• 제목/요약/키워드: push over test

검색결과 42건 처리시간 0.023초

Over The Top(OTT) 서비스 전환의도에 영향을 미치는 Push-Pull-Mooring 요인에 대한 실증적 분석 (An Empirical Analysis of Push-Pull-Mooring Factors Affecting on Switching Intention to Over the Top(OTT) Services)

  • 박현선;김상현
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제30권4호
    • /
    • pp.71-94
    • /
    • 2021
  • Purpose The purpose of this study is to verify impacts of factors, representing Push-Pull-Mooring(PPM) on switch intention to OTT(Over-The-Top) service in demand for content and to find relationship between factors through empirical analysis. Design/methodology/approach This study designed a research model by deriving factors affecting the intention to switch on OTT service based on the Push-Pull-Mooring framework and researches on OTT service. To test the hypothesis, a total of 357 responses were collected from individuals with experience in using OTT service and analyzed using SPSS26 and SmartPLS3.0. Findings According to the empirical analysis result, this study confirmed that the push, pull, and mooring factors proposed in this study had a significant effect on switching intention on OTT service. In addition, this study confirmed that both low switching cost and need for variety had a significant effect except for hypothesis H8.

Experimental investigation of shear connector behaviour in composite beams with metal decking

  • Qureshi, Jawed;Lam, Dennis
    • Steel and Composite Structures
    • /
    • 제35권4호
    • /
    • pp.475-494
    • /
    • 2020
  • Presented are experimental results from 24 full-scale push test specimens to study the behaviour of composite beams with trapezoidal profiled sheeting laid transverse to the beam axis. The tests use a single-sided horizontal push test setup and are divided into two series. First series contained shear loading only and the second had normal load besides shear load. Four parameters are studied: the effect of wire mesh position and number of its layers, placing a reinforcing bar at the bottom flange of the deck, normal load and its position, and shear stud layout. The results indicate that positioning mesh on top of the deck flange or 30 mm from top of the concrete slab does not affect the stud's strength and ductility. Thus, existing industry practice of locating the mesh at a nominal cover from top of the concrete slab and Eurocode 4 requirement of placing mesh 30 mm below the stud's head are both acceptable. Double mesh layer resulted in 17% increase in stud strength for push tests with single stud per rib. Placing a T16 bar at the bottom of the deck rib did not affect shear stud behaviour. The normal load resulted in 40% and 23% increase in stud strength for single and double studs per rib. Use of studs only in the middle three ribs out of five increased the strength by 23% compared to the layout with studs in first four ribs. Eurocode 4 and Johnson and Yuan equations predicted well the stud strength for single stud/rib tests without normal load, with estimations within 10% of the characteristic experimental load. These equations highly under-estimated the stud capacity, by about 40-50%, for tests with normal load. AISC 360-16 generally over-estimated the stud capacity, except for single stud/rib push tests with normal load. Nellinger equations precisely predicted the stud resistance for push tests with normal load, with ratio of experimental over predicted load as 0.99 and coefficient of variation of about 8%. But, Nellinger method over-estimated the stud capacity by about 20% in push tests with single studs without normal load.

비내진 상세를 가진 10층 철근 콘크리트 조적채움 골조의 일방향 가력 실험 (Push-Over Test of A 10-Story Reinforced Concrete Masonry Infilled Frame with Nonseismic Details)

  • 이한선;김정우;김상호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.513-518
    • /
    • 1999
  • The objective of this experiment is to observe the elastic and inelastic behaviors of high-rise reinforced concrete frame with infilled masonry. To do this a building frame designed according to Korean seismic code and detailed in the Korean conventional manner was selected. An 1:12 scale plane masonry-infilled frame model was manufactured according to similitude law. Push-over test were performed under the roof displacement control. To simulate the earthquake effect, the lateral force distribution was maintained to be an inversed triangular by using whiffle tree. From the tests, story displacements, lateral story forces, local plastic rotations and the relations between inter-story drift versus story shear are obtained. Based on the test results, conclusions on the characteristics of the elastic and inelastic behaviors of a high-rise reinforced concrete frame with infilled masonry are drawn.

