• Title/Summary/Keyword: ozone

Search Result 2,319, Processing Time 0.037 seconds

A Study on Installation of Treatment Equipment of Malodorous Substances using the $O_3$ (오존($O_3$)을 이용한 악취물질 처리시설의 적용사례 연구)

  • 김석택
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.70-74
    • /
    • 2000
  • The technology of malodorous substances treatment was classified physical separation and chemical destruction. This study was carried out to investigate the characteristics of malodorous substances treatment with the change of operating conditions from the ozone generator. The major results of this study were as follows : Removal efficiency by additive ozone rate was measured $NH_3$:95%(ozone additive rate : 2), $H_2S$ : 97%(ozone additive rate:4), $CH_3SH$ : 96%(ozone additive rate : 3), $(CH_3)_2S_2$ : 97%(ozone additive rate:5), $(CH_3)_3N$ : 95%(ozone additive rate : 1), $CH_3CHO$ : 95%(ozone additive rate : 2), $C_6H_5CHCH_2$ : 95%(ozone additive rate : 2).

  • PDF

Measurement Technique of Ozone Density by Using UV Sensor System

  • Trung, Nguyen Huu;Van Men, Le;Van Hieu, Nguyen
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.80-86
    • /
    • 2015
  • There are many studies and products using a test paper impregnated with chemical solution can react with ozone. The color of a test paper can indicate the concentration of ozone. The purpose of this research is to design and manufacture a system using ultraviolet light source to measure the ozone density. This new technique is based on the characteristic of decomposition from ozone into oxygen under ultraviolet light. We used two sources of ultraviolet light including UV lamp and UVLED to determine the decomposition of ozone. This system is built with the electronic components, sensors and sealed pump tube to measure the ozone density in units of $g/cm^3$,ppm,ppb. In this paper,, we present some initial results of measuring the ozone density from ozone generator after completing inspection for safety.

Precipitation and Cloud Cover on High Ozone Days (고농도 오존일의 강우와 운량)

  • 김영성;김영진;윤순창
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.747-755
    • /
    • 1999
  • Effects of precipitation and cloud cover on high ozone days are examined by investigating the precipitation and average cloud cover before the ozone peak time within a day. High ozone days above 100 ppb in the Greater Seoul Area(GSA) for the ozone season from May to September are chosen for the analyses in terms of the surface meteorological data during 1990~1997. The result shows that the effect of precipitation on the rise of ozone concentration is definitely negative so that ozone concentration could not rise above 100ppb immediately after precipitation. But, the effect of cloud cover is associated with the variations of other meteorological parameters. The number of high ozone days with "zero" cloud cover is rather less than that with cloud cover of 1 to 4 since temperature is usually lower in "zero" cloud cover days. Furthermore, ozone concentration can rise above 100ppb even with full cloud cover when the wind is weak and the temperature is high.temperature is high.

  • PDF

High Efficiency Ozone Generation Using a Pyramid-Project-Embossed Rod-to-Cylinder Electrode and a Pulse Corona Discharge (도깨비봉형 오존발생장치이 펄스커로나 방전에 의한 오존 발생 특성)

  • 문재덕;이근택
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.8
    • /
    • pp.650-657
    • /
    • 1989
  • The conversion efficiency of an ozone generator can be significantly improved by modifying the discharge electrode of a helical strip line rod-to-cylinder type ozone generator to a pyramid-project-embossed rod, and by using a pulse corona discharge. Parametric studies have been carried out to obtain optimum values of peak pulse voltage, pulse forming capacitance, feeder cable and ozone generator capacitance, interelectrode spacing and corona tip density of ozone generator, and feed air flow rate and temperature. The generated ozone concentration was very dependent upon the value of pulse forming capacitance, feeder cable and ozone generator capacitance, and corona tip density. Maximum conversion efficiency was obtained with a pulse forming capacitance of about 500pF, 75pF matched feeder cable and ozone generator, and a corona tip density of 16mm. When operated at optimum values, ozone yield of 79, 99, 80 g/KWh for the different interelectrode type ozone generators tested were obtained, which are approximately 30% higher than that of an industrial ozone generator.

