• Title/Summary/Keyword: recharge

Search Result 495, Processing Time 0.021 seconds

Estiamtion of Groundwater Recharge Rate Using the NRCS-CN and the Baseflow Separation Methods (NRCS-CN방법과 기저유출 분리법을 이용한 지하수함양률 산정)

  • Bae Sang-Keun;Kim Yong-Ho
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.253-260
    • /
    • 2006
  • Groundwater recharge from precipitation is affected by the infiltration from ground surface and the movement of soil water. Groundwater recharge is directly related to the groundwater amount and flow in aquifers, and baseflow to rivers. Determining groundwater recharge rate for a given watershed is a prerequisite to estimate sustainable groundwater resources. The estimation of groundwater recharge rate were carried out for three subwatersheds in the Wicheon watershed and two subwatersheds in the Pyungchang River basin and for the period 1990-2000, using the NRCS-CN method and the baseflow separation method. The recharge rate estimates were compared to each other. The result of estimation by the NRCS-CN method shows the average annual recharge rate 15.4-17.0% in the Wicheon watershed and 26.4-26.8% in the Pyungchang River basin. The average annual recharge rates calculated by the baseflow separation method ranged 15.1-21.1% in the W icheon watershed, and 25.2-33.4% in the Pyungchang River basin. The average annual recharge rates calculated by the NRCS-CN method is less variable than the baseflow separation method. However, the average annual recharge rates obtained from the two methods are not very different, except NO. 6 subwatershed in Pyungchang River basin.

Evaluation of Groundwater Flow Analysis Using Rainfall-Recharge Estimation Methods

  • Choi, Yun-Yeong;Sim, Chang-Seok;Bae, Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.16 no.5
    • /
    • pp.561-569
    • /
    • 2007
  • This study used SCS-CN method to estimate the real recharge of the study area which is one of the most reasonable techniques to estimate groundwater recharge when there is no available runoff data in a watershed. From the results of tile real recharge analysis for the study area using SCS-CN method, it was analyzed that the year 1994 when the drought was severe shotted the lowest recharge of 106.3mm with recharge rate of 12.4%, and the highest recharge of 285.6mm with recharge rate of 21.8% occurred in 1990. Yearly average recharge of 213.2mm was obtained, and tile average recharge rate was 16.9%/year. KOG-FLOW model which has powerful post process functions consists of setting environments for input parameters in Korean language, and help function is added to each input data. Detailed information for each parameter is displayed when the icon is placed on the input parameters, and geologic boundaries or initial head data for each layer can be set easily on work sheet. The relative errors (R. E.) for each model's observed values and calculated values are $0.156{\sim}0.432$ in case of KOG-FLOW, and $0.451{\sim}1.175$ in case of WINFLOW, therefore it is known that KOG-FLOW model developed in this study produced results compared to observed head values.

ESTIMATION OF NET GROUND WATER RECHARGE IN LARGE AQUIFER SYSTEMS BY GENETIC ALGORITHM: A CASE STUDY

  • K. Lakshmi Prasad;A. K. Rastogi
    • Water Engineering Research
    • /
    • v.2 no.3
    • /
    • pp.161-169
    • /
    • 2001
  • Present study deals with the development of a numerical model for the estimation of net annual recharge by coupling the Galerkin's finite element flow simulationl model with the Gauss-Newton-Marquardt optimization technique. The developed coupled numerical model is applied for estimating net annual recharge for Mahi Right Bank Canal (MRBC) project the norms of Groundwater Resources Estimation committee (1984, 1997) and Indian Agricultural research Institute(1983). It is observed that the estimated net recharge by inverse modeling is closer to the net recharge estimated using the water balance approach. Further it is observed that the computed head distribution from the estimated recharge agree closely with the observed head distribution. The study concludes that the developed model for inverse modeling can be successfully applied to large groundwater system involving regional aquifers where reliable recharge estimation always requires considerable time and financial resources.

  • PDF

Estimating groundwater recharge from time series measurements of subsurface temperature

  • Koo, Min-Ho;Kim, Yongje
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.213-216
    • /
    • 2003
  • Efforts for better understanding of the interaction between groundwater recharge and thermal regime of the subsurface medium is gaining momentum for its diverse applications in water resources. A numerical model is developed to simulate temperature variations of the subsurface under time varying groundwater recharge. The model utilizes MacCormack scheme for finite difference approximation of the partial differential equation describing the conductive and advective heat transport. For the estimation of recharge rate, optimization of the model is realized by searching for the unknown parameters which minimize the root-mean-square error between simulated and measured temperatures. Simulation results for 22-year time series data of temperature measurements reveal that the proposed model can accurately simulate subsurface temperature variations resulting from the redistribution of the heat due to the movement of water and it can also estimate temporal variations of recharge. Seasonal variations of recharge and a linear relationship between precipitation and recharge are clearly reflected in the simulated results.

