• Title/Summary/Keyword: outdoor insulator

Search Result 102, Processing Time 0.035 seconds

A Prediction on the Pollution Level of Outdoor Insulator with Regression Analysis (회귀분석을 활용한 옥외 절연물의 오손도 예측)

  • 최남호;구경완;한상옥
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.3
    • /
    • pp.137-143
    • /
    • 2003
  • The degree of contamination on outdoor insulator is ons of the most importance factor to determine the pollution level of outdoor insulation, and the sea salt is known as the most dangerous pollutant. As shown through the preceding study, the generation of salt pollutant and the pollution degree of outdoor insulator have a close relation with meteorological conditions, such as wind velocity, wind direction, precipitation and so fourth. So, in this paper, we made an investigation on the prediction method, a statistical estimation technique for equivalent salt deposit density of outdoor insulator with multiple linear regression analysis. From the results of the analysis, we proved the superiority of the prediction method in which the variables had a very close(about 0.9) correlation coefficient. And the results could be applied to establish the Pollution Prediction System for power utilities, and the system could provide an invaluable information for the design and maintenance of outdoor insulation system.

Influence upon electrical properties of outdoor insulators with non-uniformity contamination (국부오손이 옥외절연물의 전기적 특성에 미치는 영향)

  • 이원영;최남호;박강식;한상옥
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.203-206
    • /
    • 2001
  • Since th three sides of korea peninsula are surrounded by the sea, electric apparatus are greatly contaminated by the salt generated by the typhoon, seasonal wind, sea wind and sea fog. This contamination causes electric power apparatus to fail. Thus in this paper, we investigated to influence upon electrical properties of outdoor insulators with non-uniformity contamination in the experimental condition because The contamination of outdoor insulator highly depended wind property In the service condition, insulator was not uniformly contaminated. From the flashover test for the 254 mm suspension insulator, we could determine the influence non-uniform contamination on the electrical property of insulators. Through the experiment, we convinced to occur flashover from non-uniform contamination region of outdoor insulator. Contaminated area and pattern has a close relationship with the electrical properties of outdoor insulator.

  • PDF

A Study on Measurement of ESDD and Contamination Performance of Polymeric Outdoor Insulators (옥외용 절연체 표면에서의 ESDD 측정과 내오손특성에 관한 연구)

  • 연복희;유형철;이현진;송정용;이태호;허창수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.427-430
    • /
    • 2002
  • This paper presents on contamination performance of polymeric outdoor insulator with different contaminant accumulation. The ESDD (equivalent salt deposit density), tracking resistance and clean-fog test were performed to investigate the characteristics of contamination performance on polymeric outdoor insulator. Furthermore, we evaluated together with the porcelain samples for its comparison. It is found that ESDD of polymeric and porcelain insulator depends on the installation position. This surface accumulation of contaminant lead to the loss of surface hydrophobicity, expecially upper shed part of polymeric insulator. In addition, the effect of an artificial contaminant on the tracking resistance by inclined-plane method and leakage suppression ability under clean fog was surveyed. The time of tracking failure did not appear to change significantly with a much contaminant accumulation, while leakage current under clean-fog increased.

  • PDF

Leakage Current Properties Analysis of Outdoor Insulator on Climatic.Environmental Factor (기후.환경 인자에 의한 옥외 절연물의 누설전류 특성 분석)

  • Lee, Won-Yeong;Shim, Kyu-Il;Han, Sang-Ok;Park, Gang-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.27-30
    • /
    • 2002
  • In this paper, we were investigated leakage current properties of outdoor insulator on climatic environmental factor. Contamination is one of the most important factor to determine the performance of insulator. Thus, it is very important to exam the contamination degree on the outdoor insulator. There are many limits, such as reliability of data, interval of measurement and similarity of environmental conditions, in conventional method. So, we measured phase and leakage current of outdoor insulator using the temperature & humidity chamber. In this investigation, phase difference was measured to compare the variance of phase difference with the contamination degree and relative humidity.

  • PDF

Contamination and Climate Properly Analysis of Outdoor Insulator by DB Model (DB 분석을 통한 옥외 절연물의 오손 및 기후특성 분석)

  • Kim, Do-Young;Kim, Jae-Hoon;Lee, Won-Young;Park, Doo-Ki;Han, Sang-Ok;Park, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1832-1834
    • /
    • 2004
  • The degree of contamination on outdoor insulator is one of the most importance factors to determine the pollution level of outdoor insulations, and the sea salt is known as the most dangerous pollutant. As shown through the preceding study, the generation of salt pollutant and the pollution degree of outdoor insulator have a close relation with meteorological conditions, such as wind velocity, rainfall, and so on. So, in this paper, we have made database using the past meteorological data and ESDD(equivalent salt deposit density) and then we predicted the pollution degree in the future after analyzing currently meteorological data of database.

