, 우리는 Void electrode> IEC electrode> Needle-Plane electrode을 얻었다.

  • PDF

금속관형 코로나 방전극을 적용한 효과적인 이온풍 발생 (Effective Ionic Wind Generation Utilizing a Cylindrical Corona Discharge Electrode)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.599-603
    • /
    • 2010
  • A point-mesh type corona system has been well used as a ionic wind blower. However this type corona system suffers from its lower ionic wind generation, because of its lower on-set and breakdown voltages of its very sharp needle point corona electrode. This means that the point corona electrode must act both as an effective ion-generator and a very higher electric field producer in the discharge airgap in order to generate higher ionic wind velocity. In this paper, a cylinder-mesh type discharge system as a ionic wind generator is proposed and investigated. The cylindrical corona electrode can produce many ions from its sharpened edge, and the corona on-set and breakdown voltages are very higher than those of the needle point corona electrode. As a result, this type cylindrical corona electrode might generate a higher ionic wind than the needle point corona electrode.

전극형상 및 보이드에 따른 XLPE의 부분방전 특성 (Partial Discharge Characteristics of XLPE According to Electrode Shape and Void)

  • 신종열;김균식;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제29권1호
    • /
    • pp.50-57
    • /
    • 2016
  • Transmission equipment is mainly used for the XLPE (cross-linked polyethylene) insulation cable for ultra high voltage power to minimize power loss. The experiment examined the partial discharge characteristics according to the insertion of the bar electrode and needle electrode into the XLPE specimen and the air voids. XLPE insulation cable manufactured by T. company and tungsten electrode material by K. company were used for specimens, by adhering conductive tape on the semi-conductive material of the lower electrode of XLPE specimen with the dimension of $16{\times}40{\times}30$ [mm] was used as negative electrode. In order to investigate the PD with ${\phi}$-q-n of XLPE specimen according to the electrode shape and the size of air voids. we examined the PD by varying the voltage after applying voltage of 3~20 kV on the electrode. Therefore, it was confirmed from the result of PD characteristics of specimen that the larger the air void than the gap between electrode (+) and electrode(-), the larger effect on the discharge when the bar electrode and needle electrode inserted into XLPE, and the closer the distance between the insulation and the needle electrode, the faster insulation breakdown.

전계 제어형 정전하 중화장치 (Field Control Type Electrostatic Charge Neutralizer)

  • 정석환;이대희;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권6호
    • /
    • pp.469-474
    • /
    • 1999
  • Methods and systems to remove static electricity are requested in the field of industry because the static electricity causes a flammable gas explosion or fire and a reduction of production rate in manufacturing semiconductor devices and so on. This paper is a basic study about a new structure of electrode system to control the quantities of generated ions and to solve the problem of dust attachment to needle electrode. In addition, a new type field controlled electrostatic charge neutralizer was proposed, and it could control the electric field in the end of the needle electrode by controlling the voltage of the third electrode around the tip of the needle electrode. As aresult, it was possible to control the quantities of generated ion by controlling the electric field in the needle electrode with the third electrode, which shows the possibilities to solve the nonequilibrium of generated ions in ac power source and the problem of the dust in the needle electrode.

  • PDF

침 전극을 이용한 전하 주입과 유동대전 감소 특성 (Charge Injection by Needle Electrode and Reduction Properties of Streaming Electrification)

  • 김용운;이덕출;강창원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.108-112
    • /
    • 2000
  • The electric charge generated by flowing insulation liquid can create hazardous spark in transfer line and receiving tank etc. These electrification has generally been measured by current measurement with a ammeter connected to the receiving tank. This paper reports on the experimental result obtained by this method. As a experimental results: The injected charge value for unit volume increased in the following condition, the edge of the needle electrode was sharp, the number of needle electrode was fewer, the edge of the needle electrode was located close to the inside wall. When the charge density in the charge reducer is constant, electrode current and electrode potential by the charge injection from outside increase with increasing of oil velocity and streaming current. The electrode potential in charge reducer is made maximum value at edge point of reducer inside and minimum value at center line of charge reducer.

