• Title/Summary/Keyword: ozone

Search Result 2,319, Processing Time 0.049 seconds

Analysis of Tropical Tropospheric Ozone Derivation from Residual-Type Method

  • Na Sun-Mi;Kim Jae-Hwan
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • During the northern burning season, biomass burning is found north of the equator, while satellite estimates from the residual-type method such as the CCD method show higher ozone south of the equator. This discrepancy is called the tropical Atlantic paradox (Thompson et ai., 2000). We use satellite and ground-based measurements to investigate the paradox. When the background tropospheric ozone over the Pacific Ocean from TOMS measurements is subtracted from the latitudinal total ozone distribution (e.g. TOMS-Pacific method), the results show remarkable agreement with the latitudinal stratospheric ozone distribution using the CCD method. The latitudinal tropospheric ozone distribution using the CCD method, with a persistent maximum over the southern tropical Atlantic, is also seen in the latitudinal tropospheric ozone distribution using the TOMS-Pacific method. It suggests that the complicated CCD method can be replaced by the simple TOMS-Pacific method. However, the tropical Atlantic paradox exists in the results of both the CCD and TOMS-Pacific methods during the northern buming season. In order to investigate this paradox, we compare the latitudinal ozone distributions using the CCD and TOMS-Pacific methods by using the SAGE measurements (e.g. TOMS-SAGE method) and the SHADOZ ozonesoundings (e.g. TOMS-Sonde method) assuming zonally invariant stratospheric ozone, which is the same assumption as of the CCD method. During the northern burning season, the latitudinal distributions in the tropospheric ozone derived from the TOMS-SAGE and TOMS-Sonde methods show higher tropospheric ozone over the northern tropical Atlantic than the southern Atlantic due to a stronger gradient in stratospheric ozone relative to that from the CCD and TOMS-Pacific methods. This indicates that the latitudinal tropospheric ozone distribution can be changed depending on the data that is used to determine the latitudinal stratospheric ozone distribution. Therefore, there is a possibility that the north-south gradient in stratospheric ozone over the Atlantic can be a solution of the paradox.

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

A Study on the Treatment of Organic Wastewater by Ozone Electrolysis (유기성 폐수의 오존전해처리에 관한 연구)

  • 정홍기;이태호
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.2
    • /
    • pp.59-63
    • /
    • 1996
  • To treat certain wastewater that has alcohol and phenol, we performed the ozone electrolysis by using the titanium electrode. In this experiment, we examined decomposition voltage of organics, time for electrolysis, and removal efficiency of organics. In addition we compared the ozone oxidation electrolysis. The followings are results; 1. When it comes to the alcohol treatment in wastewater, ozone electrolysis showed higher removal efficiency than ozone oxidation or electrolysis. 2. After comparing the decomposition rate of methylalcohol, ethylalcohol, and prophylalcohol in ozone electrolysis, we knew the fact that increasing carbon number made the decomposition rate slow. 3. According to the treatment of alcohol by ozone electrolysis, decomposition voltage was 50V, time for electrolysis was three hours, and treatment acidity was neutral (pH 6.5 - 8.1). 4. Ozone electrolysis was effective to the phenol treatment. When we treated phenol by using ozone electrolysis for three hours, TOC treatment efficiency was 95%. However, ozone oxidation just showed 45% treatment efficiency.

  • PDF

Comparison of tropospheric ozone derivation from TOMS and OMI

  • Kim, Jae-Hwan;Na, Sun-Mi
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.308-311
    • /
    • 2006
  • This study compared between tropospheric column ozone by applying the SAM method to TOMS and OMI data for northern summer. Tropospheric ozone from the SAM represents a peak over the tropical Atlantic, where it is related with biomass burning. This feature is also seen in the distribution of the model and CO. Additionally, enhancement of the SAM ozone over the Middle East, and South and North America agrees well with the model and CO distribution. However, the SAM results show more ozone than the model results over the northern hemisphere, especially the ocean (e.g. the North Pacific and the North Atlantic). The tropospheric ozone distribution from OMI data shows more ozone than that from TOMS data. This can be caused by different viewing angle, sampling frequency, and a-priori ozone profiles between OMI and TOMS. The correlation between the SAM tropospheric ozone and CO is better than that between the model and CO in the tropics. However, that correlation is reversed in the midlatitude.

  • PDF

Shelf-Life of Soybean Curd Prepared with Ozone-treated Soybeans (콩의 오존처리가 두부의 저장성에 미치는 영향)

  • 김일두;박미자
    • Food Science and Preservation
    • /
    • v.5 no.1
    • /
    • pp.73-80
    • /
    • 1998
  • Shelf-life of soybean curd prepared with ozone-treated soybeans investigated on pH, acidity, sour taste, slime formation during storage at 3$0^{\circ}C$. Total Plate counts of raw soybeans showed about log 7.0 CFU/g before ozone treatment. The sterilization efficiency of raw soybeans showed the most effective in 0.5ppm of aqueous ozone treatment at 4$^{\circ}C$ for 90 minutes. Raw soybeans were treated with ozone by different methods; (1) Ozone treatment for 90 + 90 minutes (first 3.5~5 hours and later 8.5~10 hours) of 10 hours during soaking in aqueous solutions at 4$^{\circ}C$ (OW). (2) Ozone treatment by exposure first to 30ppm of gaseous ozone for 90 minutes and then allied to OW method (GO+OW). The log reduction of raw soybeans treated by OW and GO+OW methods showed 3.72 and 4.15, respectively. Soybean curd prepared with OW and GO+OW-treated soybeans kept the shelf-life of 4 and 5.5 days at 3$0^{\circ}C$, respectively, but, that without ozone treatment spoiled at me day.

