• Title/Summary/Keyword: protector for construction surface

Search Result 3, Processing Time 0.021 seconds

A study on contaminant reduction performance of the adsorption protector for construction surface (흡착보양재의 오염물질방출 저감성능에 관한 연구)

  • Heo, Jung-Yong;Choi, Chang-Ho;Lee, Yun-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.714-719
    • /
    • 2008
  • In a domestic construction field, after floor is constructed, protector for construction surface is set up to prevent the surface of the floor being scratched and polluted. However, the problem is that contaminants discharged with the removal of the protector for construction surface exert a bad influence for the indoor air quality. In the research, it tested to the contaminant reduction performance of the adsorption protector for construction surface using powder of charcoal by the alternative proposal of such protectors for construction surface

  • PDF

A Study on Initial Control Performance of the Adsorption Protector for Construction Surface about Contaminant (흡착보양재 적용에 따른 실내 오염물질 초기제어 성능에 관한 연구)

  • Heo, Jung-Yong;Choi, Chang-Ho;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.4
    • /
    • pp.229-235
    • /
    • 2009
  • In a domestic construction field, floor surface must be covered not to be scratched and polluted by protector until resident comes in. However this protector restricts the contaminant to leave from floor surface. So when the protector is removed, much contaminant is emitted from the floor surface to inside and makes a bad influence on the indoor air quality, In this research, it will be tested the reduction performance of contaminant between a normal protector and a contaminant absorption protector using charcoal powder.

A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance (콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구)

  • Jang, Seo-Yong;Kim, Jong-Ryeol;Shin, Yun-Sup;Ma, Bong-Duk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.163-170
    • /
    • 2006
  • Recently, piezocone penetration test is frequently used in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. In this study, the correlation of standard penetration test, piezocone penetration test and driving resistance of vertical drain is analyzed in order to increase the confidence for determination of soft ground depth. As the results of each zone, the relation between standard penetration test and piezocone penetration test shows qc=(1.09~1.63)N at the soft ground, determined by 5/30 N value which is decided for soft ground criteria. And qc=(1.21~1.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. And driving resistance of vertical drain is $65{\sim}70kgf/cm^2$ which is equal to $10kgf/cm^2$ of cone penetration resistance.