• Title/Summary/Keyword: partial disconnection

Search Result 18, Processing Time 0.029 seconds

Study on the Risk Analysis of Complex Electrical Fire by the Partial Disconnection and Tracking (반단선과 트래킹에 의한 복합적 전기화재의 위험성분석 연구)

  • Park, Sang-Min;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.111-118
    • /
    • 2017
  • The present paper is a study on the risk analysis of complex electrical fire by the partial disconnection and tracking. First, in order to analysis the single cause of electrical fire risk by the partial disconnection, the thermal characteristic has been measured by the change in the number of strands and the rated current of a wire. And then, in order to analysis the electrical fire risk by complex cause, an experiment on the accelerated tracking has been carried out in a condition of partial disconnection and confirmed the fire relation between partial disconnection and tracking. From the experiment, if the partial wire disconnection acts as a single cause, the existing thermal characteristics generated by the flowing current has appeared more clearly by the increase in the flowing current due to the complex action of tracking. Accordingly, the disconnection of strands has appeared by the complex cause due to the drastic temperature increase which was not generated in the single cause. Namely, it has been confirmed that if the partial disconnection and tracking act complexly rather than the risk of electrical fire by the existing partial disconnection, relatively its risk has been increased in large.

Analysis of Thermal Characteristics for the Fire Risk Assessment According to Partial Disconnection on the VCTF and IV Electric Wire (VCTF와 IV전선의 반단선에 의한 화재위험성 평가를 위한 열적특성 해석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Park, Jong-Young;Park, Young-Ho;Lee, Hyung-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.47-52
    • /
    • 2008
  • Many researches on fire risk for normal electric wiring have been pursued in advanced countries such as the USA and Japan, but comparative studies of the partial disconnection and normal state of electric wires have not been conducted. Detection system for the cause of partial disconnection is not developed and prevention countermeasure for electrical fire by the cause is not effective. Therefore, in this paper, partial disconnection characteristics on electric wires were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF(PVC insulated PVC sheathed Cap Tyre Flexible Cord, KS C 3304) and IV(lndoorwire PVC, KS C 3302). VCTF is used in wiring portable electric appliances and the IV is used indoors. Interrelationships between partial disconnection premonitory symptom and current were derived and analyzed by the characteristics based on experiments and thermal analysis for electric wire according to current under normal state and 200% overload state of rated current.

Development of Thermal Precursor DB for Partial Disconnection and Poor Contact on Electrical Wire (배선에서의 반단선 및 접촉불량에 대한 열적 전조 DB구축)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Kang, Dong-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.30-36
    • /
    • 2009
  • This paper aims at the precursor analysis and DB development of electrical fires based on thermal and current signals for partial disconnection and poor contact on electric wires through experiments and simulations. Also, DB system required for developing the precursor DB with these data was studied and designed. Firstly, in case of partial disconnection, characteristics were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF and IV electric wires. Based on the characteristics, About 351 partial disconnection precursor patterns were generated by the thermal analysis for electric wire according to deterioration time under normal state and 200% overload state of rated current. Secondly, in order to develop poor contact precursor patterns, temperature value and the current signal were considered. In simulating the poor contact situation on connector area of MCCB, connection torque was changed. Through the experimental analysis, about 251 poor contact precursor patterns were generated. Finally, Using thermal precursor patterns obtained by partial disconnection and poor contact, electrical fire thermal precursor DB was developed.

Design and Prototyping of Partial Connection Manager for Mobile Computing Service (이동 컴퓨팅 서비스를 위한 부분 연결 관리자의 설계 및 프로토타입핑)

  • Kim, Pyeong-Jung;Yun, Seok-Hwan;Jin, Seong-Il
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.6
    • /
    • pp.1932-1940
    • /
    • 2000
  • We must solve problems caused by mobile computing environments for supporting efficient mobile computing services. The problem is the use of wireless medium having high error rates and low bandwidth, and the sudden network disconnection to reduce the power consumption of a mobile host and the cost of the network connection. For these problems, we proposed the architecture of the partial connection manager and designed and implemented that in this paper. In particular, The partial connection manager creates the limited number of mobile agents according to priority and sends them in parallel to server systems and combines results of them process rapidly the user request. By applying the proposed partial connection manager to the mobile computing services called cybermarket, we knew that the mobile agent technique could be suited to the mobile computing environment and overcome the partial connection problem caused by eh mobile computing environment.

  • PDF

Fault Diagnosis Device for Fire Prevention of the Resistance Heating Type three-Phase Electric Heater (3상 저항가열식 전기히터의 화재예방을 위한 결함 진단장치)

  • Lee, Mun-Hyung;Kim, Chan-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1669-1674
    • /
    • 2017
  • In this study, We have discussed the development of a diagnostic device to detect and prevent electrical fire due to the arc caused by contact failure and partial disconnection at the connection part of the three-phase electric heater wiring used in the industrial field. The arc caused by contact failure and partial disconnection at the connection part of the electric heater shows a change in the current effective value. Therefore, it is possible to determine whether there exists a defect by analyzing the current unbalance factor and the number of current fluctuations with the diagnostic apparatus. The three-phase unbalanced heater is considered to be capable of determining defects through periodic measurement and trend analysis of the current unbalance factor. It is also expected that this device can be used not only for electric heaters but also for detection of defects in wiring and connections of electrical equipment having a characteristic of constant load current.

