UWB Automobile Short Range Radar Receivers Performance In a Log-Normal Clutter Background (Log-Normal Clutter 환경에서 차량용 UWB 단거리 레이더 수신기의 성능분석)

  • Kumaravelu, Nandeeshkumar;Ko, Seok-Jun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.9
    • /
    • pp.59-64
    • /
    • 2011
  • Ultra wideband radars attract considerable attention as a short range automotive radar because of its high range resolution. Radar signal reflected from a target often contains unwanted echoes called as clutter, so the detection of target is difficult due to clutter echoes. Therefore, it is important to investigate the radar detector for better detecting from the reflected signals. In this paper, the optimal detector is obtained for various mean and variance value in log-normal clutter environment. The types of non-coherent detectors used are square law detector, linear detector, and logarithmic detector. The performances of detectors are compared in log normal clutter environment and the suitable detector is determined for automotive short range radar application.

Performance Analysis of Detector in Automobile Pulse Radar with Considering Interference (차량용 펄스 레이더에서 간섭영향에 대한 검출기의 성능 분석)

  • Lee, Jonghun;Ko, Seokjun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2019
  • In this paper, we consider interferences from other automobile pulse radars using same frequency spectrum. In order to eliminate the interference, we propose the PN code modulation method. This method uses the cross-correlation between PN codes with different seed. The ROC performance is used for comparing the proposed detector to conventional method. And the proposed detector can decide the present or absent of targets and measure the range of the targets by using memory buffer of range gate. Especially, we use false alarm probability for all range gates. That is the false alarm if in any one range gate the false alarm occurs. From the simulation result, we can see that the proposed detector with using PN code is not influenced by interferences.

Design of Wide-Range radiation measurement system using GM Tube and NaI(TI) Detector (GM Tube 및 NaI(TI) 검출기를 사용한 Wide-Range 방사선 측정 시스템의 설계)

  • Ra, Seung-Tak;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.2
    • /
    • pp.146-149
    • /
    • 2017
  • In this paper, we propose a wide-range radiation measurement system using GM Tube and NaI(TI) detector. The proposed system is designed as a small module optimized to control and count the detector signal of NaI(Tl) Detector and GM Tube. The radiation dose is measured in a wide-range 0.1uSv/h to 10mSv/h in conjunction with two detectors, and two detectors operate simultaneously at 10uSv/h to 100uSv/h, where the measurement interval overlaps. The radiation dose was selected using a wide-range radiation measurement algorithm that controls the on/off function of the detector in the appropriate interval for the overlapped radiation measurable interval. In order to evaluate the performance of the proposed system, it has been confirmed that the measurement uncertainty of each section is measured as ${\pm}7.5%$ and it operates normally under ${\pm}15%$ of the international standard.

Design of a 6-bit 500MS/s CMOS A/D Converter with Comparator-based Input Voltage Range Detection Circuit

  • Dae, Si;Yoon, Kwang Sub
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.706-711
    • /
    • 2014
  • A low power 6-bit flash ADC that uses an input voltage range detection algorithm is described. An input voltage level detector circuit has been designed to overcome the disadvantages of the flash ADC which consume most of the dynamic power dissipation due to comparators array. In this work, four digital input voltage range detectors are employed and each input voltage range detector generates the specific clock signal only if the input voltage falls between two adjacent reference voltages applied to the detector. The specific clock signal generated by the detector is applied to turn the corresponding latched comparators on and the rest of the comparators off. This ADC consumes 68.82 mW with a single power supply of 1.2V and achieves 4.3 effective number of bits for input frequency up to 1 MHz at 500 MS/s. Therefore it results in 4.6 pJ/step of Figure of Merit (FoM). The chip is fabricated in 0.13-um CMOS process.

Pull-in Characteristics of Delay Switching Phase-Locked Loop (Delay Switching PLL의 Pull-in 특성)

  • 장병화;김재균
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.5
    • /
    • pp.13-18
    • /
    • 1978
  • A delay switching PLL (DSPLL) is proposed for improvement of the frequency acquisition Performance (pull-in range) while keeping a narrow bandwidth LPF. It has, between the phase detector and the LPF, just a simple RC delay circuit, a switch and another phase detector controlling the switching time. For the common second order PLL, the pull-in capability of the DSPLL is analyzed approximately, without considering additive white noise effect, and verified experimentally. It is shown that the delay switching extends the pull-in range significantly, as much as a half of lock-range. At the phase tracking mode, the delay switching does not function, to make the DSPLL be a normal PLL.