  • PDF

Stomatal Response by Ozone (오존에 대한 식물 기공 반응고찰)

  • 이준상;김병우
    • The Korean Journal of Ecology
    • /
    • v.20 no.2
    • /
    • pp.83-94
    • /
    • 1997
  • Stomatal closing by ozone and water stress could reduce further ozone injury by inhibition of ozone influx to the tissue. Direct effect of ozone on stomata can be explained from two aspects which are a stimulation of stomatal closing and an inhibition of stomatal opening. An increase of $Ca^{2+}$ influx into cytoplasm by ozone could stimulate potassium efflux ion channel and inhibits inward potassium ion channels. By this mechanism ozone could induce stomatal closing. On the other hand, ozone could inhibit stomatal opening by affecting the activity of $H^{+}$ dependent ATPase of the membrane in guard cells. This would inhibit proton efflux which precede stomatal opening. It is also possible that ozone could reduce the activity of photosynthesis in guard cells which lead to affect the production of osmotically active sugars and energy. Indirect effect of ozone to stomata is through the effect of $CO_2$ elevation as a result of damage of the photozynthetic machinery. This indirect effect is slower than the direct effect.

  • PDF

Construction and Evaluation of Oxidation System for Superconductor Thin Film (초전도 박막 제작을 위한 산화 시스템 구축 및 평가)

  • 임중관;박용필;송경용
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.2
    • /
    • pp.163-167
    • /
    • 2003
  • Ozone is strong and useful oxidizing gas for the fabrication of oxidation thin films. In order to obtain high quality thin film, the ozone concentration must be increased. An ozone condensation system is evaluated in the viewpoint of an ozone supplier for oxidation thin film growth. Ozone is condensed by the adsorption method and ozone concentration reaches 8.5 mol% by 2.5 h after the beginning of the ozone condensation is negligible if the condensed ozone is transferred between the ozone condensation system and the film growth chamber within a few minutes. CuO peak which is the result of the obtained Cu-films using condensed ozone appears by XRD patterns.

Comparison of Acetaminophen Degradation Performance using Advanced Oxidation Process (고급산화공정을 이용한 아세트아미노펜 분해 성능 비교)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.31 no.4
    • /
    • pp.319-328
    • /
    • 2022
  • This study investigated the treatment of acetaminophen in municipal wastewater by conventional ozonation, ozone-based advanced oxidation, ozone/UV, and the electro-peroxone process. The ozone/UV process and electro-peroxone process of electric power consumption increased 1.25 and 2.04 times, respectively, compared to the ozone process. The pseudo-steady OH radical concentration was the greatest in the electro-peroxone process and lowest in the ozone process. The specific energy consumption for TOC decomposition of the ozone/UV process and electro-peroxone process were 22.8% and 15.5% of the ozone process, respectively. Results suggest that it is advantageous in terms of degradation performance and energy consumption to use a combination of processes in municipal wastewater treatment, rather than an ozone process alone. In combination with the ozone process, the electrolysis process was found to be more advantageous than the UV process.

