• Title/Summary/Keyword: plasma diagnostic

Search Result 198, Processing Time 0.03 seconds

Laser Thomson Scattering for Measuring Plasma Temperature and Density in ICP

  • Seo, Byeong-Hun;Yu, Sin-Jae;Kim, Jeong-Hyeong;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.144-144
    • /
    • 2011
  • Diagnostics of plasma density and temperature play an important role for monitoring plasma processing and Laser Thomson scattering is a one of the most accurate diagnostic technique for measuring plasma density and temperature because of none-perturbation to plasma among various diagnostic techniques invented to measure plasma density and temperature. I will briefly review Laser Thomson scattering experiment performed in KRISS and difficulties for measuring the electron velocity distribution such as Gaussian due to low signal-to-noise ratio with showing results that we got until now. This work is an intermediate step in a process that we will get a reliable data which shows physical phenomenon of plasma compared with other diagnostic techniques and results.

  • PDF

Radiographic features of plasma cell leukemia in the maxilla: A case report

  • Wong, Phillip;Kashtwari, Deeba;Nair, Madhu K.
    • Imaging Science in Dentistry
    • /
    • v.46 no.4
    • /
    • pp.273-278
    • /
    • 2016
  • Plasma cell leukemia (PCL) is an aggressive form of multiple myeloma where there is hematogenous spread of abnormal plasma cells into the periphery. This is opposed to multiple myeloma, where the abnormal plasma cells stay in the bone marrow. PCL is more common in males than females, and is also more common in African-Americans than Caucasians. Signs and symptoms of PCL include, but are not limited to, renal insufficiency, hypercalcemia, anemia, lytic bone lesions, thrombocytopenia, hepatomegaly, and splenomegaly. Here, we discussed a case of a 71-year-old Caucasian female recently diagnosed with primary PCL with radiographic features of this disease throughout the body, with an emphasis on the maxillofacial skeleton and relevance from a dental standpoint.

Laser Diagnostic in a Plasma Display Panel Discharge Cell

  • Choi, Young-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.21-22
    • /
    • 2000
  • Laser diagnostic method in a plasma display discharge cell was introduced. The information of electric field, potential and electron temperature et al. in the surface of plasma display panel can be measured using laser induced fluorescence spectroscopy. However, because of the very small discharge dimension of ${\sim}$ 100 ${\mu}m$, the measurement attempt has almost not been performed. In this paper, the direct measurement possibility of the parameters and the recent work of electric field measurement are demonstrated in the plasma display panel.

  • PDF

Fast Measurement using Wave-Cutoff Method

  • Seo, Sang-Hun;Na, Byeong-Geun;Yu, Gwang-Ho;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF

Measurement of the ICRH antenna phasing using antenna strap probe based diagnostic system in EAST tokamak

  • Liu, L.N.;Liang, Q.C.;Yang, H.;Zhang, X.J.;Yuan, S.;Mao, Y.Z.;Zhang, W.;Zhu, G.H.;Wang, L.;Qin, C.M.;Zhao, Y.P.;Cheng, Y.;Zhang, K.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3614-3619
    • /
    • 2022
  • To operate the ion cyclotron resonance heating (ICRH) antennas in a better heating state and produce relatively low impurities, it is necessary to control the antenna spectrum by changing the antenna phasing. As the electrical length of the antenna feeding transmission lines is changing as a matter of the standing wave pattern at the ceramic supports, 90° elbows, T-connectors and antenna loops, we chose to measure the current at the grounding points of the antenna loops by antenna strap probe. The voltage drops along a small, several millimeter-long paths at the end of the antenna loops give a signal that is proportional to the current in the antenna loop. Through the simulation of the antenna strap probe and the actual measurement of the antenna phasing under vacuum conditions, the reliability of the antenna strap probe based diagnostic system have been successfully proved. Moreover, this system was successfully applied to the ICRH daily experiments in the spring of 2021. In the near future, the active real-time feedback control of the antenna phasing system will be developed based on this diagnostic system in the EAST tokamak.

