• Title/Summary/Keyword: robotic locomotion

Search Result 28, Processing Time 0.028 seconds

Multifunctional Robotic Guidewire System using Spiral-type Magnetic Microrobot with Magnetic Manipulation

  • Yu, Chang-Ho;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.616-621
    • /
    • 2016
  • This paper presents a new multifunctional active guidewire system for medical applications that uses a magnetic microrobot. The study demonstrated that the proposed microrobot system could swim and be controlled under Low-Reynolds-number (Re) environments in blood vessel models. The prototype of the robotic guidewire, which is driven within a three-axis Helmholtz coil system, consists of a guide-wire, spiral blade, drilling tip, and permanent magnet. The spiral-type microrobot showed stable active locomotion between 3 kA/m and 9.1 kA/m under driving frequency up to 70 Hz in a silicone oil (of viscosity 1000 cst). The microrobot produced a maximum moving velocity of $8.08{\times}10^{-3}m/s$ at 70 Hz and 9.1 kA/m. In particular, the robotic guidewire produced 3D locomotion with drilling in the three-axis Helmholtz coil system. We verified active locomotion, towing of guidewire, steering, and drilling of the proposed robotic guidewire system through experimental analyses.

A Navigation Algorithm using Locomotion Interface with Two 6-DOF Robotic Manipulators (ICCAS 2005)

  • Yoon, Jung-Won;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2211-2216
    • /
    • 2005
  • This paper describes a novel navigation algorithm using a locomotion interface with two 6-DOF parallel robotic manipulators. The suggested novel navigation system can induce user's real walking and generate realistic visual feedback during navigation, using robotic manipulators. For realistic visual feedback, the virtual environment is designed with three components; 3D object modeler for buildings and terrains, scene manager and communication manager component. The walking velocity of the user is directly translated to VR actions for navigation. Finally, the functions of the RPC interface are utilized for each interaction mode. The suggested navigation system can allow a user to explore into various virtual terrains with real walking and realistic visual feedback.

  • PDF

Analysis for Movement Characteristics of Pneumatic Impulsive Actuator for Robotic Colonoscope (내시경용 로봇을 위한 공압구동기의 운동특성 해석)

  • Lee, Jin-Hui;Jeong, Yeon-Gu;Gang, Byeong-Gyu;Park, Jong-O
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1638-1644
    • /
    • 2002
  • A novel locomotion using the pneumatic impulsive actuator was proposed for robotic colonoscope. This locomotion showed good moving performance in the environment of rigid pipe, however, the displacement per one impact(step displacement) is greatly reduced due to the low stiffness and high damping characteristics of the colon. Therefore, the modeling technique based on spring and damping system is studied to predict the step displacement and some parametric studies are carried out to investigate main parameters that influence the step displacement of locomotion. Based on simulation result, a new locomotion to control the resistance force is suggested and fabricated. Through the experiment on the colon, the usefulness of modeling technique is confirmed and successful improvement of moving characteristics is achieved.

Inverse Dynamic Modeling of a Stair-Climbing Robotic Platform with Flip Locomotion (회전과 뒤집기 방식의 계단등반 로봇의 역동역학 모델링)

  • Choi, Jae Neung;Jeong, Kyungmin;Seo, TaeWon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.654-661
    • /
    • 2015
  • Stairs are the most popular obstacles in buildings and factories. To enlarge the application areas of a field robotic platform, stair-climbing is very important mission. One important reason why a stair-climbing is difficult is that stairs are various in sizes. To achieve autonomous climbing of various-sized stairs, dynamic modeling is essential. In this research, an inverse dynamic modeling is performed to enable an autonomous stair climbing. Stair-climbing robotic platform with flip locomotion, named FilpBot, is analyzed. The FlipBot platform has advantages of robust stair-climbing of various sizes with constant speed, but the autonomous operation is not yet capable. Based on external constraints and the postures of the robot, inverse dynamic models are derived. The models are switched by the constraints and postures to analyze the continuous motion during stair-climbing. The constraints are changed according to the stair size, therefore the analysis results are different each other. The results of the inverse dynamic modeling are going to be used in motor design and autonomous control of the robotic platform.

Effect of Leg Stiffness on the Running Performance of Milli-Scale Six-Leg Crawling Robot with Payload (소형 6족 주행 로봇의 페이로드와 다리 강성이 로봇의 주행 성능에 미치는 영향)

  • Chae, Soo-Hwan;Baek, Sang-Min;Lee, Jongeun;Yim, Sojung;Ryu, Jae-Kwan;Jo, Yong-Jin;Cho, Kyu-Jin
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.4
    • /
    • pp.270-277
    • /
    • 2019
  • Inspired by small insects, which perform rapid and stable locomotion based on body softness and tripod gait, various milli-scale six-legged crawling robots were developed to move rapidly in harsh environment. In particular, cockroach's leg compliance was resembled to enhance the locomotion performance of the crawling robots. In this paper, we investigated the effects of changing leg compliance for the locomotion performance of the small light weight legged crawling robot under various payload condition. First, we developed robust milli-scale six-leg crawling robot which actuated by one motor and fabricated in SCM method with light and soft material. Using this robot platform, we measured the running velocity of the robot depending on the leg stiffness and payload. In result, there was optimal range of the leg stiffness enhancing the locomotion ability at each payload condition in the experiment. It suggests that the performance of the crawling robot can be improved by adjusting stiffness of the legs in given payload condition.

