• Title/Summary/Keyword: photographic imaging system

Search Result 12, Processing Time 0.03 seconds

Image Enhancement Algorithm in Imaging Systems for Electronic Photography (전자사진용 화상시스템의 화상개선 알고리즘)

  • 박용주;김지홍
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.20 no.1
    • /
    • pp.133-145
    • /
    • 2002
  • A study on electronic imaging system with silver halide photography emulation by a parametric approach will be introduced. The study contains the comparison analysis between silver halide imaging process and electronic imaging process, the characterization of the detailed process in those imaging chains, such as exposure, developing, photographic print and the other photographic and digital process. We investigated the characteristic curve between optical density and the amount of exposure in silver halide and digital photography systems. Under wide range of exposure condition, several sensitometric parameters were obtained via studio and outdoor photographic experiments with conventional photography and a digital camera. whose experimental results will be shown. Finally, the comparison between electronic imaging and conventional photography via silver halide photography emulation and modeling the silver halide process wi13 be discussed.

  • PDF

Multimodal Digital Photographic Imaging System for Total Diagnostic Analysis of Skin Lesions: DermaVision-Pro (다모드 디지털 사진 영상 시스템을 이용한 피부 손상의 진단적 분석에 대한 연구 : DermaVision-Pro)

  • Bae, Young-Woo;Kim, Eun-Ji;Jung, Byung-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.153-154
    • /
    • 2008
  • Digital photographic analysis is currently considered as a routine procedure in clinic because periodic follow-up examinations can provide meaningful information for diagnosis. However, it is impractical to separately evaluate all suspicious lesions with conventional digital photographic systems, which have inconsistent characteristics of the environmental conditions. To address the issue, it is necessary for total diagnostic evaluation in clinic to integrate conventional systems. Previously, a multimodal digital photographic imaging system, which provides a conventional color image, parallel and cross polarization color images and a fluorescent color image, was developed for objective evaluation of facial skin lesions. Based on our previous study, we introduce a commercial product, "DermaVision-PRO," for routine use in clinical application in dermatology. We characterize the system and describe the image analysis methods for objective evaluation of skin lesions. In order to demonstrate the validity of the system in dermatology, sample images were obtained from subjects with various skin disorders, and image analysis methods were applied for objective evaluation of those lesions.

  • PDF

Optimized Optomechanical Anti-Aliasing Filter for Digital Camera Photography

  • Lee, Sang Won;Chang, Ryungkee;Moon, Sucbei
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.456-466
    • /
    • 2015
  • We investigated an anti-aliasing (AA) filter for digital camera photography by which the excessively high-frequency components of the image signal are suppressed to avoid the aliasing effect. Our optomechanical AA filter was implemented by applying rapid relative motions to the imaging sensor. By the engineered motion blur of the mechanical dithers, the effective point-spread function (PSF) of the imaging system could be tailored to reject the unwanted high-frequency components of the image. For optimal operations, we developed a spiral filter motion protocol that could produce a Gaussian-like PSF. We experimentally demonstrated that our AA filter provides an improved filtering characteristic with a better compromise of the rejection performance and the signal loss. We also found that the pass band characteristic can be enhanced further by a color-differential acquisition mode. Our filter scheme provides a useful method of digital photography for low-error image measurements as well as for ordinary photographic applications where annoying $moir{\acute{e}}$ patterns must be suppressed efficiently.

A Study on the Rotating Displacement Measurement of Rigid Body by ESPI Method (ESPI법에 의한 강체 회전 변위 측정에 관한 연구)

  • 김경석;홍명석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.125-133
    • /
    • 1993
  • Electronic Speckle Pattern Interferometry(ESPI) using a CW laser, a video system and image processor was applied to the rotating displacement of rigid body. ESPI require no special surface preparation or attachments and displacements between any two arbitrary points on the surface can be measured. The characteristic speckle pattern formed when imaging a scattering surface illuminated by laser light retains phase information, which can be used for interferometric measurement of surface displacement. The application of this principle to measuring in-plane displacement resolved in one direction is described, together with the novel use of television equipment to detect and process the information contained in the speckle pattern. This is faster, and more convenient and versatile than customary photographic methods.

