• Title/Summary/Keyword: non-vacuum

Search Result 626, Processing Time 0.049 seconds

A Study of Non-uniform Pressure Distribution in Vacuum Chamber during Dynamic Gas Flow (기체유입이 되는 진공챔버 안의 불균등한 압력분포 연구)

  • Khan, Wakil;Hong, K.S.;Hong, S.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.6
    • /
    • pp.403-410
    • /
    • 2009
  • Vacuum chambers have wide application for a variety of purposes such as material processing, vacuum gauge calibration, etc. As the dynamic pressure generated in such chamber is non-uniform, in many industrial as well as research processes, it is vital to know the non-uniform gas distribution with associated gas flow regimes and the ways of minimizing these pressure non-uniformities. In the present work, the behavior of gas flow in a vacuum chamber, during continuous gas flow, is described in the pressure range 0.1-133 Pa and the effect of baffle plate in minimizing the pressure non-uniformities is investigated. It was observed that maximum deviations in the pressure occur near the gas inlet point and that the effect of baffle plate in minimizing the pressure non-uniformities is more obvious in the transitional flow regime.

Development of a Housing Component for an Auto-compressor Using Vacuum Ladling Die Casting (진공급탕식 다이캐스팅법을 이용한 자동차 콤프레서용 하우징 부품 개발)

  • Lee, H.S.;Park, J.S.
    • Transactions of Materials Processing
    • /
    • v.21 no.3
    • /
    • pp.195-201
    • /
    • 2012
  • A vacuum ladling die casting system is suggested as a means to obtain a high vacuum level. A high vacuum of 17.8 mmHg is obtained by sealing the inner space of the mould. The sample product is a rear-head housing for an auto-compressor, and the die-casting with 6-cavities was conducted. The flow analysis shows that the filling speed during vacuum ladling is faster than for a non-vacuum system. The air holes in the sample product were too small to be seen with the naked eye in X-ray films. Density tests show that the high vacuum ladling system reduces the internal porosity as much as 57.8% when compared to the non-vacuum system. A defective rate of only 0.17% was found from leak testing. The results of this research prove that the high vacuum die-casting process is useful for manufacturing of aluminium components under high internal pressure.

The Processing of Seasoned and Fermented Oyster and Its Qulaity Changes during the Fermentation (굴 조미 젓갈 제품의 숙성 중 품질 변화에 관한 연구)

  • Lee, Heon-Ok;Rhee, Seong-Kap;Lee, Seong;Kim, Dong-Soo
    • Applied Biological Chemistry
    • /
    • v.44 no.2
    • /
    • pp.81-87
    • /
    • 2001
  • Oyster jeot-gal were prepared in the form of salt-fermented oyster and oyster in soy sauce tentatively and used for investigation the retarding effect of its fermentation in a vacuum from the physicochemical and microbiological points of view. $_PH$ value decreased slightly but amino-N (AN) and volatile basic nitrogen (VBN) increased inversely during the fermentation periods. AN contents were greater in vacuum fermentation than in non-vacuum, whereas VBN were greater in non-vacuum. Total viable cell counts were similar to trend of gentle decrement after increment to some degree but showed higher in non vacuum than in vacuum. In vacuum product, total amino acid contents increased with the elapse of fermentation days or in time of reduction those were higher than in non-vacuum. On the results of chemical analysis, it showed that fermentation was delayed in vacuum and that vacuum fermentation was effective for the shelf-life extension of jeot-gal.

  • PDF

Design and Fabrication of a Vacuum Chamber for a Commercial Atomic Force Microscope

  • Park, Sang-Joon;Jeong, Yeon-Uk;Park, Soyeun;Lee, Yong Joong
    • Applied Science and Convergence Technology
    • /
    • v.23 no.2
    • /
    • pp.97-102
    • /
    • 2014
  • A vacuum chamber for a commercial atomic force microscope (AFM) is designed and fabricated. Only minimal modifications were made to an existing microscope in an effort to work in a vacuum environment, while most of the available AFM functionalities were kept intact. The optical alignment needed for proper AFM operations including a SLD (superluminescent diode) and a photodiode can be made externally without breaking the vacuum. A vacuum level of $5{\times}10^{-3}$ torr was achieved with a mechanical pump. An enhancement of the quality factor was observed along with a shift in the resonance frequency of a non-contact-mode cantilever in a vacuum. Topographical data of a calibration sample were also obtained in air and in a low vacuum using the non-contact mode and the results were compared.