Plasma Osteopontin Is a Useful Diagnostic Biomarker for Advanced Non-Small Cell Lung Cancer

  • Han, Seon-Sook;Lee, Seung-Joon;Kim, Woo Jin;Ryu, Dong Ryeol;Won, Jun Yeon;Park, Shinyoung;Cheon, Myeong Ju
    • Tuberculosis and Respiratory Diseases
    • /
    • v.75 no.3
    • /
    • pp.104-110
    • /
    • 2013
  • Background: Osteopontin (OPN) and carbonic anhydrase IX (CAIX), which are expressed on the surface of tumor cells, are associated with hypoxia during tumor development and progression. However, the roles of these proteins in the plasma of patients with non-small cell lung cancer (NSCLC) are poorly understood. Herein, we hypothesized that plasma OPN and CAIX levels could be used as diagnostic and prognostic tumor markers in patients with NSCLC. Methods: Fifty-three patients with NSCLC and 50 healthy control subjects were enrolled. We selected controls without malignancy and matched them with NSCLC patient cases according to age and gender. Blood samples were collected at the time of diagnosis; the plasma levels of OPN and CAIX were measured by enzyme-linked immunosorbent assays. Results: The plasma levels of OPN in the patients with NSCLC were significantly elevated as compared to those in the controls (p=0.016). However, there was no difference in the plasma level of CAIX between the NSCLC patients and controls. NSCLC patients with a distant metastasis had a remarkable increase in plasma OPN compared with patients without metastasis (p=0.026), but no such correlation was found for CAIX. There was no difference in overall survival rates according to the plasma level of OPN between the two groups (by Kaplan-Meier survival analysis). Conclusion: Plasma OPN levels were elevated in patients with NSCLC as compared with the controls, with greater elevation of OPN levels in the advanced stages of disease. Therefore, plasma OPN may have utility as a diagnostic, but not prognostic, biomarker of advanced NSCLC.

Fabrication and Simulation of Fluid Wing Structure for Microfluidic Blood Plasma Separation

  • Choe, Jeongun;Park, Jiyun;Lee, Jihye;Yeo, Jong-Souk
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.196-202
    • /
    • 2015
  • Human blood consists of 55% of plasma and 45% of blood cells such as white blood cell (WBC) and red blood cell (RBC). In plasma, there are many kinds of promising biomarkers, which can be used for the diagnosis of various diseases and biological analysis. For diagnostic tools such as a lab-on-a-chip (LOC), blood plasma separation is a fundamental step for accomplishing a high performance in the detection of a disease. Highly efficient separators can increase the sensitivity and selectivity of biosensors and reduce diagnostic time. In order to achieve a higher yield in blood plasma separation, we propose a novel fluid wing structure that is optimized by COMSOL simulations by varying the fluidic channel width and the angle of the bifurcation. The fluid wing structure is inspired by the inertial particle separator system in helicopters where sand particles are prevented from following the air flow to an engine. The structure is ameliorated in order to satisfy biological and fluidic requirements at the micro scale to achieve high plasma yield and separation efficiency. In this study, we fabricated the fluid wing structure for the efficient microfluidic blood plasma separation. The high plasma yield of 67% is achieved with a channel width of $20{\mu}m$ in the fabricated fluidic chip and the result was not affected by the angle of the bifurcation.

Changes of Plasma Lidocaine Concentrations after Stellate Ganglion Block according to Volume-changes of 1% Lidocaine (성상신경절차단시 주입된 1% Lidocaine 양에 따른 혈중 Lidocaine 농도 변화)

