• Title/Summary/Keyword: pulsed doppler ultrasound

Search Result 19, Processing Time 0.03 seconds

Accuracy of Pulsed Doppler Ultrasound Velocity Measurements : In Vitro Flow Phantom Study (Pulsed Doppler 초음파속도측정의 정확도 판정 : 유동 phantom 연구)

  • Kim, Young-Ho;Min, Byung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.153-156
    • /
    • 1994
  • An in vitro steady flow experiment was performed in order to test the accuracy of velocity measurement obtained through a pulsed Doppler echocardiography. A flow phantom was designed for the use in a wide velocity range at a given flow rate. The results showed that the pulsed Doppler velocity measurement obtained in this flow phantom is accurate at low flow rates. However, ultrasound velocity measurement should be performed under a careful considerations of PRF and Doppler gain settings, especially at higher flow rates.

  • PDF

A Study on the Pulsed Doppler System using Quadrature-Sampling Method in R.F. Range (RF (Radio Frequency) 영역에서의 Quadrature sampling을 이용한 펄스 도플러 장치의 개발에 관한 연구)

  • Kim, Jae-Kyoung;Jeong, Taek-Seob;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.297-300
    • /
    • 1988
  • The ultrasound Doppler effect is used for measuring the velocity of the bloodflow in an artry. Because of the range information, the pulsed doppler system is most commonly used. In this paper, we propose a new pulsed doppler system which uses a quadrature sampling method in R.F. range in order to detect the bloodflow direction and to simplify the compexity of hardware. The pulsed doppler system using quadrature sampling method in R.F. range eliminates In-phase, Quadrature phase channel balancing problem at demodulator. In addition, the improved pulsed Doppler system shows the possibility of serial processing.

  • PDF

Development of Ultrasound Sector B-Scanner(III)-Pulsed Ultrasonic Doppler System- (초음파 섹터 B-스캐너의 개발(III)-초음파 펄스 도플러 장치-)

  • 백광렬;안영복
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.139-146
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

A Study on Ultrasound Pulsed Doppler Systems for Sending the Blood Flow (혈류 진단을 위한 초음파 펄스 도플러 시스템에 관한 연구)

  • Kim, Seong-Ryul;Kim, Jin-Ha;Park, Song-Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.5
    • /
    • pp.33-40
    • /
    • 1984
  • In the conventional pulsed doppler system, gated CW is used to excite a ultrasonic transducer so that a group of linear RF amplifiers are required to excite a ultrasonic array transducer in the scanning pulsed doppler system. A pulsed doppler system without linear high voltage RF amplifiers, which excites the transducer impulsively, is studied theoretically and experimentally. In this paper, an experimental 8-channel pulsed doppler system is implemented, which uses quadrature defection to detect the direction of motion and can compensate the attenuation effect. The designed pulsed doppler system shows the possibility of real time multichannel doppler flow meter.

  • PDF

Blood Flow in an Aortic Bifurcation Model: Pulsed Doppler Ultrasound and Laser Doppler Anemometry Studies (대동맥분기에서의 혈액유동: 맥도플러초음파 및 레이저도플러계측기를 사용한 연구)

  • Kim, Young-H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.43-46
    • /
    • 1992
  • $\underline{In\;vitro}$ velocity measurements were made using both the pulsed Doppler ultrasound (PDU) machine and laser Doppler anemometer (LDA) system in order to investigate the flow characteristics near the aortic bifurcation. Velocities measured from the PDU machine was in good agreement with those from the LDA. The flow in the daughter branches was three-dimensional with a secondary flow. The oscillating wall shear stress with this secondary fluid motion is well correlated with the localization of the atherosclerosis.

  • PDF

Three-Dimensional Flow in an Aortic Bifurcation Model: Comparison of In Vitro Experiments and Numerical Simulation (대동맥 분기관 모델 내 삼차원 유동: In vitro 실험과 수치해석의 비교)

  • Kim, Young-H.;Seo, Sang-H.;Ryu, Sang-S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.15-18
    • /
    • 1995
  • Three-dimensional steady and pulsatile flow experiments and numerical simulations have conducted to investigate the flow characteristics in the aortic bifurcation model. In vitro velocity measurements were made using both laser Doppler anemometry and pulsed Doppler ultrasound velocimetry. In this study, flow phenomena in the aortic bifurcation model are discussed extensively and the numerical results are compared with experimental results.

