• Title/Summary/Keyword: pet care

Search Result 97, Processing Time 0.037 seconds

uPetCare : Ubiquitous Pet-Care System using Web2.0 (uPetCare : 웹2.0을 이용한 유비쿼터스 펫 케어 시스템)

  • Park, Jun-Sung;Lee, Gwi-Ro;Cho, Jin-Sung
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.4
    • /
    • pp.260-264
    • /
    • 2009
  • There have been many studies on u-Healthcare system for human using sensor network systems. In this paper, we design and implement a healthcare system for pets called uPetCare(Ubiquitous Pet-Care System) that can manage the status of pet on the web. The main functions of this system are 1) gathering data using sensor network, 2) multi-hop communication in sensor network, 3) data compression and aggregation at sink node, 4) storing data in web server, 5) real-time data monitoring using AJAX, 6) activity recognition of pet.

Pet Care and Internet Consumption (반려동물 돌봄과 인터넷 소비)

  • Han, Hee-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.9
    • /
    • pp.388-400
    • /
    • 2022
  • This study analyzed the Internet consumption behavior concerning pet care through in-depth interviews with 11 people who take care of pets. In this study, along with owners of domestic companion animals, stray cat caregivers were included as pet consumers, which have not yet been included in this category in existing research. Internet consumption was found to differ between people with dogs and people with cats. In the case of dog owners, they bought a lot of bath products, clothes harnesses, and strollers that were not appropriate for cats. Although the pet-poor phenomenon is known to occur a lot among young consumers, who care for pets behavior at the cost of money spent on themselves, even stray cat caregivers, mostly middle-aged women, are wary of becoming pet-poor. It cannot be said that there are gender differences in online shopping of pet consumers. In general, women, who did mainly Internet shopping, and if they are not used to using the Internet, their husbands made purchases online instead.

A Study on the Pet Soil Removal Effect of Washing Conditions Using a Chemiluminescence Reaction (화학발광 반응을 이용한 세탁조건별 반려동물 오구 제거효과 연구)

  • Park, Jung-Eun;Lee, Jungsoon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.5
    • /
    • pp.840-851
    • /
    • 2021
  • In this study, we used a chemiluminescence reaction to investigate the removal effect of pet soil, such as dog blood, urine and feces. The soiled fabrics were washed with a standard laundry course of 30℃ and a washing time of 30 min and a pet care laundry course of 40-60℃ and a washing time of 100 min. The detergency was evaluated by the surface reflectance and chemiluminescence reaction (bloodstain detection by luminol test and urine-stain and feces-stain detection by UV blacklight test) before and after washing. The surface reflectance results did not show any difference in detergency for both courses, whereas the chemiluminescence reaction did. The detergency of the pet care course compared to the standard course was 101% according to the surface reflectance and 120% according to the chemiluminescence reaction. Therefore, residual stains not detected by surface reflectance can be evaluated through chemiluminescence reaction, and it was confirmed that pet stains can be managed more hygienically by washing for a long time at a high temperature.

The Role of Camera-Based Coincidence Positron Emission Tomography in Nodal Staging of Non-Small Cell Lung Cancer (비소세포폐암의 림프절 병기 결정에서 Coincidence PET의 역할)

  • Lee, Sun-Min;Choi, Young-Hwa;Oh, Yoon-Jung;Cheong, Seong-Cheoll;Park, Kwang-Joo;Hwang, Sung-Chul;Lee, Yi-Hyeong;Park, Chan-H;Hahn, Myung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.642-649
    • /
    • 1999
  • Background: It is very important to determine an accurate staging of the non-small cell lung cancer(NSCLC) for an assessment of operability and it's prognosis. However, it is difficult to evaluate tumor involvement of mediastinal lymph nodes accurately utilizing noninvasive imaging modalities. PET is one of the sensitive and specific imaging modality. Unfortunately PET is limited use because of prohibitive cost involved with it's operation. Recently hybrid SPECT/PET(single photon emission computed tomography/positron emission tomography) camera based PET imaging was introduced with relatively low cost. We evaluated the usefulness of coincidence detection(CoDe) PET in the detection of metastasis to the mediastinal lymph nodes in patients with NSCLC. Methods: Twenty one patients with NSCLC were evaluated by CT or MRI and they were considered operable. CoDe PET was performed in all 21 patients prior to surgery. Tomographic slices of axial, coronal and sagittal planes were visually analysed. At surgery, mediastinal lymph nodes were removed and histological diagnosis was performed. CoDe PET findings were correlated with histological findings. Results: Twenty of 21 primary tumor masses were detected by the CoDe PET. Thirteen of 21 patients was correctly diagnosed mediastinal lymph node metastasis by the CoDe PET. Pathological N0 was 14 cases and the specificity of N0 of CoDe PET was 64.3%. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of N1 node was 83.3%, 73.3%, 55.6%, 91.7%, and 76.2% respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of N2 node was 60.0%, 87.5%, 60.0%,87.5%, and 90.0% respectively. There were 3 false negative cases but the size of the 3 nodes were less than 1cm. The size of true positive nodes were 1.1cm, 1.0cm, 0.5cm respectively. There were 1 false positive among the 12 lymph nodes which were larger than 1cm. False positive cases consisted of 1 tuberculosis case, 1 pneumoconiosis case and 1 anthracosis case. Conclusion: CoDe PET has relatively high negative predictive value in the enlarged lymph node in staging of mediastinal nodes in patients with NSCLC. Therefore CoDe PET is useful in ruling out metastasis of enlarged N3 nodes. However, further study is needed including more number of patients in the future.

