• Title/Summary/Keyword: radial arterial

Search Result 90, Processing Time 0.027 seconds

Sa-Am Acupuncture with Spleen Seung-gyuck induces an acute increase of radial pulse parameters related to arterial stiffness in healthy subjects: A comparative study of Jung-gyuck and Seung-gyuck

  • Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.35 no.2
    • /
    • pp.19-27
    • /
    • 2014
  • Objectives: To investigate the different effects of Sa-Am acupuncture with Spleen Jung-gyuck and Spleen Seung-gyuck on the radial pulse in healthy subjects. Methods: Sixty healthy volunteers (30 males and 30 females) participated in this study. The participants were randomly divided into three groups: control (C), Sa-Am acupuncture with Spleen Jung-gyuck (SP+) and Sa-Am acupuncture with Spleen Seung-gyuck (SP-). The radial pulse was measured using a multi-step tonometry system before, and 0, 30 and 60 minutes after acupuncture. Results: The heart rate adjusted radial augmentation index (RAI/HR) and high-tensioned pulse area (W area) significantly increased in the SP- group compared to the C and SP+ groups in males. The systolic pulse period (T4) increased significantly in the SP- group compared to the C and SP+ groups in females. The RAI/HR had positive correlations with W area and T4. Conclusion: The effects of Sa-Am acupuncture with Spleen Jung-gyuck and Spleen Seung-gyuck are different. Sa-Am acupuncture with Spleen Seung-gyuck induces acute increases of radial pulse parameters related to arterial stiffness in healthy subjects.

A New Experimental Method of Mechanical Analysis for Arterial Cross-Section Research (동맥 전단부의 역학적분석을 위한 새로운 실험적 방법)

  • 황민철;신정욱
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.149-156
    • /
    • 1995
  • This paper suggests a new experimental system and protocol of mechanical analysis for arterial cross-section research. So far, most methods of arterial studies have been focused on the deformation measurement in longitudinal and circumferential direction. The deformation in radial direction has been theoretically assumed by Poisson's ratio and/or the incompressibility of arterial wall. Also, the radial gradient of strains are neglected. In fact, the radial deformation and radial gradient of strains against blood pressure are important to be observed in the pathological point of view of artery. Proposed experimental system and protocol are to measure the deformation of cross-sectional artery. Also, this method enables to measure the deformation of anterior, posterior, and side site of cross-sectional area. It is meaningful to correlate the mechanically experimented data with pathological data of athroscIerotic artery.

  • PDF

A Comparative Study of Methods of Measurement of Peripheral Pulse Waveform

  • Kang, Hee-Jung;Lee, Yong-Heum;Kim, Kyung-Chul;Han, Chang-Ho
    • The Journal of Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.98-105
    • /
    • 2009
  • Objective: Increased aortic and carotid arterial augmentation index (AI) is associated with the risk of cardiovascular disease. The most widely used approach for determining central arterial AI is by calculating the aortic pressure waveform from radial arterial waveforms using a transfer function. But how the change of waveform by applied pressure and the pattern of the change rely on subject's characteristics has not been recognized. In this study, we use a new method for measuring radial waveform and observe the change of waveform and the deviation of radial AI in the same position by applied pressure. Method: Forty-six non-patient volunteers (31 men and 15 women, age range 21-58 years) were enrolled for this study. Informed consent in a form approved by the institutional review board was obtained in all subjects. Blood pressure was measured on the left upper arm using an oscillometric method, radial pressure waves were recorded with the use of an improved automated tonometry device. DMP-3000(DAEYOMEDI Co., Ltd. Ansan, Korea) has robotics mechanism to scan and trace automatically. For each subject, we performed the procedure 5 times for each applied pressure level. We could thus obtain 5 different radial pulse waveforms for the same person's same position at different applied pressures. All these processes were repeated twice for test reproducibility. Result: Aortic AI, peripheral AI and radial AI were higher in women than in men (P<0.01), radial AI strongly correlated with aortic AI, and radial AI was consistently approximately 39% higher than aortic AI. Relationship between representative radial AI of DMP-3000 and peripheral AI of SphygmoCor had strongly correlation. And there were three patterns in change of pulse waveform. Conclusion: In this study, it is revealed the new device was sufficient to measure how radial AI and radial waveform from the same person at the same time change under applied pressure and it had inverse-proportion to applied pressure.

