• 제목/요약/키워드: recharge

검색결과 495건 처리시간 0.028초

NRCS-CN방법과 기저유출 분리법을 이용한 지하수함양률 산정 (Estiamtion of Groundwater Recharge Rate Using the NRCS-CN and the Baseflow Separation Methods)

  • 배상근;김용호
    • 한국환경과학회지
    • /
    • 제15권3호
    • /
    • pp.253-260
    • /
    • 2006
  • Groundwater recharge from precipitation is affected by the infiltration from ground surface and the movement of soil water. Groundwater recharge is directly related to the groundwater amount and flow in aquifers, and baseflow to rivers. Determining groundwater recharge rate for a given watershed is a prerequisite to estimate sustainable groundwater resources. The estimation of groundwater recharge rate were carried out for three subwatersheds in the Wicheon watershed and two subwatersheds in the Pyungchang River basin and for the period 1990-2000, using the NRCS-CN method and the baseflow separation method. The recharge rate estimates were compared to each other. The result of estimation by the NRCS-CN method shows the average annual recharge rate 15.4-17.0% in the Wicheon watershed and 26.4-26.8% in the Pyungchang River basin. The average annual recharge rates calculated by the baseflow separation method ranged 15.1-21.1% in the W icheon watershed, and 25.2-33.4% in the Pyungchang River basin. The average annual recharge rates calculated by the NRCS-CN method is less variable than the baseflow separation method. However, the average annual recharge rates obtained from the two methods are not very different, except NO. 6 subwatershed in Pyungchang River basin.

Evaluation of Groundwater Flow Analysis Using Rainfall-Recharge Estimation Methods

  • Choi, Yun-Yeong;Sim, Chang-Seok;Bae, Sang-Keun
    • 한국환경과학회지
    • /
    • 제16권5호
    • /
    • pp.561-569
    • /
    • 2007
  • This study used SCS-CN method to estimate the real recharge of the study area which is one of the most reasonable techniques to estimate groundwater recharge when there is no available runoff data in a watershed. From the results of tile real recharge analysis for the study area using SCS-CN method, it was analyzed that the year 1994 when the drought was severe shotted the lowest recharge of 106.3mm with recharge rate of 12.4%, and the highest recharge of 285.6mm with recharge rate of 21.8% occurred in 1990. Yearly average recharge of 213.2mm was obtained, and tile average recharge rate was 16.9%/year. KOG-FLOW model which has powerful post process functions consists of setting environments for input parameters in Korean language, and help function is added to each input data. Detailed information for each parameter is displayed when the icon is placed on the input parameters, and geologic boundaries or initial head data for each layer can be set easily on work sheet. The relative errors (R. E.) for each model's observed values and calculated values are $0.156{\sim}0.432$ in case of KOG-FLOW, and $0.451{\sim}1.175$ in case of WINFLOW, therefore it is known that KOG-FLOW model developed in this study produced results compared to observed head values.

ESTIMATION OF NET GROUND WATER RECHARGE IN LARGE AQUIFER SYSTEMS BY GENETIC ALGORITHM: A CASE STUDY

  • K. Lakshmi Prasad;A. K. Rastogi
    • Water Engineering Research
    • /
    • 제2권3호
    • /
    • pp.161-169
    • /
    • 2001
  • Present study deals with the development of a numerical model for the estimation of net annual recharge by coupling the Galerkin's finite element flow simulationl model with the Gauss-Newton-Marquardt optimization technique. The developed coupled numerical model is applied for estimating net annual recharge for Mahi Right Bank Canal (MRBC) project the norms of Groundwater Resources Estimation committee (1984, 1997) and Indian Agricultural research Institute(1983). It is observed that the estimated net recharge by inverse modeling is closer to the net recharge estimated using the water balance approach. Further it is observed that the computed head distribution from the estimated recharge agree closely with the observed head distribution. The study concludes that the developed model for inverse modeling can be successfully applied to large groundwater system involving regional aquifers where reliable recharge estimation always requires considerable time and financial resources.

  • PDF

Estimating groundwater recharge from time series measurements of subsurface temperature

  • Koo, Min-Ho;Kim, Yongje
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.213-216
    • /
    • 2003
  • Efforts for better understanding of the interaction between groundwater recharge and thermal regime of the subsurface medium is gaining momentum for its diverse applications in water resources. A numerical model is developed to simulate temperature variations of the subsurface under time varying groundwater recharge. The model utilizes MacCormack scheme for finite difference approximation of the partial differential equation describing the conductive and advective heat transport. For the estimation of recharge rate, optimization of the model is realized by searching for the unknown parameters which minimize the root-mean-square error between simulated and measured temperatures. Simulation results for 22-year time series data of temperature measurements reveal that the proposed model can accurately simulate subsurface temperature variations resulting from the redistribution of the heat due to the movement of water and it can also estimate temporal variations of recharge. Seasonal variations of recharge and a linear relationship between precipitation and recharge are clearly reflected in the simulated results.

