• 제목/요약/키워드: pH test

검색결과 4,112건 처리시간 0.029초

B형 간염백신 'Hepa-Vax' 접종후 항체검사시약 'Hepa-S' kit의 정확도에 관한 연구 (A Study on the Validity of 'Hepa-S' Hepatitis B Antibody Detecting Reagent after Vaccination of 'Hepa-Vax')

  • 문인숙
    • Journal of Preventive Medicine and Public Health
    • /
    • 제18권1호
    • /
    • pp.51-57
    • /
    • 1985
  • To attempt to measure the effect of domestic product P.H.A. kit 'Hepa-S' after completion of 'Hepa-Vax' vaccination schedule, P.H.A. test and R.I.A. test on the 330 healthy adults were carried out. The results obtained were as follow ; 1. The positive anti HBs rate after completion of 'Hepa-Vax' vaccination were; in P.H.A. test with domestic product P.H.A. kit 81.2%, in P.H.A. test with foreign product P.H.A. kit 82.7%, and in R.I.A. test 95.8% 2. Using the result of R.I.A. test as the standard, sensitivity of P.H.A. test with domestic product P.H.A. kit was 84.8% and specificity was 100.0% 3. Using the result of R.I.A. test as standard, sensitivity of P.H.A. test with foreign P.H.A. kit was 86.4% and specificity was 100.0%. 4. The concordance rate of P.H.A. test with domestic product and foreign product kit was 98.5%. On the result of this study, there was no significant difference in the validity between the domestic product P.H.A. kit 'Hepa-S' and the foreign P.H.A. kit $'Hebsgencell^{TM}'$. So that it is recommendable to use domestic product P.H.A. kit instead of foreign product P.H.A. kit.

  • PDF

측정방법 및 시간경과에 따른 순환골재의 pH 특성에 관한 연구 (A Study on the pH Characteristic of Recycle Aggregate According to Test Methods and Elapsed Time)

  • 송태협;이종찬;이세현
    • 한국건설순환자원학회논문집
    • /
    • 제6권3호
    • /
    • pp.61-68
    • /
    • 2011
  • 시멘트의 강알칼리성 성분으로 인하여 파분쇄된 순환골재의 pH는 12이상을 발현한다. 이 시멘트의 강알카리성은 환경적으로 피해를 주게 된다. 순환골재의 강알카리성은 골재의 특성, 알카리 용출시간, 골재의 크기 등에 따라 다양하게 나타날 수 있다. 본 연구에서는 이러한 다양한 조건에 따른 순환골재의 pH 특성을 시험하기 위하여 습식 및 건식 생산공정에서 생산한 건식 및 습식 순환골재를 이용하여 폐기물공정 시험방법, 토양오염공정 시험방법, BS EN 1744-3에서 제시한 pH 시험방법에 따른 pH 특성, 순환골재의 용출시간에 따른 pH의 특성, 골재의 입도별 pH 특성을 분석하여 순환골재의 환경적 문제를 해결하는데 기여하고자 하였다. 시험결과에서는 순환골재는 입도가 작을수록 pH가 높은 것으로 나타났으며, 시간 경과에 따라 증가하는 것으로 나타났다. 건식과 습식 순환골재의 pH 경향은 시간 경과에 따른 차이 외에 시험방법에 의한 차이는 없었다. pH 시험방법에 있어서 폐기물공정시험에 의한 순환골재 pH값이 가장 높게 나타나 pH 편차를 고려한 단일 pH 시험방법 제안이 요구된다.

  • PDF

시판주류의 pH 측정 연구 (A pH Measurement Study on Commercial Alcoholic Drinks)

  • 심재순;송애희
    • 치위생과학회지
    • /
    • 제12권6호
    • /
    • pp.696-701
    • /
    • 2012
  • The purpose of this study was to determine pH value of some alcoholic drinks sold in Korea and to provide the basic information which can cause dental erosion. Alcoholic drinks commercially sold were purchased from various big markets in Korea. The sorts of drinks tested in this study consisted of 5 brands of beers, 24 brands of makgeollis, 9 brands of wines and 12 brands of sojus. The test groups were selected randomly and the pH of each beverage was determined using a pH meter he each pH was measured. For statistical data, Mann-Whitney test was used to analyze difference for red wine and white wine and Kruskal-Wallis test was used to compare the pH of each test group. The result of this study was as followings: the mean pH of 5 brands of beers was 4.21, that of 24 brands of makgeollis 3.88, of 9 brands of wines 3.34 and of 12 brans of sojus 7.86. Each test group was significantly different (p<0.05). Except for soju groups, the test groups had a low pH value which can cause dental erosion. In terms of comparing between pH value of red wine and white wine, the result of this study represented that the mean pH of red wine was 3.45 and that of white wine was 3.21. This result showed the pH of two kinds of wine had a low pH which can lead to dental erosion and the difference of two wine were significantly different (p<0.05). As a result, some drinks sold in Korea have a high erosive potential on teeth since they have a comparatively low pH expect soju. Hence, when we consume some kinds of alcoholic drinks, we make sure to remember that the alcoholics which had a low pH, can have an effect on dental erosion that mean we should avoid to drink some alcoholic drinks with low pH for long time.