Modular Crawler with Adjustable Number of Legs and Performance Evaluation of Hexapod Robot (다리 수 조절이 가능한 모듈러 크롤러의 설계 및 6족 로봇의 주행 성능 평가)

  • Yim, Sojung;Baek, Sang-Min;Lee, Jongeun;Chae, Soo-Hwan;Ryu, Jae-Kwan;Jo, Yong-Jin;Cho, Kyu-Jin
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.4
    • /
    • pp.278-284
    • /
    • 2019
  • Legged locomotion has high mobility on irregular surfaces by touching the ground at discrete points. Inspired by the creature's legged locomotion, legged robots have been developed to explore unstructured environments. In this paper, we propose a modular crawler that can easily adjust the number of legs for adapting the environment that the robot should move. One module has a pair of legs, so the number of legs can be adjusted by changing the number of modules. All legs are driven by a single driving motor for simple and compact design, so the driving axle of each module is connected by the universal joint. Universal joints between modules enable the body flexion for steering or overcoming higher obstacles. A prototype of crawler with three modules is built and the driving performance and the effect of module lifting on the ability to overcome obstacles are demonstrated by the experiments.

A Development of 4-legged Walking Machine and the Enhancement of Static Stability Margin Using Balancing Weight (사각 보행 로보트의 제작 및 균형추를 이용한 안정성 향상에 관한 연구)

  • 강신천;오준호;정경민
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.146-154
    • /
    • 1991
  • As the application of robotic systems expand its scope, more research efforts are given in providing mobility to the robotic systems so that they can travel across various paths including those with formidable obstacles such as stairways or rough terrains. Legged locomotion is mainly concerned because the walking motion, like that of animal behavior, has many advantages over wheel type or track type locomotion especially in rough terrain. Walking robot, in general, having a discrete number of legs, have inherently low static stability. Static stability can be increased to a certain degree, by improving walking method, but it has many limitations such as reduced travel speed. A very promising possibility lies in the use of balancing weight, nevertheless its actual implementation is very rare. In this study, a 4-legged walking machine is developed and the static stability margin is increased with the balancing weight. In the future, this robot will be used to take an experiment on the walking in mush terrain.

  • PDF

Locomotive Mechanism with Cam for a Robotic Colonoscope (대장 내시경용 캠구동 방식 이동메커니즘)

  • Park, Ji-Sang;Kim, Byung-Kyu;Kim, Kyoung-Dae;Park, Jong-Oh;Kim, Soo-Hyun;Hong, Yeh-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.271-276
    • /
    • 2001
  • Conventional clonoscope is semiflexible tube that should be manipulated by operator for inspection and treatment. Therefore, it sometimes causes pain for the patient and even perforation to the wall of colon if a surgeon is not well trained. For safe colonoscopy, self-propelling robots with inchworm locomotion are studied. But, inchworm locomotion has some problems in adaptiveness to the variation of colon diameter. In this paper, we propose novel locomotive mechanism which can move in the colon without any external assistance. It has several cams that have constant phase difference each other and located along the centerline of the mechanism. This mechanism could realize the robotic endoscope which has continuous and smooth thrust force.

  • PDF

Magnetic Impact Actuator for Robotic Endoscope (대장내시경을 위한 자기 충격 액츄에이터)

  • 민현진;임형준;김병규;김수현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.839-843
    • /
    • 2001
  • For robotic endoscope, some researchers suggest pneumatic actuators based on inchworm motion. But, the existing endoscopes are not seemed to be replaced completely because human intestine is very sensitive and susceptible to damage. We design and test a new locomotion of robotic endoscope able to maneuver safely in the human intestine. The actuating mechanism is composed of two solenoids at each side and a single permanent magnet. When the current direction is reversed, repulsive force and attractive at the opposition side propels permanent magnet. Impact force against robotic endoscope transfer momentum from moving magnet to endoscope capsule. The direction and moving speed of the actuator can be controlled by adjusting impact force. Modeling and simulation experiments are carried out to predict the performance of the actuator. Simulation experiments show that force profile of permanent magnet is the dominant factor for the characteristic of the actuator. The results of simulations are verified by comparing with the experimental results.

  • PDF

Hydrodynamics Analysis of Fish Locomotion Using a Biomimetic Fish Robot (생체모사 물고기 로봇을 이용한 물고기 운동의 유체역학적 해석)

  • Han, Cheol-Heui;Lee, Seung-Hee;Shin, Chang-Rok;Park, Jong-Hyeon
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.435-440
    • /
    • 2007
  • Fish-mimetic robots or fish-mimetic propulsors have been developed or under construction. A mechanical system cannot have the same functions as bio-organic systems. Thus, the hydrodynamic characteristics of fish locomotion should be well understood in order to develop and control a feasible intelligent fish-mimetic robot with its optimal motion pattern known. In this paper, a mackerel-mimetic robot fish is fabricated in order to understand the hydrodynamic characteristics of fish locomotion. A simplified unsteady flow theory is also applied to the hydrodynamic analysis of the motion of the anterior part of the robotic fish. The normal and axial forces of the fish are measured by changing the amplitude and frequencies of fanning motion. It is found that the present theoretical results agree with the measured data.

  • PDF