  • PDF

The push-out bond strength of BIOfactor mineral trioxide aggregate, a novel root repair material

  • Akbulut, Makbule Bilge;Bozkurt, Durmus Alperen;Terlemez, Arslan;Akman, Melek
    • Restorative Dentistry and Endodontics
    • /
    • 제44권1호
    • /
    • pp.5.1-5.9
    • /
    • 2019
  • Objectives: The aim of this in vitro study was to evaluate the push-out bond strength of a novel calcium silicate-based root repair material-BIOfactor MTA to root canal dentin in comparison with white MTA-Angelus (Angelus) and Biodentine (Septodont). Materials and Methods: The coronal parts of 12 central incisors were removed and the roots were embedded in acrylic resin blocks. Midroot dentin of each sample was horizontally sectioned into 1.1 mm slices and 3 slices were obtained from each root. Three canal-like standardized holes having 1 mm in diameter were created parallel to the root canal on each dentin slice with a diamond bur. The holes were filled with MTA-Angelus, Biodentine, or BIOfactor MTA. Wet gauze was placed over the specimens and samples were stored in an incubator at $37^{\circ}C$ for 7 days to allow complete setting. Then samples were subjected to the push-out test method using a universal test machine with the loading speed of 1 mm/min. Data was statistically analyzed using Friedman test and post hoc Wilcoxon signed rank test with Bonferroni correction. Results: There were no significant differences among the push-out bond strength values of MTA-Angelus, Biodentine, and BIOfactor MTA (p > 0.017). Most of the specimens exhibited cohesive failure in all groups, with the highest rate found in Biodentine group. Conclusions: Based on the results of this study, MTA-Angelus, Biodentine, and BIOfactor MTA showed similar resistances to the push-out testing.

Unified equivalent frame method for flat plate slab structures under combined gravity and lateral loads - Part 2: verification

  • Choi, Seung-Ho;Lee, Deuck Hang;Oh, Jae-Yuel;Kim, Kang Su;Lee, Jae-Yeon;Shin, Myoungsu
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.735-751
    • /
    • 2014
  • In the previous paper, authors proposed the unified equivalent frame method (UEFM) for the lateral behavior analysis of the flat plate structure subjected to the combined gravity and lateral loads, in which the rotations of torsional members were distributed to the equivalent column and the equivalent slab according to the relative ratio of gravity and lateral loads. In this paper, the lateral behavior of the multi-span flat plate structures under various levels of combined gravity and lateral loads were analyzed by the proposed UEFM, which were compared with test results as well as those estimated by existing models. In addition, to consider the stiffness degradation of the flat plate system after cracking, the stiffness reduction factors for torsional members were derived from the test results of the interior and exterior slab-column connection specimens, based on which the simplified nonlinear push-over analysis method for flat plate structures was proposed. The simplified nonlinear analysis method provided good agreements with test results and is considered to be very useful for the practical design of the flat plate structures under the combined gravity and lateral loads.

스터드커넥터의 내화성능에 관한 연구 (Study on Fire Performance of Stud Connectors)

  • 김성배;한상훈;최승관
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.59-66
    • /
    • 2009
  • 본 연구는 합성구조에 사용되는 스터드커넥터의 화재시 성능에 대한 연구이다. 스터드커넥터는 전단연결재로 가장 폭넓게 사용되고 있으며, 콘크리트와 강재를 일체화시켜 합성 성능을 확보한다. 스터드커넥터에 대한 상세 내화성능은 아직 명확한 자료가 없으며, 향후 성능설계에서 무피복 합성보 등에 대한 설계 자료로 요구 된다. 본 실험의 스터드커넥터 성능시험은 푸시 아웃 실험을 변형하여 특수 전기로와 결합 ISO 표준온도곡선을 기본으로 거동 성능실험을 수행하였으며, 화재 조건의 파괴 형상을 기반으로 성능 분석 방법을 제안하였다.

FE Analysis for 1/3-scaled RC Building Structure under Biaxial Earthquake Loading

  • Lee, Joo-Beom;Rhee, In-Kyu
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.567-568
    • /
    • 2009
  • The CAMUS 2000-1 experimental program were performed in France to investigate of the 1/3-scaled reinforced concrete bearing walls behavior on the shaking table under biaxial earthquake loading. The nonlinear 3D finite element analysis of push over test and linear dynamic analysis under biaxial earthquake loading are investigated with the concrete damaged plasticity model using ABAQUS.