  • PDF

A numerical analysis of precipitation recharge in the region of monsoon climates using an infiltration model

  • Koo, Min-Ho;Kim, Yongje
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.163-167
    • /
    • 2003
  • Based on the transient finite difference solution of Richards' equation, an infiltration model is developed to analyze temporal variation of precipitation recharge in the region of monsoon climates. Simulation results obtained by using time series data of 20-year daily precipitation and pan evaporation indicate that a linear relationship between the annual precipitation and the annual recharge holds for the soils under the monsoon climates with varying degrees of the correlation coefficient depending on the soil types. A sensitivity analysis reveals that the water table depth has little effects on the recharge for the sandy soil, whereas, for the loamy and silty soils, rise of the water table at shallow depths causes increase of evaporation by approximately 100㎜/yr and a corresponding decrease in recharge. A series of simulations for two-layered soils illustrate that the amount of recharge is dominantly determined by the soil properties of the upper layer, although the temporal variation of recharge is affected by both layers.

  • PDF

Modeling Artificial Groundwater Recharge in the Hancheon Drainage Area, Jeju island, Korea (제주도 한천유역 지하수 모델개발을 통한 인공함양 평가)

  • Oh, Se-Hyoung;Kim, Yong-Cheol;Koo, Min-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.6
    • /
    • pp.34-45
    • /
    • 2011
  • For the Hancheon drainage area in Jeju island, a groundwater flow model using Visual MODFLOW was developed to simulate artificial recharge through injection wells installed in the Hancheon reservoir. The model was used to analyze changes of the groundwater level and the water budget due to the artificial recharge. The model assumed that $2{\times}10^6m^3$ of storm water would recharge annually through the injection wells during the rainy season. The transient simulation results showed that the water level rose by 39.6 m at the nearest monitoring well and by 0.26 m at the well located 7 km downstream from the injection wells demonstrating a large extent of the affected area by the artificial recharge. It also shown that, at the time when the recharge ended in the 5th year, the water level increased by 81 m at the artificial reservoir and the radius of influence was about 2.1 km downstream toward the coast. The residence time of recharged groundwater was estimated to be no less than 5 years. The model also illustrated that 15 years of artificial recharge could increase the average linear velocity of groundwater up to 1540 m/yr, which showed 100 m/yr higher than before. Increase of groundwater storage due to artificial recharge was calculated to be $2.4{\times}10^6$ and $4.3{\times}10^6m^3$ at the end of the 5th and 10th years of artificial recharge, respectively. The rate of storage increase was gradually diminished afterwards, and storage increase of $5.0{\times}10^6m^3$ was retained after 15 years of artificial recharge. Conclusively, the artificial recharge system could augment $5.0{\times}10^6m^3$ of additional groundwater resources in the Hancheon area.

The Effect of Precipitation Change to the Groundwater Recharge (강수량 변화가 지하수함양량에 미치는 영향)

  • Lee, Seung-Hyun;Bae, Sang-Keun
    • Journal of Wetlands Research
    • /
    • v.13 no.3
    • /
    • pp.377-384
    • /
    • 2011
  • The objective of this research is to observe and to analyze how the precipitation change can affect urban area and coastal area to groundwater recharge. The variation in the precipitation data of the regional groundwater basin, which includes Busan Metropolitan City Suyeong Gu area, was to estimate the change in the groundwater recharge and to analyze the characteristic changes. Research result reflects that as the precipitation varied, there was some difference in the groundwater recharge. However, differences in the precipitation ratio and the groundwater recharge ratio were consistent. Variation in the precipitation had less impact on the groundwater recharge ratio, and the groundwater recharge ratio decreased as timeline increased. When the precipitation increased by 10 %, groundwater recharge changed by 2.23 %. Accordingly, when it decreased by 10 %, groundwater recharge changed by 2.20 %. When it increased by 20 %, groundwater recharge changed by 4.39 %, and when it decreased by 20 %, groundwater recharge changed by 4.36 %. Despite the dramatic changes in the precipitation, the changes in the groundwater recharge were minimal. From the research, we can observe that the precipitation change had a significant impact on the ratio, but it doesn't really affect the groundwater recharge. Therefore, in urban area, the changes in groundwater recharge don't conform to the changes in the precipitation, and the effect of direct runoff can increase the possible occurrence of urban flooding.