  • PDF

Estimation of portal blood flow using pulsed doppler ultrasound in the anesthetized dog (도플러 초음파를 이용한 개에서 마취에 따른 간문맥 혈류량 변화의 측정)

  • Lee, Young-won
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.659-663
    • /
    • 1998
  • Portal bood flow was measured with pulsed Doppler ultrasound in twenty anesthetized dogs. In anesthetized dogs with xylazine HCl, the average of portal blood flow velocity was reduced($11.68{\pm}1.55cm/sec$ vs. normal $16.67{\pm}1.77cm/sec$). Average portal blood flow was also decreased compared to normal($28.36{\pm}11.61ml/min/kg$ vs. normal $43.12{\pm}14.46 ml/min/kg$). And congestion index was increased($0.0368{\pm}0.0117cm{\cdot}sec$) vs. normal $0.0297{\pm}0.0062cm{\cdot}sec$). In anesthetized dogs with ketamine HCl, portal blood flow velocity was slightly increased ($22.62{\pm}2.53cm/sec$ vs. normal $16.67{\pm}1.77cm/sec$. Also mean portal blood flow was slightly increased($43.12{\pm}14.46ml/min/kg$ vs. normal $55.32{\pm}19.99ml/min/kg$). In anesthetized dogs with tiletamine and zolazepam, portal blood flow velocity and portal blood flow were unchanged.

  • PDF

Differentiation of Malignant and Benign Cervical Lymph Nodes with Color and Pulsed Doppler Ultrasonography (색채 및 펄스 도플러 초음파를 이용한 경부 림프절의 양성과 악성의 감별)

  • Lee Kang-Dae;Lee Bong-Hee;Lee Yun-Woo;Lee Hwan-Ho;Ahn Kyong-Mo;Lee Young-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.17 no.1
    • /
    • pp.19-25
    • /
    • 2001
  • Objectives: The clinical efficacy of the color and pulsed Doppler ultrasound with spectral waveform analysis for differentiation of malignant from benign cervical lymphadenopathy was prospectively evaluated in cervical lymphadenopathy. Materials and Methods: Color and pulsed Doppler ultrasound examination was prospectively performed in 32 cervical lymph nodes in 28 patients. These 10 nodes from 10 patients were malignant and 22 nodes from 18 patients were benign, proved by operation, biopsy, and follow-up examination. Another 12 lymph nodes from 12 normal volunteers were evaluated as control group. The peak systolic velocity (PSV), minimal diastolic velocity (MDV) , and resistive indexes (RI) of arterial flows within the 32 lymph nodes were assessed to differentiate the malignant from benign nodes with pulsed Doppler ultrasonography. The results were qualitified with one-way ANOVA and Bonferroni method of multiple comparison. Results: The mean values of PSV of malignant, benign, and control nodes were 38.2(10.1-134)cm/sec, 23.3(9-38.5) cm/sec and 11.8(6.7-18.1) cm/sec, respectively. The mean values of MDV of them were 0.9(-7.5-10.7)cm/sec, 9.7(2.9-18.6)cm/sec and 6.5(3.7-9.3)cm/sec, respectively. However, there was no statistical significance in differentiation of malignant from benign nodes with PSV and MDV. The mean values of RI of malignant, benign, and control nodes were 0.99(0.80-1.30), 0.59(0.46-0.77) and 0.45(0.38-0.50), respectively. RI value of 0.8 is suggestive value for discrimination of malignant from benign lymphadenopathy during examination of color Doppler ultrasound of cervical lymphadenopathy. Conclusion: Color and pulsed Doppler ultrasound examination with spectral waveform analysis may be quite helpful in the differentiation between benign and malignant alterations of cervical lymph nodes.

  • PDF

Developement of Efficient Algorithm to Eliminate Aliasing of Ultrasonic Pulsed Wave Doppler Signal (초음파 Pulsed Wave 도플러 신호의 Aliasing 제거를 위한 효율적인 알고리즘 개발)

  • Kim, G.D.;Hwang, J.S.;Ahn, Y.B.;Song, T.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.213-214
    • /
    • 1998
  • The important role of the ultrasonic Doppler system in the modem clinical medicine is to provide the clinical information of the vascular system. The ultrasonic pulsed wave(PW) Doppler system, a kind of the ultrasound Doppler system, is more available than the ultrasonic continuous wave(CW) Doppler system because it can evaluate the velocity and the direction of blood flow as well as the depth of vessel. However, the ultrasonic PW Doppler system has the disadvantage that the range of evaluating velocity of blood flow is limited(Nyquist limit). In order to solve this limit, we propose the algorithm for eliminating this aliasing in this paper. In addition, we propose the efficient signal processing algorithm.

  • PDF

A study on the development of Pulsed Doppler System using Auto-Correlation (Auto-Correlation을 이용한 펄스 도플러 시스템에 관한 연구)

  • Lim, Chun-Sung;Rang, Chung-Shin;Lee, Hang-Sei;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.705-708
    • /
    • 1988
  • Ultrasound Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. Pulsed Doppler System uses Phase detector and zerocrossing method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time domain, had been fabricated. But time-domain analyzing such as audio evaluation and zerocrossing detection for instantaneous and mean frequency measurement doesn't, provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency domain technique to improve system performance. In this paper, we describe a unit which is composed of Pulsed Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of blood Signal.

  • PDF