  • PDF

The effect of different adhesive system applications on push-out bond strengths of glass fiber posts

  • Kivanc, Bagdagul Helvacioglu;Arisu, Hacer Deniz;Uctasli, Mine Betul;Okay, Tufan Can
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.305-311
    • /
    • 2013
  • PURPOSE. Over the past years, the adhesion of fiber posts luted with simplified adhesive systems has been a matter of great interest. The aim of this study was to assess the post retentive potential of a self-adhesive resin cement using different adhesive systems to compare the push-out bond strengths of fiber posts. MATERIALS AND METHODS. The post spaces of 56 mandibular premolar roots were prepared and divided into 4 experimental groups and further divided into 2 subgroups according to testing time (n=7). The fiber posts (Rely X Fiber Post) were luted with a self-adhesive resin cement (RelyX Unicem) and one of the following adhesive systems: no adhesive, a total-etch adhesive resin (Single Bond), a two-step self-etch adhesive resin (Clearfil SE Bond) and a one-step self-etch adhesive resin (Clearfil S3 Bond). Each root was cut horizontally, and 1.5 mm thick six root segments were prepared. Push-out tests were performed after one week or three months (0.5 mm/min). Statistical analysis were performed with three-way ANOVA (${\alpha}$=.05). RESULTS. Cervical root segments showed higher bond strength values than middle segments. Adhesive application increased the bond strength. For one week group, the total-etch adhesive resin Single Bond showed higher bond strength than the self-adhesive resin cement RelyX Unicem applied without adhesive resin at middle region. For 3 months group, the two-step self-etch adhesive resin Clearfil SE Bond showed the highest bond strength for both regions. Regarding the time considered, Clearfil SE Bond 3 months group showed higher bond strength values than one week group. CONCLUSION. Using the adhesive resins in combination with the self-adhesive resin cement improves the bond strengths. The bond strength values of two-step self-etch adhesive resin Clearfil SE Bond improved as time passes.

접합부와 보의 상대강성을 고려한 중층 철골 모멘트 골조의 내진해석 (Seismic Analysis of Mid Rise Steel Moment Resisting Frames with Relative Stiffness of Connections and Beams)

  • 하성환;강철규;한홍수;한권규;최병정
    • 한국강구조학회 논문집
    • /
    • 제23권5호
    • /
    • pp.595-606
    • /
    • 2011
  • 본 연구는 기둥-보 접합부의 강성에 따른 철골 모멘트 골조의 동적특성의 차이를 파악하는데 목적이 있다. 6층의 철골 모멘트 골조를 설계하였으며, 접합부는 DWA (Double Web-Angle Connection), TSW (Top-and Seat-Angle Connection with Double Web-Angle), FEMA(SAC-Test Summary No.28, Specimen ID : UCSD-6) 접합부를 사용하였고, 완전강접합부의 동적거동특성과 상호 비교 검토하였다. 반강접 접합부의 회전강성은 Chen 과 Kishi 에 의해 제안된 3매개변수파워모델을 사용하여 구하였다. 접합부의 회전 강성을 보의 강성으로 나누어 상대강성으로 정의하여 사용하였다. 모든 골조에 대하여 비선형 정적해석(push over analysis), 반복하중 해석 및 시간이력해석을 수행하였다. 각 접합부의 강성에 따른 내진거동은 층간변위, 소성힌지 및 이력 에너지 분배의 항목별로 비교 분석하였다.

적재설비 안정성 확보를 위한 FE 해석 기반의 연결부 모델 개발 (Development of Connection Model based on FE Analysis to Ensure Stability of Steel Storage Racks)

  • 허광희;김충길;유달리;전종수;이진옥
    • 대한토목학회논문집
    • /
    • 제38권2호
    • /
    • pp.349-356
    • /
    • 2018
  • 본 논문은 국내에서 연구가 미진한 적재설비의 지진 취약도 평가에 적용할 수 있는 FE 해석 기반의 연결부 모델을 개발하는데 목적이 있다. 이러한 목표를 달성하기 위하여, 적재설비 거동을 파악하기 위한 진동대 실험과 Modal Test, 그리고 구성 부재를 대상으로 한 다양한 부재실험(8가지 Push-over Test)을 진행하였다. 실험결과를 바탕으로 지진취약도 평가에 적용하기 위한 적재설비의 연결부 모델을 개발하기 위하여, NX-Nastran 프로그램을 활용하여 연결부의 상세 모델링을 진행하였다. 특히, 단순 걸쇠 방식으로 연결되는 기둥 부재와 보 부재의 연결을 모사하기 위하여 면대면 표면접촉 요소와 스프링 요소를 적용하였으며, 스프링 요소의 모델은 ARX (Auto Regressive eXogenous) 기반의 수학적 모델을 개발하여 적용하였다. FE 모델 기반의 simulation 결과는 부재 실험 결과와 비교하였을 때, 상호 오차율 8% 미만의 우수한 신뢰도를 보여주었다. 결과적으로 연구에서 개발한 FE해석 기반의 연결부 모델은 적재설비의 지진 취약도 평가를 위한 해석 모델에 활용될 수 있음을 확인하였다.