  • PDF

A Study on the Design of the Dog Care Robot Using Obstacle Protection Algorithm (장애물 회피 알고리즘을 이용한 반려견 케어 로봇디자인에 관한 연구)

  • Chung, Yong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.12
    • /
    • pp.140-149
    • /
    • 2018
  • Along with the recent increase in national income, social phenomena such as aging due to a decrease in population and an increase in single households are observed. There are also an increasing number of households raising pets in proportion to aging households and the increase in the number of single households, most of which use animal companions to overcome loneliness and boost domestic vitality. As more and more people consider pets as family members, the size of the domestic pet market is also growing. The growing number of pets in older households and single households is not properly managed by care such as food meals and exercise management for pets. It is necessary to research and develop robots that can monitor animal companions remotely, feed a certain amount of food at regular intervals, and manage their health through exercise. Among pet companions, dog selection is the highest. Therefore, this study identified robot research on driving methods, examples of existing pet care systems, and researched pet care robots using obstacle avoidance algorithms. In order to use the snack pay behavior and obstacle avoidance algorithm of the pet animals by applying IoT and we .oPI technology, it is able to use ultrasonic sensors on the front and has four infrared sensors on the back. However, this study does not reflect the characteristics of other pet animals as a study on pet care robots, and it requires continuous observation and testing.

Implementation of a Pet Care Robot Based on Webcam and Smartphone and its Power Management (웹캠과 스마트폰 기반의 반려 동물 돌봄 로봇의 구현 및 전원 관리)

  • Lee, Yoon-Ho;Jeon, Joo-Hyeon;Lee, Na-Eun;Jang, Jea-Moon;Yu, Shin;Joo, Moon G.
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.16 no.1
    • /
    • pp.29-34
    • /
    • 2021
  • We developed a pet care robot that can be controlled outdoors. Through the smartphone application, the pet owners can watch the situation in the house and manipulate the robot to make their pet happy. The video data in the house is transmitted to the application through the webcam installed at the house. The robot can not only perform user's command but also do six basic macro action. The obstacle avoidance function using the current sensor can be activated if the user want to use. When the robot hits to something, it moves back and rotates by arbitrary angle, and then moves forward.

mPetCare : Design and Implementation of Pet Care System based on PublicData (mPetCare : 공공데이터를 활용한 반려동물 케어 시스템 설계 및 구현)

  • Jo, Hyun-Sung;Park, Seok-Cheon;Park, Jun-Sik
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.11a
    • /
    • pp.564-567
    • /
    • 2013
  • 최근 핵가족과 고령화 등의 영향으로 반려동물과 함께 생활하는 사람들이 많아지고 있다. 특히, 1인 가구의 증가로, 외로움을 타는 현대인이 증가하면서 반려동물을 가족으로 인식하는 이들이 많아졌다. 따라서, 본 논문에서는 반려동물의 소유주들이 직면하는 문제점들을 해결하기 위하여 공공데이터를 활용한 반려동물 케어 시스템을 설계 및 구현하고, 이를 통해 반려동물을 원할히 관리 할 수 있도록 하였다.

A Case of Monophasic Fibrous Synovial Sarcoma Confirmed Primary Pulmonary Origin by 18F-FDG PET/CT (PET/CT로 폐에서 기원한 것을 확인한 원발성 단상성 섬유성 활막육종 1예)

  • Lee, Eun A;Lee, Do Young;Kwag, Hyon Joo;Kim, Min Kyung;Oh, Tae Yun;Lim, Si Young;Lim, Seong Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.673-677
    • /
    • 2006
  • Most malignant mesenchymal tumors of the lung are metastases of a primary tumor from elsewhere in the body. A primary pulmonary synovial sarcoma is a very rare neoplasm that accounts for approximately 10% of soft tissue sarcomas and makes up only 0.5% of all primary lung malignancies. We report a case of a primary pulmonary synovial sarcoma in a 60-year old woman. In this case, a lung metastasis was excluded using 18F-FDG PET /CT imaging.

Application of PET in Brain Tumor (뇌종양에서 PET의 임상이용)

  • Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.19-27
    • /
    • 2002
  • The annual incidence of primary brain tumors is 7-19 cases per 100,000 people. The unique capacity of visualizing biochemical processes allows PET to determine functional metabolic activities of the brain tumors. Like other malignant tumors, F-18 FDG has been used commonly in the imaging of brain tumors. FDG PET is valuable in grading malignancy, predicting prognosis, monitoring treatment, differentiating tumor recurrence from radiation necrosis, and detecting primary lesion in metastatric brain tumors. Among amino acids labeled with positron emitters, C-11 methionine is used clinically. Tumor delineation is much better with methionine PET than with FDG PET. Low grade gliomas, in particular, are better evaluated with methionine than with FDG. PET opens another dimension in brain tumor imaging. PET imaging has clearly entered the clinical area with a profound impact on patient care in many indications.