Estimation of Groundwater Recharge from Precipitation in a Small Basin (소유역의 강수에 의한 지하수 함양량 산정)

  • Bae, Sang-Keun;Lee, Seung-Hyun
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.5
    • /
    • pp.397-406
    • /
    • 2004
  • It is necessary to estimate the groundwater recharge rate properly to evaluate the reasonable development amount of groundwater in a specific site. A small basin in Wicheon River Basin located in the Province of Kyungsangbuk-Do is selected to calculate the groundwater recharge rate. Average annual groundwater recharge rates are calculated from 1992 to 1997 because wet and draught year are contained during this period. In the calculation, baseflow separation method and SCS-CN method are applied to this area. As a result of estimation by baseflow separation method, the value of groundwater recharge ratio is varied between 11.9% and 18.7%. The average annual recharge rate is 14.5%. The average annual recharge rate calculated by SCS-CN method is varied between 7.9% and 20.9%. The average annual recharge rate in the calculation period is 15.1%. The results show that the average annual recharge amount from infiltration in the study basin is 141.6mm and 147.4mm in each estimation method. It appears that the average annual recharge amount calculated for the long period containing wet and draught year by the two methods is useful for groundwater development.

Minimum Entropy Deconvolution을 이용한 지하수 상대 재충진양의 시계열 추정법

  • 김태희;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.574-578
    • /
    • 2003
  • There are so many methods to estimate the groundwater recharge. These methods can be categorized into four groups. First groupis related to the water balance analysis, second group is concerned with baseflow/springflow recession, and third group is interested in some types of tracers; environmental tracers and/or temperature profile. The limitation of these types of methods is that the estimated results of recharge are presented in the form of an average over some time period. Forth group has a little different approach. They use the time series data of hydraulic head and specific yield evaluated from field test, and the results of estimation are described in the sequential form. But their approach has a serious problem. The estimated results in forth typeof methods are generally underestimated because they cannot consider the discharge phase of water table fluctuation coupled with the recharge phase. Ketchum el. at. (2000) proposed calibrated method, considering recharge- and discharge-coupled water table fluctuation. But the dischargeis considered just as the areal average with discharge rate. On the other hand, there are many methods to estimate the source wavelet with observed data set in geophysics/signal processing and geophysical methods are rarely applied to the estimation of groundwater recharge. The purpose this study is the evaluation of the applicability of one of the geophysical method in the estimation of sequential recharge rate. The applied geophysical method is called minimum entropy deconvolution (MED). For this purpose, numerical modeling with linearized Boussinesq equation was applied. Using the synthesized hydraulic head through the numerical modeling, the relative sequenceof recharge is calculated inversely. Estimated results are very concordant with the applied recharge sequence. Cross-correlations between applied recharge sequence and the estimated results are above 0.985 in all study cases. Through the numerical test, the availability of MED in the estimation of the recharge sequence to groundwater was investigated

  • PDF

Site Prioritization for Artificial Recharge in Korea using GIS Mapping (지리정보시스템을 이용한 우리나라 인공함양 개발 유망지역 분석)

  • Seo, Jeong-A;Kim, Yong-Cheol;Kim, Jin-Sam;Kim, Yong-Je
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.6
    • /
    • pp.66-78
    • /
    • 2011
  • It is getting difficult to manage water resources in South Korea because more than half of annual precipitation is concentrated in the summer season and its intensity is increasing due to global warming and climate change. Artificial recharge schemes such as well recharge of surface water and roof-top rainwater harvesting can be a useful method to manage water resources in Korea. In this study, potential artificial recharge site is evaluated using geographic information system with hydrogeological and social factors. The hydrogeological factors include annual precipitation, geological classification based on geological map, specific capacity and depth to water level of national groundwater monitoring wells. These factors were selected to evaluate potential artificial recharge site because annual precipitation is closely related to source water availability for artificial recharge, geological features and specific capacity are related to injection capacity and depth to water is related to storage capacity of the subsurface medium. In addition to those hydrogeological factors, social aspect was taken into consideration by selecting the areas that is not serviced by national water works and have been suffered from drought. These factors are graded into five rates and integrated together in the GIS system resulting in spatial distribution of artificial recharge potential. Cheongsong, Yeongdeok in Gyeongsangbuk-do and Hadong in Gyeongsangnam-do, and Suncheon in Jeollanam-do were proven as favorable areas for applying artificial recharge schemes. Although the potential map for artificial recharge in South Korea developed in this study need to be improved by using other scientific factors such as evaporation and topographical features, and other social factors such as water-curtain cultivation area, hot spring resorts and industrial area where groundwater level is severely lowered, it can be used in a rough site-selection, preliminary and/or feasibility study for artificial recharge.