• Title/Summary/Keyword: parameter calibration

Search Result 410, Processing Time 0.193 seconds

Sensitivity Analysis and Parameter Estimation of Activated Sludge Model Using Weighted Effluent Quality Index (가중유출수질지표를 이용한 활성오니공정모델의 민감도 분석과 매개변수 보정)

  • Lee, Won-Young;Kim, Min-Han;Kim, Young-Whang;Lee, In-Beum;Yoo, Chang-Kyoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.11
    • /
    • pp.1174-1179
    • /
    • 2008
  • Many modeling and calibration methods have been developed to analyze and design the biological wastewater treatment process. For the systematic use of activated sludge model (ASM) in a real treatment process, a most important step in this usage is a calibration which can find a key parameter set of ASM, which depends on the microorganism communities and the process conditions of the plants. In this paper, a standardized calibration protocol of the ASM model is developed. First, a weighted effluent quality index(WEQI) is suggested far a calibration protocol. Second, the most sensitive parameter set is determined by a sensitive analysis based on WEQI and then a parameter optimization method are used for a systematic calibration of key parameters. The proposed method is applied to a calibration problems of the single carbon removal process. The results of the sensitivity analysis and parameter estimation based on a WEQI shows a quite reasonable parameter set and precisely estimated parameters, which can improve the quality and the efficiency of the modeling and the prediction of ASM model. Moreover, it can be used for a calibration scheme of other biological processes, such as sequence batch reactor, anaerobic digestion process with a dedicated methodology.

Study on the Observability of a Calibration System for a Parallel Tilting Table with Measuerment Operator (측정연산자에 의한 병렬기구 틸팅 테이블의 관측성에 관한 연구)

  • Park Kun Woo;Lee Min Ki;Kim Tae Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.6 s.237
    • /
    • pp.795-803
    • /
    • 2005
  • This paper studies the observability of calibration system with a measurement operator. The calibration system needs a simple digital indicator to measure the mobile table movements with respect to the MC coordinate. However, it yields the concern about the poor parameter observability due to measuring only a part of the movements. We uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of an observation matrix. The number of identifiable parameter is examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a 6-axis MC with parallel tilting table and the calibration results are presented. These results verify that all necessary kinematic parameters are observable and the calibration system has robustness to the noise using optimal calibration configurations.

Development of TCAD calibration methodology for ESD simulation and TLP measurement analysis (ESD 시뮬레이션과 TLP 측정해석을 위한 TCAD calibration methodology 개발)

  • 염기수
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.538-542
    • /
    • 1999
  • New methodology of parameter calibration is proposed for TCAD simulation of nMOSFET in ESD(Electro-Static Discharge) protection circuits. Recently, TLP(Transmission Line Pulsing) measurement has received great interest due to the ability of analyzing device characteristics when ESD pulse is applied to the ESD pulse is applied to the ESD protection circuits. This paper describes new methodology of analyizing TLP measurement, TCAD simulation, and parameter calibration.

  • PDF

Estimation of Camera Calibration Parameters using Line Corresponding Method (선 대응 기법을 이용한 카메라 교정파라미터 추정)

  • 최성구;고현민;노도환
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.10
    • /
    • pp.569-574
    • /
    • 2003
  • Computer vision system is broadly adapted like as autonomous vehicle system, product line inspection, etc., because it has merits which can deal with environment flexibly. However, for applying it for that industry, it has to clear the problem that recognize position parameter of itself. So that computer vision system stands in need of camera calibration to solve that. Camera calibration consists of the intrinsic parameter which describe electrical and optical characteristics and the extrinsic parameter which express the pose and the position of camera. And these parameters have to be reorganized as the environment changes. In traditional methods, however, camera calibration was achieved at off-line condition so that estimation of parameters is in need again. In this paper, we propose a method to the calibration of camera using line correspondence in image sequence varied environment. This method complements the corresponding errors of the point corresponding method statistically by the extraction of line. The line corresponding method is strong by varying environment. Experimental results show that the error of parameter estimated is within 1% and those is effective.

