• Title/Summary/Keyword: reconstructed image

Search Result 1,120, Processing Time 0.025 seconds

Distortion Compensation of Reconstructed Hologram Image in Digital Holographic Display Based on Viewing Window

  • Park, Minsik;Kim, Hyun-Eui;Choo, Hyon-Gon;Kim, Jinwoong;Park, Cheong Hee
    • ETRI Journal
    • /
    • v.39 no.4
    • /
    • pp.480-492
    • /
    • 2017
  • A holographic display based on a viewing window enables the converging of a reconstruction wave into a viewing window by means of an optical system. Accordingly, a user can observe a reconstructed hologram image, even with a small diffraction angle. It is very difficult to manufacture an optical system with no aberrations; thus, it is inevitable that a certain amount of wave aberrations will exist. A viewing-window-based holographic display, therefore, always includes distortions in an image reconstructed from a hologram pattern. Compensating the distortions of a reconstructed image is a very important technical issue because it can dramatically improve the performance when reconstructing a digital three-dimensional content image from a hologram pattern. We therefore propose a method for suppressing image distortion by measuring and compensating the wave aberration calculated from a Zernike polynomial, which can represent arbitrary wave aberrations. Through our experimental configuration using only numerical calculations, our proposed method decreased the reconstructed image distortion by more than 28%.

High performance γ-ray imager using dual anti-mask method for the investigation of high-energy nuclear materials

  • Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2371-2376
    • /
    • 2021
  • As the γ-ray energy increases, a reconstructed image becomes noisy and blurred due to the penetration of the γ-ray through the coded mask. Therefore, the thickness of the coded mask was increased for high energy regions, resulting in severely decreased the performance of the detection efficiency due to self-collimation by the mask. In order to overcome the limitation, a modified uniformly redundant array γ-ray imaging system using dual anti-mask method was developed, and its performance was compared and evaluated in high-energy radiation region. In the dual anti-mask method, the two shadow images, including the subtraction of background events, can simultaneously contribute to the reconstructed image. Moreover, the reconstructed images using each shadow image were integrated using a hybrid update maximum likelihood expectation maximization (h-MLEM). Using the quantitative evaluation method, the performance of the dual anti-mask method was compared with the previously developed collimation methods. As the shadow image which was subtracted the background events leads to a higher-quality reconstructed image, the reconstructed image of the dual anti-mask method showed high performance among the three collimation methods. Finally, the quantitative evaluation method proves that the performance of the dual anti-mask method was better than that of the previously reconstruction methods.

The Utility Evaluation of Reconstructed 3-D Images by Maximum Intensity Projection in Magnetic Resonance Mammography and Cholangiopancreatography

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-Soo;Kim, Ham-Gyum;Baek, Jong-Geun;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.365-371
    • /
    • 2014
  • The aim of this study was to evaluate the utility of 3-D images by comparing and analyzing reconstructed 3-D images from fast spin echo images of MRI cholangiopancreatography (MRCP) images using maximum intensity projection (MIP) with the subtraction images derived from dynamic tests of magnetic resonance mammography. The study targeted 20 patients histologically diagnosed with pancreaticobiliary duct disease and 20 patients showing pancreaticobiliary duct diseases, where dynamic breast MR (magnetic resonance) images, fast spin echo imaged of pancreaticobiliary duct, and 3-D reconstitution images using a 1.5T MR scanner and 3.0T MR scanner were taken. As a result of the study, the signal-to-noise ratio in the subtracted breast image before and after administering the contrast agent and in the reconstructed 3-D breast image showed a high ratio in the reconstructed image of lesional tissue, relevant tissue, and fat tissue. However, no statistically meaningful differences were found in the contrast-to-noise ratio of the two images. In the case of the MRCP image, no differences were found in the ratios of the fast spin echo image and reconstructed 3-D image.

Extraction of location of 3-D object from CIIR method based on blur effect of reconstructed POI

  • Park, Seok-Chan;Kim, Seung-Cheol;Kim, Eun-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1363-1366
    • /
    • 2009
  • A new recognition method is used to find the three-dimensional target object on integral imaging. For finding the location of a target image, amount of reconstructed reference image is needed. This method is giving accurate information of target image by correlated among reconstructed target images and reference images.

  • PDF

Influence of CT Reconstruction on Spatial Resolution (CT 영상 재구성의 공간분해능에 대한 영향)

  • Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.85-91
    • /
    • 2018
  • Computed tomography, which obtains section images from reconstruction process using projection images, has been applied to various fields. The spatial resolution of the reconstructed image depends on the device used in CT system, the object, and the reconstruction process. In this paper, we investigates the effect of the number of projection images and the pixel size of the detector on the spatial resolution of the reconstructed image under the parallel beam geometry. The reconstruction program was written in Visual C++, and the matrix size of the reconstructed image was $512{\times}512$. The numerical bar phantom was constructed and the Min-Max method was introduced to evaluate the spatial resolution on the reconstructed image. When the number of projections used in reconstruction process was small, artifact like streak appeared and Min-Max was also low. The Min-Max showed upper saturation when the number of projections is increased. If the pixel size of the detector is reduced to 50% of the pixel size of the reconstructed image, the reconstructed image was perfectly recovered as the original phantom and the Min-Max decreased as increasing the detector pixel size. This study will be useful in determining the detector and the accuracy of rotation stage needed to achieve the spatial resolution required in the CT system.