  • PDF

A Study on the Imaging Formation in Ferroelectric Film

  • 조국래
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.14 no.1
    • /
    • pp.133-146
    • /
    • 1996
  • Eastman Kodak Co. has announced the concept of photo CD System in September, 1990 With Photo CD System technology, Kodak Co. Furnishes a convinent way to view, use and store photographic images. The heart of this system is a format provides progressively higher levels of image quality to meet the demands of NTSC, PAL and HDTV video displays as well as hard copy output. Also, image professionals are instrested in the capability of Photo CD, such as a way to store image at low cost in a high-resolution digital format that can be played back on different computer platforms. Many editors wish to use Photo CD images in the printing and publishing industry. However, Photo CD images were not processed detail enhancement and some others to use in the lithographic offset printing. Therefore, in this paper discribes a method to improve the sharpness of Photo CD images.

  • PDF

Design of Interactive Photo Mosaic Imaging System (인터랙티브 포토 모자이크 영상 시스템의 설계)

  • Kim, Do-Hee;Choi, Yoo-Joo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2017.06a
    • /
    • pp.241-242
    • /
    • 2017
  • 최근 영화, 광고, 미디어 전시 등의 분야에서 다양한 특수 효과가 처리된 장면의 연출이 적용되고 있다. 특히, 미디어 전시, 공연 등에서는 관객 혹은 공연자의 움직임에 반응하는 예술적 영상의 인터랙티브 표현들이 시도되고 있다. 이에 본 논문에서는 광고, 전시 등에서 효과적으로 활용될 수 있는 인터랙티브 포토 모자이크(photographic mosaic) 영상을 생성하는 시스템을 제안하였다.. 제안 시스템에서는 관객의 출현을 인지하고, 관객의 얼굴을 자동으로 캡쳐하여 관객의 얼굴 사진을 이용한 모자이크 영상을 실시간으로 생산한다. 이 때, 흥미 유발을 위하여 모자이크를 구성하는 관객의 얼굴 사진 조각들이 움직임을 가지는 작은 사각의 입자로 표현되어 서로가 충돌하며 자연스러운 움직임을 통하여 하나의 영상으로 맞춰가는 모습이 보여지도록 하였다.

  • PDF

Generation of the Ortho-Rectified Photo Map and Analysis of the Three-Dimensional Image Using the PKNU 2 Imagery (PKNU2호 영상을 이용한 정사영상 지도 제작 및 3차원 입체 분석)

  • Lee, Chang Hun;Choi, Chul Uong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.7 no.4
    • /
    • pp.77-87
    • /
    • 2004
  • It is important for hydrographers to extract the accurate cross section of a river for the hydrographical analysis of the topography. Aerial photographs were used to extract the cross section of a river for the advantages of the accuracy and economical efficiency in this study, while the direct measurement has been used in existing studies. An ortho-rectified photo map using imageries taken by the PKNU 2 (High-resolution, multi-spectral, aerial photographic system developed by our laboratory) was generated using the surveyed data and a digital map. The cross section of a river that was obtained from the ortho-rectified by the surveyed Kinematic data of GPS was compared with the result using ImageStation stereo-plotter of corp. Z/I Imaging. As a result of this study, the RMSE in the ortho-rect process using the surveyed GPS data was lowered as from 5.5788 pixels (about 2m) to 2.84 (about 1m) in comparison with it in the process using a digital map. The surveyed kinematic GPS in extraction of the cross section of a river was excellent as 6.6cm of the planimetric and precision in the confidence level of 95%. The correlation coefficient between the result from the using stereo-plotter and the extraction of cross section of a river using aerial photos was 0.8 hydrographical acquisition of it using PKNU 2 imagery will be possible.