Fabrication of CIGS/CZTS Thin Films Solar Cells by Non-vacuum Process (비진공 방법에 의한 CIGS/CZTS계 박막 태양전지 제조)

  • Yoo, Dayoung;Lee, Dongyun
    • Korean Journal of Materials Research
    • /
    • v.28 no.12
    • /
    • pp.748-757
    • /
    • 2018
  • Inorganic semiconductor compounds, e.g., CIGS and CZTS, are promising materials for thin film solar cells because of their high light absorption coefficient and stability. Research on thin film solar cells using this compound has made remarkable progress in the last two decades. Vacuum-based processes, e.g., co-evaporation and sputtering, are well established to obtain high-efficiency CIGS and/or CZTS thin film solar cells with over 20 % of power conversion. However, because the vacuum-based processes need high cost equipment, they pose technological barriers to producing low-cost and large area photovoltaic cells. Recently, non-vacuum based processes, for example the solution/nanoparticle precursor process, the electrodeposition method, or the polymer-capped precursors process, have been intensively studied to reduce capital expenditure. Lately, over 17 % of energy conversion efficiency has been reported by solution precursors methods in CIGS solar cells. This article reviews the status of non-vacuum techniques that are used to fabricate CIGS and CZTS thin films solar cells.

Effect of Vacuum in a Non-glass Vacuum Tube on the thermal behavior of the Absorber Plate (비유리식(nonglass) 진공관의 진공도가 집열판의 열적 특성에 미치는 영향)

  • Oh, Seung-Jin;Hyun, Jun-Ho;Kim, Nam-Jin;Lee, Yoon-Joon;Chun, Won-Gee
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.67-73
    • /
    • 2008
  • This study has been carried out to investigate the effect of vacuum on the thermal performance of a nonglass evacuated tube. A series of measurements are made indoors to monitor the temperature change of the absorber plate contained in the evacuated tube under different conditions of vacuum and heat fluxes. Those temperatures measured at the thermal equilibrium could be used to assess the heat losses to the ambient in link with the steady operation of non-glass evacuated tubes for solar exploitation.

Surgical versus Vacuum Bell Therapy for the Correction of Pectus Excavatum: A Comparison of 1-Year Treatment Outcomes

  • Jung, Younggi;Yi, Eunjue;Lee, Kwanghyoung;Chung, Jae Ho;Cho, Seonghyun;Lee, Sungho
    • Journal of Chest Surgery
    • /
    • v.54 no.6
    • /
    • pp.473-479
    • /
    • 2021
  • Background: The purpose of this study was to compare 1-year clinical outcomes between patients who underwent a Nuss operation or vacuum bell therapy and to present vacuum bell therapy as a possible alternative treatment modality for patients who prefer non-surgical correction of pectus excavatum. Methods: We conducted a retrospective review of pectus excavatum patients who had undergone vacuum bell therapy for more than 1 year and examined patients who had undergone Nuss bar removal more than 1 year previously. The treatment outcomes were evaluated by comparing changes in the Haller index before and after treatment in both patient groups. Results: We included 57 patients in this study and divided them into 2 groups according to the type of treatment received. Both groups showed no significant difference in the post-treatment Haller index after 1 year of follow-up, although the Nuss operation group showed a greater change in the Haller index than the vacuum bell group. Conclusion: Although the Nuss operation is a well-established and effective treatment of choice to correct pectus excavatum, vacuum bell therapy showed comparable outcomes and could become an alternative treatment modality for select patients who prefer non-invasive treatment.