  • Song, Sun-Ok;Suh, Yung-Ho
    • The Korean Journal of Pain
    • /
    • v.14 no.1
    • /
    • pp.26-31
    • /
    • 2001
  • Background: Sympathetic blocks with local anesthetics are used to differentiate sympathetically- maintained pain (SMP) from sympathetically-independent pain (SIP). However, systemic lidocaine is also used in the management of neuropathic pain. Therefore, there may be possibility of a false positive response in relieving their pain by systemic absorption of lidocaine following a diagnostic sympathetic block in patients with SIP. In this study, we measured the plasma lidocaine concentrations after a stellate ganglion block (SGB) using three volumes of 1% lidocaine. Methods: This prospective, crossover study was performed in 3 patients who experience sudden hearing loss and in 4 volunteers. Each person received SGB three times using three different volumes (6 ml, 12 ml and 16 ml) of 1% lidocaine at one week intervals. SGB was performed using a 23 G butterfly needle via a paratracheal approach by two persons. Two ml of venous blood was obtained from a prepared contra-lateral sided venous route at 1, 3, 5, 7, 10, 20 and 60 min after SGB. Plasma lidocaine level was analyzed by immunoassay. Results: Mean plasma lidocaine concentrations correlated well with the volumes of 1% lidocaine used in SGB; larger volumes showed higher concentrations (P < 0.01). Mean peak plasma concentrations were $1.08{\pm}0.18$ in 6 ml, $1.90{\pm}0.47$ in the 12 ml and $2.74{\pm}0.67{\mu}g/ml$ in the 16 ml groups (P < 0.01). The mean time to reach peak plasma concentration was not significantly different between the three groups. Conclusions: The peak plasma lidocaine concentrations in SGB using large volume were found to be similar to that of IV lidocaine infusion in the management of neuropathic pain. These data suggest that diagnostic sympathetic block may result in many false positive responses for SMP. Part of its effect may be related to systemic local anesthetic absorption and not to a sympathetic block. Therefore, physicians may be required to use optimal volumes and minimal concentration of local anesthetic in diagnostic sympathetic block procedures and also make a careful assessment of the performance of a permanent sympathetic block.

  • PDF

Polyamines and Their Metabolites as Diagnostic Markers of Human Diseases

  • Park, Myung Hee;Igarashi, Kazuei
    • Biomolecules & Therapeutics
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Polyamines, putrescine, spermidine and spermine, are ubiquitous in living cells and are essential for eukaryotic cell growth. These polycations interact with negatively charged molecules such as DNA, RNA, acidic proteins and phospholipids and modulate various cellular functions including macromolecular synthesis. Dysregulation of the polyamine pathway leads to pathological conditions including cancer, inflammation, stroke, renal failure and diabetes. Increase in polyamines and polyamine synthesis enzymes is often associated with tumor growth, and urinary and plasma contents of polyamines and their metabolites have been investigated as diagnostic markers for cancers. Of these, diacetylated derivatives of spermidine and spermine are elevated in the urine of cancer patients and present potential markers for early detection. Enhanced catabolism of cellular polyamines by polyamine oxidases (PAO), spermine oxidase (SMO) or acetylpolyamine oxidase (AcPAO), increases cellular oxidative stress and generates hydrogen peroxide and a reactive toxic metabolite, acrolein, which covalently incorporates into lysine residues of cellular proteins. Levels of protein-conjuagated acrolein (PC-Acro) and polyamine oxidizing enzymes were increased in the locus of brain infarction and in plasma in a mouse model of stroke and also in the plasma of stroke patients. When the combined measurements of PC-Acro, interleukin 6 (IL-6), and C-reactive protein (CRP) were evaluated, even silent brain infarction (SBI) was detected with high sensitivity and specificity. Considering that there are no reliable biochemical markers for early stage of stroke, PC-Acro and PAOs present promising markers. Thus the polyamine metabolites in plasma or urine provide useful tools in early diagnosis of cancer and stroke.

Modeling and Experimental Study of Radio-frequency Glow Discharges and Applications for Plasma Processing

  • Kang, Nam-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.179-179
    • /
    • 2012
  • Low pressure radio-frequency glow discharges are investigated using theoretical modeling and various experimental diagnostic methods. In the calculations, global models and transformer models are developed to understand the chemical kinetics as well as the electrical properties such as the effective collision frequency, the heating mechanism and the power transferred to the plasma electrons. In addition, Boltzmann equation solver is used to compensate the effect of the electron energy distribution function (EEDF) shape in the global model, and the general expression of energy balance for non-Maxwellian electrons is developed. In the experiments, a number of traditional plasma diagnostic methods are used to compare with calculated results such as Langmuir probe, optical emission spectroscopy (OES), optical absorption spectroscopy (OAS) and two-photon absorption laser-induced fluorescence (TALIF). These theoretical and experimental methods are applied to understand several interesting phenomena in low pressure ICP discharges. The chemical and physical properties of low pressure ICP discharges are described and the applications of these methods are discussed.

  • PDF