인공해수의 pH에 따른 강 용접부의 응력 부식균열거동에 관한 연구 (A Study on the Stress Corrosion Cracking Behaviors for Weld Joint of Steel with Various pH Values in Synthetic Sea Water)

  • 유효선;나의균;정세희
    • Journal of Welding and Joining
    • /
    • 제13권1호
    • /
    • pp.78-88
    • /
    • 1995
  • This paper was performed to study the utility of the SP(small punch) test and the AE(acoustic emission) test in the evaluation of SCC(stress corrosion cracking) susceptibility for parent metal and bond line of HT80 steel-weld joint by SAW(submerged arc welding) with the various pH values. The loading rate used was 3*10$^{-4}$ mm/min and the corrosive environment used was synthetic sea water during the SP test and the AE test. According to the test results, the SCC susceptibility of the parent metal was increased in the order of pH6.0, pH8.2 and pH10.0. On the other hand, the bond line showed almost the same high SCC susceptibility in all pH concentrations. Synthetically, from the results of the SCC susceptibility, the macro- and micro-SEM observation, the microfracture behaviors by AE test and the relationship between SCC susceptibility and displacement at incipient failure, .delta.$_{i.f-AE}$, it can be concluded that the SP test and the AE test are the good test methods to evaluate the SCC susceptibility for parent metal and bond line of the weld joint with the change of environmental factors.

  • PDF

pH 측정의 숙련도 시험에 대한 연구 (A Study on the proficiency test of pH measurements)

  • 이화심;김명수;최종오
    • 분석과학
    • /
    • 제14권3호
    • /
    • pp.230-237
    • /
    • 2001
  • 일반적인 pH의 측정은 유리전극을 사용한 pH 측정기를 pH 표준용액으로 검정한 다음, 시료용액의 pH를 측정하는 절차를 따른다. 일정 온도의 pH 측정에서 불확도에 영향을 미치는 인자는 pH 표준용액의 불확도와 유리전극의 정확도 및 재현성이라 할 수 있다. 본 연구에서는 실제로 동일한 시료에 대해 각 실험실에서 측정하고 있는 pH 측정값이 어떠한 분포를 보이며, 오차 발생 시 주된 요인이 무엇인지를 알기 위해 pH 표준용액 시료를 사용하여 자원하는 국내의 실험실을 대상으로 98, 99년에 걸쳐 숙련도 시험을 실시하였다. 숙련도 시험 시료는 $25^{\circ}C$에서 pH 6.860, 7.415의 값을 가지는 인산염 표준용액을 제조하여 사용하였고, 숙련도 시험 기간내의 안정도 여부를 확인하기 위해 안정도 시험을 실시하였다. 숙련도 시험 결과를 Youden plot하여 측정 결과의 오차가 우연효과에 의한 것인지 계통효과에 의한 것인지를 파악하였을 때, 두 해 모두 오차를 갖는 실험실들이 계통효과에 의한 오차만을 나타내었다. 이는 각 실험실에서 사용하고 있는 표준용액이 오차의 원인임을 말해 주고 있다.

  • PDF

일반(一般) 정기(定期) 건강진단자(健康診斷者)의 T.P.H.A양성율(陽性率) (T.P.H.A Positive Rate of General and Ordinary Health Examine)

  • 이화숙;이수영;김강석
    • 보험의학회지
    • /
    • 제2권1호
    • /
    • pp.253-259
    • /
    • 1985
  • In medical selection of Daehan Education Insurance, for 6 months from June 1st, 1984 to November 30th, 1984 we examined 2523 persons, who were supposed to receive general test and Normal subject test Then we did syphilis test by selecting the way of R.P.R. card test and repeatedly confirming the examination serologically. The results are as follows: 1) As results of R.P.R. card test, 30 out of 1592 males are positive(1.89%) and 10 out of 931 females are positive(1.1%). 40 out of total 2523 persons are positive(1.6%). 2) As results of T.P.H.A, 28 out of 1592 males are positive(1.76%) and 9 out of 931 females are positive. 37 out of total 2523 persons are positive(1.47%). 3) When R.P.R. card test is compared with T.P.H.A test, 40 persons by R.P.R. showed that 2 males and female are negative and only 37 persons are positive in T.P.H.A test. And so the result agreement rate of R.P.R. card test and T.P.H.A test showed 92.5%. 4) In the age-distribution males have high positive rates in 30's and 40's and females have high positive rates in 20's and 40's when the subjects are normal.