DOMAIN BLOCK ESTIMATING FUNCTION FOR FRACTAL IMAGE CODING

  • Kousuke-Imamura;Yuuji-Tanaka;Hideo-Kuroda
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.57.2-62
    • /
    • 1999
  • Fractal coding is image compression techniques using one of image characteristics self-transformability. In fractal image coding, the encoding process is to select the domain block similar to a range block. The reconstructed image quality of fractal image coding depends on similitude between a range block and the selected domain block. Domain block similar to a range blocks. In fact, the error of the reconstructed image adds up the generated error in encoding process and the generated error in decoding process. But current domain block estimating function considered only the encoding error. We propose a domain block estimating function to consider not only the encoding error but also the decoding error. By computer simulation, it was verified to obtain the high quality reconstructed image.

Analysis of Image Distortion by Mandibular Arch Form in Cone Beam CT and Panoramic Image (Cone Beam형 CT와 파노라마 영상에서 하악궁의 영상 왜곡 분석)

  • Jeong, Cheonsoo;Lee, Geeheun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.301-305
    • /
    • 2013
  • This thesis intends to analyze tooth distortion by mandibular arch form by reproducing existing panorama image and reconstructed panorama image of Cone Beam CT data with the three-dimensional computer program. The diameter of tooth measured in Cone Beam CT's cross-section image and reconstructed panorama was synchronized without any big change from incisors to posteriors. But, panorama showed serious distortion as going to posteriors after showing a little distortion in incisors. The panorama reconstructed for patients' individual arch showed reduced distortion than panoramas used generally. In addition, panorama showed serious distortion from incisors to posteriors and it means that distortion is reduced in reconstructed panorama.

RELATIONSHIP BETWEEN ERROR DIFFUSION COEFFICIENTS, OBJECT SIZE AND OBJECT POSITION FOR CGH

  • Nishi, Susumu;Tanaka, Ken-ichi
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.492-497
    • /
    • 2009
  • Computer-Generated Hologram (CGH) is made for three dimensional image of a virtual object. Error diffusion method is used for the phase quantization of CGH, and it is known to be effective to the image quality improvement of the reconstructed image. However, the image quality of the reconstructed image from the CGH using error diffusion method depends on the selection of error diffusion coefficient. In this paper, we derived the relational expression to obtain the error diffusion coefficient from the position of the input object and size of the input object for CGH. As a result, the method of this thesis was able to obtain an excellent reconstructed image compared with the case to derive the error diffusion coefficient from only the position of the input image.

  • PDF

Spatial Frequency Coverage and Image Reconstruction for Photonic Integrated Interferometric Imaging System

  • Zhang, Wang;Ma, Hongliu;Huang, Kang
    • Current Optics and Photonics
    • /
    • v.5 no.6
    • /
    • pp.606-616
    • /
    • 2021
  • A photonic integrated interferometric imaging system possesses the characteristics of small-scale, low weight, low power consumption, and better image quality. It has potential application for replacing conventional large space telescopes. In this paper, the principle of photonic integrated interferometric imaging is investigated. A novel lenslet array arrangement and lenslet pairing approach are proposed, which are helpful in improving spatial frequency coverage. For the novel lenslet array arrangement, two short interference arms were evenly distributed between two adjacent long interference arms. Each lenslet in the array would be paired twice through the novel lenslet pairing approach. Moreover, the image reconstruction model for optical interferometric imaging based on compressed sensing was established. Image simulation results show that the peak signal to noise ratio (PSNR) of the reconstructed image based on compressive sensing is about 10 dB higher than that of the direct restored image. Meanwhile, the normalized mean square error (NMSE) of the direct restored image is approximately 0.38 higher than that of the reconstructed image. Structural similarity index measure (SSIM) of the reconstructed image based on compressed sensing is about 0.33 higher than that of the direct restored image. The increased spatial frequency coverage and image reconstruction approach jointly contribute to better image quality of the photonic integrated interferometric imaging system.

Adaptively Compensated-Disparity Prediction Scheme for Stereo Image Compression and Reconstruction (스테레오 영상 압축 및 복원을 위한 적응적 변이보상 예측기법)

  • 배경훈;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7A
    • /
    • pp.676-682
    • /
    • 2002
  • In this paper, an effective stereo image compression and reconstruction technique using a new adaptively compensated-disparity prediction scheme is proposed. That is, by adaptively predicting the mutual correlation between the stereo image using the proposed method, the bandwidth of the stereo input image can be compressed to the level of the conventional 2D image and the predicted image also can be effectively reconstructed using this transmitted reference image and disparity data in the receiver. Especially, in the proposed method, once the feature values are extracted from the input stereo image, then the matching window size for the predicted image reconstruction is adaptively selected in accordance with the magnitude of this feature values. From this adaptive disparity estimation method, reduction of the mismatching probability of the disparity vectors is expected and as a result, the image quality in the reconstructed image can be improved. In addition, from some experiments using the CCETT's stereo images of 'Fichier', 'Manege' and 'Tunnel', it is shown that the proposed method improves the PSNR of the reconstructed image to about 9.08 dB on average by comparing with that of the conventional methods. And also, it is found that there is almost no difference between the original image and the predicted image reconstructed through the proposed method by comparison to that of the conventional methods.