A study on the development and performance evaluation of reflective type Heart rate measurement system for PAPS (PAPS를 위한 반사형 맥파 측정 장치의 개발 및 성능 평가)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.1
    • /
    • pp.160-166
    • /
    • 2012
  • We performed the development and performance evaluation of reflective type heart rate measurement system for PAPS. We used chip LED and chip photo TR. for low power driving. The measured PPG signal is preprocessed using high pass filter and low pass filter, and the preprocessed signal is displayed by LabVIEW. Also LabVIEW include the algorithm that extract effective signal and calculate the heart rate. We made sure that it will be able to apply to measurement equipment with high accuracy and repetition from exercising subject using this system and algorithm.

A Study on Wrist Band Type Vital Sign Acquisition Device (손목형 생체신호수집 장치에 대한 연구)

  • Kim, Hee-Hoon;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.857-861
    • /
    • 2016
  • In this study, we proposed a new method that can be measure ECG (Electrocardiography) and PPG (Photoplethysmography) in realtime on the site of the wrist for check the state of health in daily life. For convenience measurement of ECG the lead I method was used on the wrist, and omit the reference junction ECG I was measured in the right hand and the left hand of the potential difference. Then the measured electrocardiogram was amplified by the differential amplifier and the signals were passed HPF, LPF, and BPF filters. For removing the PPG's noise from the Motion artifact and temperature, we apply the reflective photoelectric volume pulse wave measurement method using green LED as a light source. The circuits was designed to be able to check the waveform using higher active amplification method at weak signals. For the validation of our device, the measured signals were compared with E2-KIT on same time. The results shows that the error does not exceed the maximum one, most of the data is confirmed to be issued Peak inspection of the same number.

Ring-type Heart Rate Sensor and Monitoring system for Sensor Network Application (센서 네트워크 응용을 위한 반지형 맥박센서와 모니터링 시스템)

  • Jang, In-Hun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.5
    • /
    • pp.619-625
    • /
    • 2007
  • As low power, low cost wireless communication technology like Bluetooth, Zigbee, RFID has been put to practical use together with the wellbeing trend, the concern about ubiquitous health care has been greatly increased and u-Health is becoming one of the most important application in the sensor network field. Especially, development of the medical services to be able to cope with a state of emergency for solitary senior citizens and the aged in silver town is very meaningful itself and their needs are also expected to continuously increase with a rapid increase in an aging population. In this paper we demonstrate the feasibility of extracting accurate heart rate variability (HRV) measurements from photoelectric plethysmography(PPG) signals gathered by a ring type pulse oximeter sensor attached to the finger. For this, we made 2 types of ring sensor, that is reflective and pervious type, and developed the remote monitoring system which is able to collect HR data from ring sensor, analyze and cope with a state of emergency.

Non-intrusive measurement of pulse arrival time and Estimation of Systolic Blood Pressure (무구속적 맥파 전달 시간의 측정을 통한 혈압 추정)

  • Chee, Young-Joon;Park, Kwang-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.489-492
    • /
    • 2005
  • Even though the blood pressure is one of the most widely used index for the healthcare monitoring of hypertensive and normotensive persons, there is no non-intrusive measurement method which is commercialized until now. Pulse Arrival Time (PAT) is known that it has close relation with the systolic blood pressure (SBP) and arterial stiffness. In this study, SBP estimation methods by non-intrusive measurement of PAT are suggested. For the unconstrained measurement of PAT, the first method used the electrically non contact electrocardiogram (ENC-ECG) technique and the reflective type of Photoplethysmography (PPG) sensor on the computer mouse. In the second method, ENC-ECG and the air pressure sensor in the seat cushion on a chair were measured. The third method used ECG electrodes and PPG sensors on the toilet seat cover. The validation and regression analysis of the relationship of PAT and SBP are summarized. These methods have considerable errors to be used for all people. But these can be applied for each subject after the parameter customization within acceptable error. So, it is feasible for suggested methods to be used for monitoring of SBP in daily life in non-intrusive way when there is personal identification system of each subject.