  • PDF

Construction and Evaluation of $O_3$ Condensation System for Oxide Thin Film (산화 박막 성장을 위한 $O_3$ 농축 시스템의 구축 및 평가)

  • Lim, Jung-Kwan;Ryu, Sun-Jong;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1192-1195
    • /
    • 2003
  • A highly condensed ozone gas be transferred to the superconductor thin film growth chamber because ozone is strong oxidizing gas. In order to obtain high quality oxide thin films, higher ozone concentration is necessary. In this paper an ozone condensation system was evaluated from the viewpoint of an ozone supplier for oxide thin film growth. Ozone was condensed by an adsorption method and the ozone concentration reached 8.5 mol% in 2.5 h after the beginning of the ozone condensation process, indicating high effectiveness of the condensation process. Ozone was continuously desorbed from the silica gel by the negative pressure.

  • PDF

A Comparative Study of Catalytic Ozone processes for Removal of Refractory Organics (난분해성 유기물질 제거를 위한 오존/촉매 공정의 비교에 관한 연구)

  • Lee, Gyu-Hwan;Lee, Yu-Mi;Rhee, Dong-Seok
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.199-205
    • /
    • 2006
  • Ozone alone and catalytic ozone processes were introduced for treatment of humic acid, which is representative refractory organic compound. The treatment efficiencies of humic acid in each process were analyzed in pH variation, DOC removal, and $UV_{254}$ decrease. Mn loaded GAC catalyst was prepared by loading potassium permanganate onto the granular activated carbon surface. BCM-GAC and BCM-Silica gel catalyst were prepared by BCM. $UV_{254}$ decrease in all processes was comparatively high with efficiency over 87%. DOC removal in ozone/GAC process was the highest with 78%, and removal rates for other processes followed the order ozone/BCM-GAC(62%) > ozone/BCM-silica gel(45%) > ozone/silica gel(43%) > ozone/Mn Loaded GAC(42%) > ozone alone(37%).

  • PDF

Studies of High-Ozone Episodes in the Greater Seoul Area between 1990 and 1997 (1990~1997 기간 중 서울.수도권 지역의 고농도 오존 사례 연구)

  • 김영성;오현선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.3
    • /
    • pp.267-280
    • /
    • 1999
  • To investigate the characteristics of high-ozone occurrences in the Greater Seoul Area(GSA), three high-ozone episodes were selected, for which the ozone warning for concentration above 120 ppb might be issued. The selection was on the basis of morning wind directions and speeds, and daily maximum ozone concentrations measured between 1990 and 1997. The episodes chosen to meet selection criteria were seven days in July 1992, nine days in July 1994, and three days in August 1994, as respectively characterized by southwesterly, easterly, and calm winds in the morning. However, more than 80% of high-ozone days in the GSA were associated with calm winds and the concomitant accumulation of local emission in the morning, rather than being due to transport of ozone or its precursors. This is believed to be the primary reason why ozone concentrations in the GSA varied in a completely different manner even between adjacent monitoring stations. Several premises for initiating research studies for resolving these local variations of ozone concentrations in the GSA are also discussed.

  • PDF

Trial Manufacture of Ozone Generator Using Silent Discharge Type and Improvement Properties of the Water Quality in the Lake (무성방전형 오존발생장치 제작 및 수질 개선 특성)

  • 임헌찬;김진규;우성훈
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.125-129
    • /
    • 2001
  • ln this paper, a ozone generator using superimposition of silent discharge has been designed and manufactured. This type ozone generator is equipped with three electrodes and two gaps. Ozone is generated by superimposition of silent discharge, which is respectively come from two gaps. The maximum values of ozone concentration, ozone generation flow and ozone energy field were obtained 4,750[ppm], 2.37[g/h], 102.3[g/kWh]. Also, the result of reaction of 1,8921ppm] ozone and the sampling water from the lake, the water quality was improved from IV grade to In grade, and obtained 100[%] sterilization rate of Escherichia coli within 5.0(min).

  • PDF

Characteristics of Residual Ozone Decomposition with Commercial Ozone Decomposition Catalyst (ODC) and Photo catalyst (상업용 오존촉매와 광촉매를 이용한 오존제거특성)

  • Byeon, Jeong-Hoon;Park, Jae-Hong;Hwang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1255-1260
    • /
    • 2004
  • Decomposition of ozone at room temperature was investigated comparatively with commercial monolithic ozone decomposition catalyst (ODC, $MnO_2$) and monolithic photo catalyst ($TiO_2$). The effects of residence time, UV (ultraviolet) light dependence and ozone concentration on the conversion was presented. UV ray was irradiated using BLB (black light blue) lamp ($315{\sim}400$ nm), supplied with a constant intensity in the reactor. The concentration of ozone in the square-shape reactor can be controlled by combining the DBD (dielectric barrier discharge) reactor with an AC high voltage supply system. The catalytic performance, in presence of UV irradiation did not show significant changes for $MnO_2$ catalyst. $TiO_2$ catalyst was the different case, which showed higher decomposition activity in presence of UV irradiation. Deactivation of catalyst detected by real-time ozone monitor for 120 hours with a constant inlet ozone concentration.

  • PDF