  • PDF

Effect of $H_2S$ Partial Pressure and pH of Test Solution on Hydrogen Induced Cracking of High Strength Low Alloy Steels

  • Kim, Wan Keun;Koh, Seong Ung;Kim, Kyoo Young;Yang, Boo Young;Jung, Hwan Kyo
    • Corrosion Science and Technology
    • /
    • 제4권6호
    • /
    • pp.236-241
    • /
    • 2005
  • Hydrogen induced cracking (HIC) is one of the hydrogen degradation phenomena of linepipe steels caused by $H_2S$ gas in the crude oil or natural gas. However, NACE TM0284-96 standard HIC test method is hard to satisfy the steel requirements for sour service application since it uses more severe environmental conditions than actual conditions. Therefore, in order to use steels effectively, it is required to evaluate HIC resistance of steels in the practical range of environmental severity. In this study, HIC resistance of two high strength low alloy (HSLA) steels being used as line pipe steels was evaluated in various test solutions with different $H_2S$ pressures and pH values. The results showed that the key parameter affecting crack area ratio (CAR) is $H_2S$ partial pressure of test solution when the pH value of test solution is not over 4. Hydrogen diffusivity was not a constant value, but it was rather affected by the hydrogen ion concentration (pH value) in the solution.

플라이 애쉬를 다량 치환한 콘크리트의 중성화 특성에 관한 실험적 연구 (The Experimental Study on Neutralization Properties of High Volume Fly-Ash Concrete)

  • 백민수;김우상;김종원;김제섭;김성식;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.69-74
    • /
    • 2003
  • This study evaluated durability through measurement of substituted test piece's pH degree and experiments of neutralization. Comparing and evaluating cared test piece's pH degrees which we got before the neutralization and after the neutralization. After evaluating neutralization depth through neutralization, evaluating neutralization properties by Fly Ash replacement ratio. pH degree was decreased by cement replacement ratio of Fly Ash. And in the case of substitution of the same amount of Fly Ash, fine aggregate replacement ratio was increased. When the test piece, which had been cared in high temperature, was promoted to neutralization, Among the test piece which was replaced with Fly Ash 40%, the test piece which has high rate of fine aggregate proved opposition of neutralization Through the test, Ⅰ summarized that the test piece cared in high temperature was mostly effected by compress strength, the test piece cared in low temperature was mostly effected by pH degree.

  • PDF

Repassivation Behavior of Ni Base Alloys in a Mild Alkaline Water at 300℃

  • Hwang, Seong Sik;Kim, Dong Jin;Kim, Joung Soo;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • 제5권3호
    • /
    • pp.85-89
    • /
    • 2006
  • KAERI(Korea Atomic Energy Research Institute) has developed a repassivation rate test system which can be operated at $300^{\circ}C$. It consists of an autoclave, three electrodes for an electrochemical test and a diamond scratch tip. All the electrodes are electrically insulated from the autoclave by using high temperature fittings. Reproducible repassivation curves of alloy 600 at 300 C were obtained. Repassivation rate of alloy 600 at pH 13 was slower than that of pH 10. Stress corrosion cracking test was carried as a function of the pH at a high temperature. At pH 10, alloy 600 showed a severe stress corrosion cracking(SCC), whereas it did not show a SCC at pH 7. From the viewpoint of a relationship between the current density and the charge density, a big difference was observed in the two solutions; the slope of pH 13 was steeper than that of pH 10. So the stress corrosion susceptibility at pH 13 seems to be higher than that of pH 10. The system would be a good tool to evaluate the SCC susceptibility of alloy 600 at a high temperature.

매립지 환경조건을 고려한 소각재와 도금슬러지의 중금속 용출특성 (Leaching Characteristics of Heavy Metals of Bottom Ash and Plating Sludge with Environmental Conditions in Landfill)

  • 손희정;김은호;이용희
    • 환경위생공학
    • /
    • 제13권2호
    • /
    • pp.121-127
    • /
    • 1998
  • This study was to understand leaching characteristics with pH controlling agents and Temp. control, and investigate leaching characteristics with pH control from opening a leaching test to an end for reassessing leaching test of heavy metals with environmental conditions in landfill. Because leaching of heavy metals was increased in low pH, pH must control for leaching in existing leaching test. Generally, regulation time(6hr) of leaching was confirmed reasonablely, except for Cu in plating sludge. In pH controlling solution, there was nearly not difference between Acetic acid and HCl and if considering Cu, the former was appropriate. In a part of heavy metal, leaching rate was increased in high Temp., and normal Temp. in existing leaching test would be revaluated.

  • PDF