Study on Optimal Calibration Configurations of a Parallel Type Machining Center Under a Single Planar Constraint

  • Lee, Min-Ki;Kim, Tae-Sung;Park, Kun-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.1886-1893
    • /
    • 2003
  • This paper examines the parameter observability of a calibration system that consrains a mobile platform to a planar table to take the calibration data. To improve the parameter observability, we find the optimal configurations providing the calibration with maximum contribution. The QR-decomposition is used to compute the optimal configurations that maximize the linear independence of rows of an observation matrix. The calibration system is applied to the parallel type manipulator constructed for a machining center. The calibration results show that all the necessary kinematic parameters assigned in a Stewart-Gough platform are identifiable and convergent to desirable accuracy.

Study on the Observability of Calibration System with a Constraint Oprerator (구속연산자에 의한 보정 시스템의 관측성에 관한 연구)

  • Lee, Min-Ki;Kim, Tae-Sung;Park, Kun-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.647-655
    • /
    • 2003
  • This paper studies the observability of calibration system with a constraint movement by a constraint operator. The calibration system with the constraint movement need only simple sensing device to check whether the constraint movements are completed within an established range. However, it yields the concern about the poor parameter observability due to the constraint movements. This paper uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of a observation matrix. The number of identifiable parameters are examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a parallel typed machining center and the calibration results are presented. These results verify that the calibration system with low-cost indicators and simple planar table is accurate as well as reliable.

Errors in Recorded Information and Calibration of a Catchment Modelling System(II) - Monitoring Calibration Approach - (기록치 오차와 유역모형의 검정(II) - 모니터링 검정방법 -)

  • Choi, Kyung Sook
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.117-125
    • /
    • 2003
  • Since the recorded information used for operation of a catchment modelling system contain errors that influence the calibration of catchment modelling system control parameter values, the accurate estimation of these parameters is difficult. Despite these influences, existing traditional calibration approaches focus only on achieving the best "curve fitting" between simulated and recorded data, and not on generic evaluation of control parameter values. This paper introduces an Early Stopping Technique which is aimed at avoiding the procedure of curve-fitting through monitoring improvements in the objective function used for assessing the optimal parameter set. Application of this approach to the calibration of SWMM (Storm Water Management Model) on the Centennial Park catchment in Sydney, Australia is outlined. outlined.

Study on Calibration for Parallel-Typed Tilting Table (병렬기구형 틸팅 테이블의 보정에 관한 연구)

  • Kim, T.S.;Jung, J.W.;Kim, Y.H.;Park, K.W.;Lee, M.K.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1512-1517
    • /
    • 2003
  • This paper presents the calibration for the parallel typed tilting table. The calibration system needs only simple sensing device which is a digital indicator to measure the orientation of a table. The calibration algorithm is developed by a measurement operator. It eliminates the concern about the poor parameter observability due to a large number of parameters of parallel-mechanism. This paper uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of a observation matrix. The number of identifiable parameters is examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a Parallel-typed Tilting Table and all the necessary kinematic parameters are identifiable.

  • PDF

The Study of Circuit Model Parameter Generation Using Device Simulation (소자 시뮬레이션을 이용한 Circuit Model Parameter 생성에 대한 연구)

  • 이흥주
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.177-182
    • /
    • 2003
  • In the case of the flash memory, various kinds of transistors and the wide range of operation voltage are necessary to achieve the read/write operations. Therefore, the characteristics of transistors are measured in the silicon for the circuit design, and the test vehicle run must be processed. In this study, an efficient design flow is suggested using TCAD tools. The test vehicle is replaced with well-calibrated TCAD simulation. First, the calibration methodology is introduced and tested for flash memory device. The calibration errors are less than 5% of a full chip operation, which is accepted by the designers. The results of the calibration were used to predict I-V curves and model parameter of the various transistors for the design of flash device.

  • PDF

Study on Kinematic Calibration of a Parallel-typed Machining Center Tool (병렬기구형 공작기졔의 기구학적 보정에 관한 연구)

  • Lee, Min-Ki;Kim, Tae-Sung;Park, Kun-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2237-2244
    • /
    • 2002
  • This research develops a low-cost and high accuracy kinematic calibration method based on the following principles: 1) the platform locations are accurately measured by a constrained movement to inspect a calibration target; 2) the constrained movement is chosen to guarantee the parameter observability; 3) the mechanical fixture to constrain the movement and the sensor to check the constrained movement are implemented by low-cost and high-accuracy devices; 4) the calibration is easily done at an industrial environment. The kinematic parameters calibrated with respect to a single plane aren't influenced due to the misalignment of the plane. A parameter observability is successfully obtained even through one planar constraint, which guarantees that all kinematic parameters are estimated by minimizing the cost function.