  • PDF

Durability and Evaluation of Plastic Insulator for the Outdoor (옥외용 프라스틱 애자의 내구성과 평가)

  • 조한구;강동필;한동희;김인성
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1993.10a
    • /
    • pp.97-102
    • /
    • 1993
  • The application of epxy composite materials for the outdoor insulating systems has some significant advan-tages compared with conventional inorganic materials, that is low weight in combination with high mechanical strength, small dimensions and design versatility. The paper describes the results of high voltage investigations carried out different aging types of epoxy resin insulator and silicone grease coating. The insulators have been exposed 3000 hours to weather-o-meter and 12 months to outdoor. In this connection, the main study of paper is form the basis of develop-ment of principal technologies of epoxy composites which ard: (1)manufacturing of insulator, (2)high vol-tage testing under dry and wet condition, (3)mechani-cal properties, (4)accelerated weather-ometer test and outdoor exposed, artificial polution.

  • PDF

Properties of Surface Electrical Conduction in Materials for Outdoor Insulator (옥외 애자용 재료의 표면 전기전도특성)

  • 박영국;강성화;정수현;이운석;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.207-210
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition. The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

Electrical Conduction Properties of Surface in Materials for Outdoor Insulator (옥외 애자용 재료의 표면 전기전도 특성)

  • 박영국;이운석;정수현;장동욱;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.758-762
    • /
    • 1998
  • Electrical conduction property of insulator surface is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the materials to be used for outdoor insulator such as porcelain, EPDM, silicone rubber was discussed by measuring properties of average leakage current and scintillation discharge pulses under salt fog conditions. The fog was applied by nozzle in chamber and fogging fluids were deionized distilled water, 0.5wt% NaCI solution and 2wt% NaCl solution. The average leakage current showed linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage were much different to those in case of dry and clean condition with 2wt% salt fog. In case of slat fog pollution condition, the leakage current was increased above critical voltage. the scintillation discharges were also activated at the level. The leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

Estimation of Pollution Degree for Liveline Insulator with Leakage Current Measurement (누설전류 측정을 통한 활선 절연물의 오손도 추정)

  • Shim, Kyu-Il;Choi, Nam-Ho;Park, Kang-Sik;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1472-1474
    • /
    • 2001
  • In this paper, a method was presented to estimate the contamination degree of outdoor insulator by the measurement of surface leakage current. Contamination is one of the most important factor to determine the performance of insulator. Thus, it is very important to exam the contamination degree on the outdoor insulator. There are many limits, such as reliability of data, interval of measurement and similarity of environmental conditions, in conventional method. So, the estimation technique for contamination has been needed to monitor the accurate pollution degree of insulator in situ. In this investigation, phase difference was measured to compare the variance of phase difference with the contamination degree and relative humidity. From the result, we could confirm the capability of the estimation method.

  • PDF

Leakage Current Waveforms of Outdoor Polymeric Insulators and Possibility of Application for Diagnostics of Insulator Conditions

  • Suwarno Suwarno
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.114-119
    • /
    • 2006
  • This paper reports the investigation results on the leakage currents (LC) on polymeric outdoor insulators. The samples used were EPDM (ethylene prophylene diene monomer) insulators used at 20 kV distribution lines. AC voltage was applied and the LC waveforms were measured under various environmental conditions (humidity and pollution). Digital data of the LC was transferred from a digital storage oscilloscope to a computer for further analysis. The LC waveform parameters such as magnitude and harmonic content (as indicated by the total harmonic distortion (THD)) were analyzed. The experimental results showed that 3rd, 5th and 7th harmonics and higher odd harmonics were observed for symmetrical-distorted LC waveforms while for unsymmetrical-distorted LC waveforms, odd and even harmonics were observed. The LC analysis indicated that there are 5 stages of insulator conditions from normal condition up to flashover correlated with different kind of LC waveforms. The results also showed that in general the magnitude of LC was good enough to show the condition of the insulators. However, under discharge condition (for example as a result of dry band arching) the LC magnitude should be combined by the THD to show a better correlation with the insulator condition. The product between THD and LC magnitude may be used as a diagnostic parameter.