  • PDF

Anomaly of the Radial Artery Encountered During the Excision of Wrist Ganglion: A Case Report (손목 결절종제거술 시 경험한 요골동맥 기형의 치험례)

  • Kim, Chul-Han;Song, Woo-Jin
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.105-108
    • /
    • 2011
  • Purpose: An extensive knowledge of the arterial anatomy of the upper extremity and its variations is indispensable to the hand surgeon. We report a patient with anomalous radial artery, superficial course of two radial arteries, encountered during the excision of volar wrist ganglion. Methods: The patient was a 53-year-old man who had a painful mass on the left volar wrist for 1 year. Under general anesthesia, a curved incision was made around the mass. With the skin flaps retracted, the dome of the cyst was identified. Particular care was taken to identify and protect the radial artery, which was intimately attached to the wall of the ganglion. Two radial arteries completely encircled the ganglion. The pedicle was traced to the volar joint capsule, radiocarpal ligament. The joint was open and the capsular attachments were excised. Results: The patient made an uneventful recovery. There were two arterial pulsations at the volar side of the wrist joint. Compressing this site revealed that the major arterial contributor to blood supply in the hand was the ulnar artery. At angioCT, an anomaly of the radial artery was found with a duplication. The pathway of this aberrant artery was superficial to the original radial artery. It changed its course subcutaneously at the level of the tendon of the brachioradialis muscle, and crossing the wrist lateral to the original radial artery and ending in the deep palmar arch. Conclusion: Authors experienced a case of bifurcating radial artery encountered during the excision of ganglion on the volar of the wrist. Because these duplicated radial arteries make strong contributions to the thumb and index finger as well as to the deep palmar arch, when they are present there may be probably less blood supply to the hand from the ulnar artery. If the radial artery is palpated superficially on the brachioradialis muscle, it is important to remember the kind of anomaly.

Detection of Radial Pulse Wave by Photoplethysmogram (광전용적맥파를 이용한 요골동맥 맥파 검출)

  • 정동근;김광년;연규선;최병철;서덕준
    • Journal of Life Science
    • /
    • v.13 no.1
    • /
    • pp.42-46
    • /
    • 2003
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes radial pulse waves recorded by photoplethysmogram with 940 nm wavelength infra red light. Radial pulse waves were varied according to the recording site. When recorded on the skin over radial artery, the radial pulse wave was inverted, comparing to the photoplethysmogram at fingertip. The mechanism of inverted pulse wave seemed to be caused by the change of the blood volume in the subcutaneous tissue between radial artery and the skin, which was reduced during systolic period and increased during diastolic period of the cardiac cycle. These results suggest that radial arterial wall may reflect infra red ray.

Early result of Coronary Artery Bypass Grafting Using the Internal Thoracic and the Radial Arteries (내흉동맥과 요골동맥을 이용한 관상동맥우회술의 조기 결과)