  • PDF

침 전극 기울기에 따른 XLPE의 부분 방전 특성 (The Partial Discharge Characteristics of the XLPE According to the Tilt of the Needle Electrode)

  • 신종열;안병철;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.28-33
    • /
    • 2015
  • The needle electrode is inserted into the cross-linked polyethylene(XLPE) which is the ultra high voltage cable for electric power. By changing the tilt of the needle electrode, we investigated how the void and the thickness of the insulating layer influence the partial discharge(PD) characteristics and the insulating breakdown. In order to investigate the PD characteristics, The XLPE cable was used to the specimens and the tungsten electrode was used with the needle electrode. And the inner semi-conductive layer material of XLPE cable was used with the negative electrode by bonding with the use of conduction tape. The size of the specimens was manufactured to be $16{\times}40{\times}30[mm^3]$. We confirmed the effect on changing the PD characteristics according to the changing voltage and the tilt of the electrode after applying the voltage on the electrode from 1[kV] to 40[kV] at room temperature. In the PD characteristics, it was confirmed that the PD current of air void specimens with tilt was unstable more than that of no void specimens with tilt. It was also confirmed that the breakdown voltage was decreased because the effect of air void is more active than the change of the needle electrode tilt in the specimen with air void inside the insulation.

침 전극에 의한 초고압 케이블 절연재료의 부분방전 특성 (Partial Discharge Characteristics of Ultra-High Voltage Cable Insulators by Needle Electrode)

  • 김균식;최범규;변두균;조경순;김귀열;이충호;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.477-480
    • /
    • 2004
  • In other to estimate an electrical properties of the cross linked polyethylene cable, the partial discharge properties due to charge of electrode shape(needle and bar) and void size were investigated at room temperature. Fast trip and breakdown time were appeared by the closed of needle electrode. The trip and breakdown voltage depend on insulator thickness. As the result, confirmed larger effect of void size than effect of insulator thickness. The effect of voids size than influence of insulation thickness was dominated by internal an electrode of inner insulators.

  • PDF

외이에 적용한 침전극저주파치료가 흡연 및 비흡연 요통 환자에게 미치는 효과 (The Effects of the Needle Electrode Electrical Stimulation in the Auricular Therapy on the smokers and non-smokers with Low Back Pain)

  • 민경옥;김순희;박수진
    • 대한물리치료과학회지
    • /
    • 제9권1호
    • /
    • pp.45-52
    • /
    • 2002
  • This study was intended to observe the relationship of pain alleviation between the group with needle electrode electrical stimulation applied on bach of head, lung, nasalis internae, shen-men, pharynx & larynx, and internal secretion which are the pants to regulate smoking and that, with no treatment of the kind among smokers and con-smokers with chronic low back pain. It also aimed to conduct a research of applying different treatment methods according to smoking, thus ultimately providing basic data needed by clinic therapists and to help achieve appropriate treatment effects considering the characteristics of each patient. The subject criteria were men who were in their 40's or 50's, smoking or non-smoking and came to the physical therapy of the hospital to cure the chronic low back pain which had lasted more than three months. The total 24 subjects were randomly divided into four groups according to smoking; the group of smokers with needle electrode electrical stimulation applied, that of smokers with no application of such treatment, that of non-smokers with the action of such treatment, and that of non-smokers with no application of such treatment Each group was measured in terms of four pain assessment methods of visual analogue scale(VAS), verbal rating scale(VRS), McGil pain questionnaire(MPQ), endorphin. And the results were as follows: 1. In terms of the effects of the needle electrode electrical stimulation in the auricular therapy on pain had by the smokers with low back pain, there was a statistical significance in VAS, VRS, and endorphin 1 between before and after the treatment. 2. In terms of the pain effects had by the smokers with low back pain when no needle electrode electrical stimulation in the auricular therapy was applied, there was a statistical significance in VRS and MPQ between before and after the treatment. 3. In terms of the effects of the needle electrode electrical stimulation in the auricular therapy on pain had by the non-smokers with low back pain, there was a statistical significance in VAS, VRS, and MPQ between before and after the treatment. In terms of the pain effects had by the non-smokers with low back pain when no needle electrode electrical stimulation in the auricular was applied, there was a statistical significance in VAS, VRS, and MPQ between before and after the treatment. 5. The smokers with low back pain were given the needle electrode electrical stimulation in the auricular therapy to see how it affected their pain. There was found pain reduction in number, but no statistical significance. 6. The subject suffering from low back pain were given the needle electrode electrical stimulation to see how it affected their pain according to smoking. There was found pain reduction in number, but no statistical significance. Based upon the results, it can be concluded that smokers with low back pain received the more effects of pain alleviation from the application of the needle electrode electrical stimulation in the auricular therapy compared to the rest of the groups who suffered from low back pain.

  • PDF