  • PDF

A numerical analysis of precipitation recharge in the region of monsoon climates using an infiltration model

  • Koo, Min-Ho;Kim, Yongje
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.163-167
    • /
    • 2003
  • Based on the transient finite difference solution of Richards' equation, an infiltration model is developed to analyze temporal variation of precipitation recharge in the region of monsoon climates. Simulation results obtained by using time series data of 20-year daily precipitation and pan evaporation indicate that a linear relationship between the annual precipitation and the annual recharge holds for the soils under the monsoon climates with varying degrees of the correlation coefficient depending on the soil types. A sensitivity analysis reveals that the water table depth has little effects on the recharge for the sandy soil, whereas, for the loamy and silty soils, rise of the water table at shallow depths causes increase of evaporation by approximately 100㎜/yr and a corresponding decrease in recharge. A series of simulations for two-layered soils illustrate that the amount of recharge is dominantly determined by the soil properties of the upper layer, although the temporal variation of recharge is affected by both layers.

  • PDF

제주도 한천유역 지하수 모델개발을 통한 인공함양 평가 (Modeling Artificial Groundwater Recharge in the Hancheon Drainage Area, Jeju island, Korea)

  • 오세형;김용철;구민호
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권6호
    • /
    • pp.34-45
    • /
    • 2011
  • For the Hancheon drainage area in Jeju island, a groundwater flow model using Visual MODFLOW was developed to simulate artificial recharge through injection wells installed in the Hancheon reservoir. The model was used to analyze changes of the groundwater level and the water budget due to the artificial recharge. The model assumed that $2{\times}10^6m^3$ of storm water would recharge annually through the injection wells during the rainy season. The transient simulation results showed that the water level rose by 39.6 m at the nearest monitoring well and by 0.26 m at the well located 7 km downstream from the injection wells demonstrating a large extent of the affected area by the artificial recharge. It also shown that, at the time when the recharge ended in the 5th year, the water level increased by 81 m at the artificial reservoir and the radius of influence was about 2.1 km downstream toward the coast. The residence time of recharged groundwater was estimated to be no less than 5 years. The model also illustrated that 15 years of artificial recharge could increase the average linear velocity of groundwater up to 1540 m/yr, which showed 100 m/yr higher than before. Increase of groundwater storage due to artificial recharge was calculated to be $2.4{\times}10^6$ and $4.3{\times}10^6m^3$ at the end of the 5th and 10th years of artificial recharge, respectively. The rate of storage increase was gradually diminished afterwards, and storage increase of $5.0{\times}10^6m^3$ was retained after 15 years of artificial recharge. Conclusively, the artificial recharge system could augment $5.0{\times}10^6m^3$ of additional groundwater resources in the Hancheon area.

강수량 변화가 지하수함양량에 미치는 영향 (The Effect of Precipitation Change to the Groundwater Recharge)

  • 이승현;배상근
    • 한국습지학회지
    • /
    • 제13권3호
    • /
    • pp.377-384
    • /
    • 2011
  • 강수량변화가 도시 및 해안지역의 지하수함양량에 미치는 영향을 파악하기 위하여 부산광역시 수영구를 포함하는 광역 지하수유역에 강수량자료를 변화시켜 지하수함양량을 산정하고 강수량증감에 따른 지하수함양량의 변화특성을 분석하였다. 그 결과, 강수량 증감에 따라 지하수함양량의 증감량은 차이가 있으나 강수량과 지하수함양량의 변화 양상은 동일한 경향을 나타내었다. 강수량의 변화에 대한 지하수함양률의 변화폭이 최근으로 올수록 적어지는 경향을 나타내었다. 또한 연도가 증가함에 따라 지하수함양률이 감소하는 추세를 나타내었다. 강수량 변화 시의 지하수함양량의 전체 평균 변화율은 강수량이 10 % 증가 시에는 2.23 %, 10 % 감소 시에는 2.20 %, 20 % 증가 시에는 4.39 %, 20 % 감소 시에는 4.36 %로 강수의 변화율에 비하여 지하수함양량은 적은 변화율을 보였다. 이들 결과로부터 강수량의 변화율에 비하여 지하수함양률의 변화가 크지 않음을 알 수 있었다. 따라서 도시지역에서 강수량이 변화할 시에는 지하수함양량의 변화율이 이에 미치지 못함으로 직접유출에 미치는 영향이 그 양만큼 커지게 되어 도시홍수의 발생가능성이 지속적으로 증가하게 됨을 알 수 있었다.