  • 나찬영;이영탁
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.891-896
    • /
    • 1999
  • Increasing interest in the use of arterial conduites is based on the better patency of the internal thoracic artery(ITA) than the saphenous vein graft and the hope that other arterial conuits will perform similarly over the long term. Material and Method: Between May 1997 and July 1998, 43 patients underwent coronary artery bypass grafting with ITA and the radial artery(RA). There were 28 men and 15 women with a mean age of 61.5 years(range, 35 to 78). In 43 patents, 30 bilateral ITA(including 7 diabetes mellitus, 5 more older 70 years), 8 bilateral ITA only, 2 left ITA and both RA, 11 left ITA and left RA and 22 both ITA and left RA were used. Result: There was 1 hospital mortality. Of the 42 patients alive, 39 patients are asymptomatic. Postoperative complications were postoperative bleeding in 1 patients, and low cardiac output syndrome in 3. Follow-up angiography was performed in 5 patients after the operation(mean 3 months), and all ITA & RA grafts showed excellent results. Conclusion: We conclude that complete arterial revascularization with internal thoracic artery and radial artery is technically feasiale with low mortality and morbidity, and but long term follow-up is needed.

  • PDF

Noninvasive Detection of Radial Pulse Wave by Fiber-Optic Transducer (광파이버 트랜스듀서에 의한 맥파의 무침습적 검출)

  • 박승환;정동명
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.229-236
    • /
    • 1989
  • This paper describes an idea of design and construction for a radial pulse wave detector, In acquiring arterial pulse signal noninvasively, a new combinational fiber-optic transducer was used which has a detecting part and a sensing part. The mechanism of detecting part is composed of special form of structure that can detect changing pulses in contact with skin, and transmits arterial wall movements to the sensing part. It consists of elastic reflector and optical fibers, which are arranged in a fiber pair. Then, the intensity of the reflected light will be proportional to the displacement changed by inclined reflector. Using this transducer, it expected to make a clinically useful tool for arterial pulse wave diagnosis, especially on the application of "MACK- CHIN" in the field of Korean traditional medicine, since : his transducer has a simple structure and has an easy and clear signal acquisition method.on method.

  • PDF

The Heart Rate Monitoring System using Inverted Photoplethysmography (반전 용적맥파 신호를 이용한 심박 모니터링 시스템)

  • Lee, Jun-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.105-111
    • /
    • 2012
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes implementation a photoplethysmography monitoring system that uses 780nm and 940nm length infrared light in radial artery. That system used combinations of 8 LEDs and 2 photoelectricities. When recorded on the skin over radial artery, the radial pulse wave was inverted. The mechanism of inverted pulse wave skin, which was reduced during systolic period and increase during diastolic period of the cardiac cycle. Through this system, we discovered optimal environments and combinations of sensors in both penetration type and reflection type. These results suggest that radial arterial wall way reflect infrared ray.

Comparison of Radial Artery and Saphenous Vein Composite Y Grafts during Off-pump Coronary Artery Bypass

  • Wi, Jin-Hong;Joo, Hyun-Chel;Youn, Young-Nam;Song, Suk-Won;Kim, Tae Hoon;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.265-273
    • /
    • 2013
  • Background: The safety and efficacy of arterial composite grafts for total arterial revascularization have been demonstrated. The saphenous vein (SV) is a widely used graft because of its accessibility, sufficient length, and ease of manipulation. Our aim was to compare mid-term outcomes of saphenous vein Y-grafts with radial artery Y-grafts joined by anastomosis to the left internal thoracic artery. Materials and Methods: Records of off-pump coronary artery bypass grafting with composite Y-grafts based on the left internal thoracic artery technique in 552 patients were analyzed retrospectively. After propensity score matching, 79 radial arterial (RA) composite grafts (RA group) and 79 saphenous vein composite grafts (SV group) were compared. The duration of mean follow-up was $24.6{\pm}14.6$ months (range, 1 to 55 months). Results: There were no differences in surgical mortality, all-cause mortality, or morbidity among the groups. Rates of 4-year survival were 91.7% and 96.3% in the RA and SV groups, respectively (p=0.519). The coronary reintervention-free survival rate and freedom from major adverse cardiovascular or cerebrovascular events were similar in the two groups (p=0.685, p=0.564). Conclusion: Construction of composite Y-grafts using the radial artery or saphenous vein showed similar mid-term results. Long-term follow-up and randomized trials will be needed to confirm our present conclusions.

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF