Calibration and Design of amulatory digital urodynamic study system (휴대용 디지털 요역동학검사장비의 설계와 Calibration)

  • Yoon, Dae-Young;Kim, Keo-Sik;Seo, Jeong-Hwan;Kim, Kyeong-Seop;Song, Chul-Gyu;Yang, Young-Kwang;Lee, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.313-315
    • /
    • 2004
  • Urodynamic study system is widely used for neurogenic bladder patients in various clinical setting. Generally they include 2 pressure sensors from bladder and rectum, and 1 EMG sensor. The rectal pressure catheter is often the source of data error because of gas passage and the fall out of the catheter from anus, and source of discomfort in ambulatory urodynamic system. This study is to design and calibrate the ambulatory digital urodynamic study system that can discard the rectal pressure catheter, which can make patients more comfortable and doctors can get more physiologic data. As a first step, we compared our new system with Dantec $Duet^{(r)}$ urodynamic system (Dantec, Denmark) and wanted to see the possibility of our new system.

  • PDF

Portable urodynamics monitoring system based on ubiquitous technology (유비쿼터스 기반 휴대용 방광기능 검사 장치)

  • Kim, Keo-Sik;An, Yang-Su;Song, Chul-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.43-45
    • /
    • 2007
  • We developed a portable urodynamics monitoring system using personal digital assistance (PDA) and proposed a new method for measuring the abdominal pressure in non invasive mode using surface EMG signals. This system is consisted of a signal conditioning and control module and could measure the vesical, abdominal and detrusor pressure. The result showed a high correlation coefficient between the practical abdominal pressure, using a conventional rectal catheter and the estimated values, by our proposed algorithm (r=0.81). This system should prove a useful tool in the future evaluations of ambulatory urodynamics monitoring study.

  • PDF

A Non-invasive Measurement of Abdominal Pressure on Ambulatory Urodynamics Study Using Surface Electromyography (휴대용 요역동학 검사 시 근전도 신호를 이용한 복압측정 방법)

  • Kim, Keo-Sik;Song, Chul-Gyu;Seo, Jeong-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.132-140
    • /
    • 2008
  • Conventional rectal catheters which are used for the measurement of abdominal pressure can cause erroneous result affecting detrusor pressure, and the catheter itself is not comfortable to the patients. To reduce these problems, we invented a new method for measuring abdominal pressure in non invasive manner using surface electromyography (EMG) signals of the rectus abdominis muscle. Our results showed that the correlation coefficient and root mean square error (RMSE) between the measured abdominal pressures by the conventional rectal catheters and the estimated values by our proposed algorithm were $0.79{\pm}0.06$ and $0.10{\pm}0.07$, respectively. These findings suggest that the surface EMG of rectus abdominis muscle might be used indirectly for more convenient measurement of abdominal pressure on ambulatory urodynamic study.