소유역의 강수에 의한 지하수 함양량 산정 (Estimation of Groundwater Recharge from Precipitation in a Small Basin)

  • 배상근;이승현
    • 한국수자원학회논문집
    • /
    • 제37권5호
    • /
    • pp.397-406
    • /
    • 2004
  • 어떤 특정 지역의 지하수 개발량을 적적히 파악하기 위해서는 지하수함양량의 산정이 필요하다. 경상북도에 위치한 위천 유역내의 소유역에 대하여 지하수 함양량을 산정하였다. 기저유출분리법과 SCS-CN방법을 이용하여 갈수년과 풍수년이 존재하는 1992년∼1997년간의 년 평균 지하수 함양량을 추정하였다. 기저유출분리법을 이용하여 추정한 결과, 연평균 지하수 함양률이 11.9%∼18.7%로 변화하였으며 계산기간 중의 년 평균 강수에 의한 지하수 함양량은 141.6mm로 지하수함양률은 14.5%이었다. SCS-CN방법을 이용하여 추정한 결과, 연평균 지하수 함양균이 7.9%∼20.9%로 변화하였으며 계산기간 중의 년 평균 강수에 의한 피하수 함양량은 147.4mm 로 지하수 함양률은 15.1%이었다. 두 방법으로 산정한 갈수년과 풍수년이 존재하는 장기간 동안의 년 평균 강수에 의한 지하수 함양량은 지하수 개발에 유용하게 사용할 수 있음을 나타낸다.

Minimum Entropy Deconvolution을 이용한 지하수 상대 재충진양의 시계열 추정법

  • 김태희;이강근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.574-578
    • /
    • 2003
  • There are so many methods to estimate the groundwater recharge. These methods can be categorized into four groups. First groupis related to the water balance analysis, second group is concerned with baseflow/springflow recession, and third group is interested in some types of tracers; environmental tracers and/or temperature profile. The limitation of these types of methods is that the estimated results of recharge are presented in the form of an average over some time period. Forth group has a little different approach. They use the time series data of hydraulic head and specific yield evaluated from field test, and the results of estimation are described in the sequential form. But their approach has a serious problem. The estimated results in forth typeof methods are generally underestimated because they cannot consider the discharge phase of water table fluctuation coupled with the recharge phase. Ketchum el. at. (2000) proposed calibrated method, considering recharge- and discharge-coupled water table fluctuation. But the dischargeis considered just as the areal average with discharge rate. On the other hand, there are many methods to estimate the source wavelet with observed data set in geophysics/signal processing and geophysical methods are rarely applied to the estimation of groundwater recharge. The purpose this study is the evaluation of the applicability of one of the geophysical method in the estimation of sequential recharge rate. The applied geophysical method is called minimum entropy deconvolution (MED). For this purpose, numerical modeling with linearized Boussinesq equation was applied. Using the synthesized hydraulic head through the numerical modeling, the relative sequenceof recharge is calculated inversely. Estimated results are very concordant with the applied recharge sequence. Cross-correlations between applied recharge sequence and the estimated results are above 0.985 in all study cases. Through the numerical test, the availability of MED in the estimation of the recharge sequence to groundwater was investigated

  • PDF

지리정보시스템을 이용한 우리나라 인공함양 개발 유망지역 분석 (Site Prioritization for Artificial Recharge in Korea using GIS Mapping)

  • 서정아;김용철;김진삼;김용제
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제16권6호
    • /
    • pp.66-78
    • /
    • 2011
  • It is getting difficult to manage water resources in South Korea because more than half of annual precipitation is concentrated in the summer season and its intensity is increasing due to global warming and climate change. Artificial recharge schemes such as well recharge of surface water and roof-top rainwater harvesting can be a useful method to manage water resources in Korea. In this study, potential artificial recharge site is evaluated using geographic information system with hydrogeological and social factors. The hydrogeological factors include annual precipitation, geological classification based on geological map, specific capacity and depth to water level of national groundwater monitoring wells. These factors were selected to evaluate potential artificial recharge site because annual precipitation is closely related to source water availability for artificial recharge, geological features and specific capacity are related to injection capacity and depth to water is related to storage capacity of the subsurface medium. In addition to those hydrogeological factors, social aspect was taken into consideration by selecting the areas that is not serviced by national water works and have been suffered from drought. These factors are graded into five rates and integrated together in the GIS system resulting in spatial distribution of artificial recharge potential. Cheongsong, Yeongdeok in Gyeongsangbuk-do and Hadong in Gyeongsangnam-do, and Suncheon in Jeollanam-do were proven as favorable areas for applying artificial recharge schemes. Although the potential map for artificial recharge in South Korea developed in this study need to be improved by using other scientific factors such as evaporation and topographical features, and other social factors such as water-curtain cultivation area, hot spring resorts and industrial area where groundwater level is severely lowered, it can be used in a rough site-selection, preliminary and/or feasibility study for artificial recharge.