  • PDF

A study on Protector Performance Evaluation According to X-ray Scattering Distribution of Portable Radiation System (이동형 방사선 발생장치 차폐물 설치에 관한 연구)

  • Kim, Hyong-Gyun;Sung, Dong-Keon;Cho, Kyong-Mi;Kim, Sang-Beom;Kim, Jae-Young;Choi, Jun-Ho
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.85-92
    • /
    • 2009
  • This study, "The study about performance evaluations of mobile cover for X-ray's diffusion and distribution in mobile radiation" is based on the rules of mobile defense apparatus for radiation producer in 2006. To use the mobile cover for X-ray for diagnosis has been compulsory in common wards except operation rooms, emergency rooms and intensive care units. we have confirmed the effect in arbitrary shielding material after Qualitiy Control was carried out for accuracy in an experiment of mobile photographing equipment. The performance evaluation was conducted with the fabrics of selenium, 0.2 mmPb, 0.1 mmPb and aluminiums. Considering the result, we choosed 0.1 mmPb and attached cover to mobile photographing equipment. We have finished making the cover after drew up the draft to attach cover to mobile photographing equipment through the modeling and the structural analysis. the process of the study is that we assembled the manufactured structures and carried out the practical experiment to take the photograph after attaching the fabric of 0.1 mmPb to mobile photographing equipment. It is need of additional thesises hereafter that we compare the result between the part to improve for safety besides convenience in photographic experiment about clinical radiation and the effect of covering the diffusion in condition attached the cover.

  • PDF

Investigation on the Sauter Mean Diameter of an Air-Assisted Fuel Injector -Operating Parameter Consideration (운전조건에 따른 공기보조 분사기의 Sauter 평균입경에 대한 고찰)

  • 장창수;최상민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.42-50
    • /
    • 2000
  • Drop size distribution of an air-assisted fuel injector(AAFI) was investigated. Influence of parameters such as ambient air density supply pressure and air-liquid mass ratio(ALR) was examined through both measurement and analysis. The Sauter mean diameter$D_{32}$ varied from 9 to 25$\mu$m throughout all experimental conditions. An empirical correlation for droplet size was obtained. Analytical correlations for predicting $D_{32}$ with respect to operating conditions were also derived through energy consideration and introduction of a simplified model of the from the empirical fitting was adapted to the original equation the proposed correlation in this study matched more closely with measured results. The current correlation exhibited a favorable study matched more closely with measured results. The current correlation exhibited a favorable prediction for $D_{32}$ compared to that by the empirical correlation at selected experimental conditions so that it may be used to predict atomization performance of the AAFI at operating conditions which was not covered in the measurements. After validation the analytical equation was applied to survey the feasible operating conditions for gasoline direct injection application.

  • PDF

An Image Quality Evaluation Model for Optical Strip Signal-to-Noise Ratio in the Target Area of High Temperature Forgings

  • Ma, Hongtao;Zhao, Yuyang;Feng, Yiran;Lee, Eung-Joo;Tao, Xueheng
    • Journal of Multimedia Information System
    • /
    • v.8 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • Under the time-varying temperature, the high-temperature radiation of forgings and the change of reflection characteristics of oxide skin on the surface of forgings lead to the difficulty of obtaining images to truly reflect the geometric characteristics of forgings. It is urgent to study the clear and reliable acquisition method of hot forging feature image under time-varying temperature to meet the requirements of visual measurement of hot geometric parameters of forgings. Based on this, this chapter first puts forward the quality evaluation method of forging feature image, which provides guarantee for the accurate evaluation of feature image quality. Furthermore, the factors that affect the image quality, such as the radiation characteristics of forgings and the photographic characteristics of cameras, are analyzed, and the imaging spectrum which can effectively suppress the radiation intensity of forgings is determined. Finally, aiming at the problem that the quality of image acquisition is difficult to guarantee due to the drastic change of radiation intensity of forgings under time-varying temperature, an image acquisition method based on minimum signal-to-noise ratio (SNR) based laser light intensity adaptation is proposed, which significantly improves the definition of feature light strips in forging images at high temperature, and finally realizes the clear acquisition of feature images of large-scale hot forging under time-varying temperature.