  • PDF

Design and Implementation of Broadband Power Detector for Six-port Direct Conversion Receiver (Six-port 직접 변환 수신을 위한 광대역 Power detector 설계 제작)

  • Lee, Yong-Ju;Kim, Yeong-Wan;Park, Dong-Cheol
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • The broadband power detector for power amplitude envelope detection of the direct-conversion Six-port output signal was designed and implemented in this paper. The power detector should be linearly operated to produce the linear amplitude and phase signal for input RF signals in required broadband frequency range. The power detector should be designed under conditions of matching circuit with low VSWR, which protect unbalanced phase signal from reflection signal due to mismatch between the output port of a six-port and the input port of a power detector. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with multiple LC matching circuits and isolator, respectively, were analyzed in viewpoints of the utilization as a power detector of direct conversion Six-port. The dynamic range of designed power detectors were also measured and rvaluated as a power detector of Six-port circuit.

  • PDF

Design of RF Power Detector Module with Switch for W-CDMA Optic Repeater (스위치를 이용한 W-CDMA 광중계기용 RF 전력 검출기 모듈의 설계)

  • Lee, Yun-Bok;Cho, Jung-Yong;Shin, Kyung-Sub;Lee, Yong-An;Lee, Hong-Min
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.389-393
    • /
    • 2003
  • This paper describes the design of enhanced TSSI RF Power Detector which has wide dynamic range using switch and Log amp. This Power Detector consists of low and high gain loops, and they adaptively switched by output DC voltage which is proportioned to input power level. Because Power Detector needs to separate the channel, so architecture is heterodyne system having 70MHz intermediate frequency. This proposed RF Power Detector is settle to the satisfaction of Closed loop power control system for W-CDMA optic repeater, and the obtained dynamic range cover the higher than 50dB.

  • PDF

UV/IR flame detector using Microprocessor (마이크로프로세서를 사용한 UV/IR 불곶 감지기)

  • 박성진;임병현;임종연;김명원;윤길호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.215-218
    • /
    • 2001
  • A flame detector responds either to radiant energy visible to the human eye or outside the range of human vision. Such a detector is sensitive to glowing embers, coals, or flames which radiate energy of sufficient intensity and spectral quality to actuate the alarm. An infra-red detectors can respond to the total IR component of the flame alone or in combination with flame flicker in the frequency range of 5 to 30 Hz. A major problem in the use of infrared detectors receiving total IR radiation is the possible interference of solar radiation in the infrared region. When detectors are located in places shielded from the sun, such as vaults. filtering or shielding the unit from the sun's rays is unnecessary. In this study, we proposed method for redue a false alarm with using filtering & sensor technology for distinguish of causes of raise a false alarm and pure flame.

  • PDF

Analog Delay Locked Loop with Wide Locking Range

  • Yoo, Changsik
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.3
    • /
    • pp.193-196
    • /
    • 2001
  • For wide locking range, an analog delay locked loop (DLL) was designed with the selective phase inversion scheme and the variable number of delay elements. The number of delay elements was determined adaptively depending on the clock cycle time. During the analog fine locking stage, a self-initializing 3-state phase detector was used to avoid the initial state problem associated with the conventional 3-state phase detector. With these schemes, the locking range of analog DLL was increased by four times compared to the conventional scheme according to the simulation results.

  • PDF

Precise Measurement of Beam Energy and Range with TOF and Counter Telescope System

  • Nanbu, Shuya;Kanai, Tatsuaki;Kohno, Toshiyuki;Ohno, Yumiko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.225-227
    • /
    • 2002
  • In order to improve the accuracy of charged-particle radiation therapy, the beam energy was measured precisely using a TOF-system, and the range using a counter telescope system. A Si detector and a Ge detector were used to estimate the range straggling as a $\Delta$E and an E detector, respectively, because they have good energy resolution and the output pulse heights don't depend on the atomic number of detected particles. The results were compared with the theoretical values by a calculation code.

  • PDF