A Study on Efficient Energy Saving Protocol in Ubiquitous Sensor Network (유비쿼터스 센서 네트워크 환경 하에서 효율적인 에너지 절약형 프로토콜에 관한 연구)

  • OH, Gi Oug;Park, Mi Ok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.10
    • /
    • pp.121-128
    • /
    • 2013
  • Existing sensor network studies have only emphasized energy aspects that sensors themselves had. But when an actual sensor network is established, biased use of a specific sensor may cause a partial disconnection of the sensor network. It becomes an disadvantage to fail efficient operation of the sensor network for a long time and energy efficiency of specific sensor energy causes to drop the efficiency of the sensor network. When a sensor network is composed of many clusters or made up of a large network, sensor network's disconnection cannot be avoided because they emphasize sensor's energy efficiency. Therefore, it was tried to lengthen the lifespan of the sensor network by making sensors in the sensor network avoid disconnection through even use of all the sensors composing of the sensor network. This article proposes a protocol to maintain a sensor network for a long time by preventing a sensor networks' disconnection through efficient management of sensor network energy composed of the protocols composing of the sensor network in ubiquitous environments.

Adaptive Cache Maintenance Scheme based on Connection States in Mobile Computing Environments (이동 컴퓨팅 환경하의 연결 상태를 기반으로 한 적응적 캐쉬 유지 기법)

  • Nam, Sung-Hun;Cho, Sung-Ho;Hwang, Chong-Sun
    • Journal of KIISE:Information Networking
    • /
    • v.27 no.2
    • /
    • pp.149-159
    • /
    • 2000
  • In mobile computing environments, invalidation and propagation method based on broadcasting is used to transmit the information for cache maintenance of mobile hosts. Previous researches generally adopted invalidation method that easily adapts to the limited network bandwidth and the frequent disconnection. But the invalidation of frequently accessed data causes the contention on the wireless network with the increasing cache requests. Although the propagation method can reduce the cache requests, the high probability of broken message or loss of message is the main factor that degrades the system performance. To resolve these problems, we propose adaptive cache maintenance scheme that dynamically adjusts the broadcasting ratio of invalidation and propagation, according to the wireless network connection states. The proposed scheme broadcasts the propagation message in stable connection state, so it can reduce the cache requests and server response time. With the decreasing available network bandwidth by the frequent partial disconnection and disconnection, the proposed scheme dynamically increases the broadcasting ratio of the invalidation messages to minimize the broken message or the loss of message probability. Consequently, the proposed scheme resolves the problems which arise in the invalidation or propagation method in mobile computing environments.

  • PDF

Effects of Behavioral and Emotional Regulation on Preschool Children's Peer Play Behavior: Focusing on Gender Differences (유아의 행동규제 및 정서규제 능력이 또래 놀이행동에 미치는 영향: 성별에 따른 차이를 중심으로)

  • Sung, Mi Young
    • Human Ecology Research
    • /
    • v.52 no.5
    • /
    • pp.541-549
    • /
    • 2014
  • The purpose of this study was to analyze the effects of preschool children's behavioral and emotional regulation on their peer play behavior, focusing on gender differences. A total of 214 4- and 5-year-old children attending a child care center in South Korea participated in this study. The instruments used in this study were the Child Behavior Rating Scale, Emotion Regulation Checklist, and Penn Interactive Peer Play Scale. The collected data were analyzed using a Student's t -test, Pearson's partial correlation, and multiple regressions with the SPSS software ver. 16.0. The main results of this study are as follows: first, there was a significant gender difference in preschool children's behavioral regulation, emotional control, play interaction, and play disruption. However, there was no gender difference in preschool children's play disconnection. Second, preschool children's emotional control and behavioral regulation had positive effects on their play interaction irrespective of gender. Third, preschool children's emotional instability and emotional control had a positive influence on their play disruption irrespective of gender. Finally, the factors of behavioral regulation and emotional instability significantly predicted the boys' play disconnection, while for the girls, the significant predictor was emotional control. Further, implications for the use of early intervention targeting specific behavioral and emotional regulation problems have been discussed.

A Study on the Unique point about the Tracking at Electrical fire spot (화재현장에서 분석 절차에 따른 전기화재 조사기법 개발)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2130-2131
    • /
    • 2011
  • Electric fire breaks out by various causes such as electric short, overload(over current), leakage current, poor contact, static electricity, insulation deterioration, partial disconnection and etc. In this paper, we studied analysis technique for scientific and systematic judgment for distinction of electricity fire existence and nonexistence, and described about electricity fire cause analysis process for collecting physical evidences. We handled external form analysis, Substance extension analysis, X-ray transmission analysis, cross-section analysis, thermal analysis, chemical structure analysis, surface structure analysis, component analysis, electrical properties analysis, and circuit analysis by analysis technique for electricity fire cause judgment. We expect that analysis technic elevation and correct cause of fire analysis of scene of a fire investigators and analysts through this paper which see help.