Indicative Responses of Rice Plant to Atmospheric Ozone

  • Hur, Jae-Seoun;Kim, Pan-Gi;Yun, Sung-Chul;Park, Eun-Woo
    • The Plant Pathology Journal
    • /
    • v.16 no.3
    • /
    • pp.130-136
    • /
    • 2000
  • Differences in physiological and biochemical responses between sensitive and tolerant rice cultivars to ozone were investigated to develop reliable indications of early ozone damage. Three Korean local rice cultivars -sen-sitive cultivar Dongjin (DJ), moderately tolerant cultivar Hwayeong (HY) and tolerant cultivar Ilmee (IM) were exposed to ozone at the concentrations of 100 nl $\textrm{l}^{-1}$ or 200 nl $\textrm{l}^{-1}$ , 8 h per day for 10 days in a controlled-environment fumigation chamber. The rice cultivars seemed to be endurable to ozone stress at the concentration of 100 nl $\textrm{l}^{-1}$ which is frequently monitored during the growing season in summer. However, severe damage was induced and differential sensitivity was clearly noted among the rice cultivars at the higher ozone concentration. Activation of the glutathion (GR) -ascorbate peroxidase (APX) cycle was likely to be responsible for protection of rice plants against ozone exposure, relating difference in sensitivity of rice cultivars to ozone. Photosynthetic activity appeared to be one of sensitive responses, for which chlorophyll fluorescence and leaf greenness can together provide a very reliable index, a degree of photosynthetic damages by ozone. Formation of malondialdehyde (MDA) was also considered as an indication that can differentiate cultivars sensitivity to ozone. However, the changes in polyamines and total phenolics were not consistent with exposed ozone concentrations and/or ozone sensitivity of the cultivars. The behavior of polyamines and phenolics in the damaged plants at high ozone levels could be interpreted as an indication of ozone injury rather than activation of additional protection mechanisms scavenging active oxygen species formed by ozone. Several responses triggered by ozone could explain the differential sensitivity of the rice cultivars and be used as reliable indications of relative ozone damage to rice plant.

  • PDF

Monitoring and Long-term Trend of Total Column Ozone from Dobson Spectrophotometer in Seoul (1985~2017) (돕슨 분광광도계를 이용한 서울 상공의 오존층 감시 및 장기변화 경향(1985~2017))

  • Park, Sang Seo;Cho, Hi Ku;Koo, Ja-Ho;Lim, Hyunkwang;Lee, Hana;Kim, Jhoon;Lee, Yun Gon
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.13-20
    • /
    • 2019
  • Since 1985, the Dobson Spectrophotometer has been operated at Yonsei University, and this instrument has monitored the daily representative total ozone in Seoul. Climatological value for total ozone in Seoul is updated by using the daily representative observation data from 1985 to 2017. After updating the daily representative total ozone data, seasonal and inter-annual variation of total ozone in Seoul is also estimated after calculating inter-comparison between ground (Dobson Spectrophotometer) and satellite [Total Ozone Mapping Spectrometer (TOMS) and Ozone Monitoring Instrument (OMI)] observations. The global average of total ozone measured by satellite is 297 DU, and its recent amount is about 3.5% lower than the global amount in 1980s. In Seoul, daily representative total ozone is ranged from 225 DU to 518 DU with longterm mean value of 324.3 DU. In addition, monthly mean total ozone is estimated from 290 DU (October) to 362 DU (March), and yearly average of total ozone have been continuously increased since 1985. For the long-term trend of total ozone in Seoul, this study is considered the seasonal variation, Solar Cycle, and Quasi-Biennial Oscillation. In addition to the natural oscillation effect, this study also considered to the long-term variation of sudden increase of total ozone due to the secondary ozone peak. By considering these natural effects, the long-term total ozone trends from 1985 to 2017 are estimated to be 1.11~1.46%/decade.

Intercomparison and evaluation of satellite-derived tropospheric ozone (인공위성을 이용한 대류권 오존 추정치 비교 및 검증)

  • Kim Jae-Hwan;Na Seon-Mi;M. J. Newchurch
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.123-124
    • /
    • 2003
  • Fishman and Larson (1987) derived tropical tropospheric column ozone by subtracting stratospheric column ozone measured by the Stratospheric Aerosol and Gas Experiment (SAGE) from total column ozone obtained by the Total Ozone Mapping Spectrometer (TOMS). Later, the Convective Cloud Differential (CCD) method (Ziemke et al., 1998) indicated stratospheric ozone is invariant with longitude and concluded the zonal variation of total ozone determines the zonal variation of tropospheric ozone. (omitted)