• Title/Summary/Keyword: scanner

Search Result 2,017, Processing Time 0.029 seconds

Comparison of 2-dimensional marginal and internal fitness for the monolithic zirconia prosthesis using intraoral scanner and extraoral scanner: in vitro (Extraoral scanner와 intraoral scanner를 이용하여 제작된 zirconia crown의 2차원 변연 및 내면 적합도 비교: in vitro)

  • Lee, Tae-Hee;Lee, Ha-Bin;Kim, Ji-hwan
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.187-193
    • /
    • 2019
  • Purpose: The purpose of this study was to compare two-dimensional fitness of the monolithic zirconia prosthesis by using different type of scanner. Methods: No. 26 abutment tooth of FDI system was selected for the study. Using the extraoral scanner and intraoral scanner, the abutment tooth was scanned 10 times and the scanned files were saved as STL files. CAD/CAM system was used to produce the monolithic zirconia prosthesis. marginal and internal gap of the monolithic zirconia prosthesis were measured by digital microscope(x160) and applied silicone replica technique was applied. t-test, a statistical software, was used to perform data analysis. Results: Marginal gap $mean{\pm}SD$ of the monolithic zirconia prosthesis was $33{\pm}7.5{\mu}m$ with extra oral scanner and $34.7{\pm}11.1{\mu}m$ with intraoral scanner. axial gap mean was $40.5{\pm}3.5{\mu}m$ with extra oral scanner and $44.6{\pm}11.6{\mu}m$ with intraoral scanner. occlusal gap mean was $110.1{\pm}25.4{\mu}m$ with extra oral scanner and $64{\pm}9.7{\mu}m$ with intraoral scanner. Conclusion: In this study, fabricating zirconia prosthesis with different type of scanner was clinically applicable.

Comparison of the accuracy of domestic dental intra-oral scanner(e-scanner) and model scanner (국산 치과용 구강스캐너(e-scanner)와 모델스캐너의 정확도 비교)

  • Kim, Busob;Kim, Jungho
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.53-61
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the discrepancy of scan process in dental intra oral scanner by comparing model scanner and anticipate possibility to introduce intra oral scan technique. Methods: 3D superimposition test was conducted to compare the scan discrepancy. The scanners used in this study are the e-oral scanner, the D750 model scanner, and the high precision CMM(3D Coordinate Measuring Machine). The standard of accuracy verification is ISO 5725-1; trueness and precision. Master model was manufactured by dental stone and scanned 5 times by intra oral, model scanner. Reference data was scanned 5 times by high accuracy CMM to evaluate the trueness. Results: Trueness of D750 scanner were $7.4{\mu}m$ $5.1{\mu}m$ $6.8{\mu}m$ at an abutment, an occluasal, a specific area. and trueness of e-scanner were $20.2{\mu}m$ $27.4{\mu}m$ $37.8{\mu}m$ at an abutment, an occluasal, a specific area. Precision of D750 scanner was $7.04{\mu}m$, e-scanner was $15.95{\mu}m$. Conclusion: When conducting in vitro test, The mean difference of trueness between e-scanner and D750 were $12.8{\mu}m$ at an abutment area, $22.3{\mu}m$ at an occlusal area, $31.0{\mu}m$ at a specific area and $8.91{\mu}m$ in precision. The scan discrepancies are within the range of clinical acceptance.

A Study on the recognition of moving objects by segmenting 2D Laser Scanner points (2D Laser Scanner 포인트의 자동 분리를 통한 이동체의 구분에 관한 연구)

  • Lee Sang-Yeop;Han Soo-Hee;Yu Ki-Yun
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.177-180
    • /
    • 2006
  • In this paper we proposed a method of automatic point segmentation acquired by 2D laser scanner to recognize moving objects. Recently, Laser scanner is noticed as a new method in the field of close range 3D modeling. But the majority of the researches are pointed on precise 3D modeling of static objects using expensive 3D laser scanner. 2D laser scanner is relatively cheap and can obtain 2D coordinate information of moving object's surface or can be utilized as 3D laser scanner by rotating the system body. In these reasons, some researches are in progress, which are adopting 2D laser scanner to robot control systems or detection of objects moving along linear trajectory. In our study, we automatically segmented point data of 2D laser scanner thus we could recognize each of the object passing through a section.

  • PDF

Comparison of accuracy of digital data obtained by intra-oral scanner and extra-oral scanner (구강 내 스캐너와 구강 외 스캐너를 사용하여 취득된 스캔 데이터 정확도 비교)

  • Lee, Jae-Jun;Jeong, Il-Do;Kim, Chong-Myung;Park, Jin-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.191-197
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accuracy of the scan data acquired by the extra-oral and intra-oral scanner. Methods: The maxillary right first molar was made of polymethyl methacrylate(PMMA) specimen. This PMMA specimen was scanned with a engineering scanner and intra-oral scanner. Meanwhile, extra-oral scanner scanned stone die duplicated from PMMA master die. Trueness and precision of scan datas was measured by 3-dimensinal inspection. Independent t-test was conduct to analysis the significant difference(a=0.05). Results: In the trueness analysis, mean of discrepancies were 13.82um for intra oral scanner and 16.84 um for extra-oral scanner. In the precision analysis, mean of discrepancies were 11.72 for inta-oral scanner and 9.2 for extra-oral scanner. Both trueness and precision showed a statistically significant difference (Table 1, p<0.05). Conclusion: Intra-oral scanner can show higher trueness than extra-oral scanner, it has lower precision.

Development of a 3D Laser Scanner Based Tunnel Scanner (3D 레이저 스캐너 기반의 터널스캐너 개발)

  • SaGong, Myung;Moon, Chul-Yi;Lee, Jun-S.;Hwang, Seon-Keun;Kim, Byung-Hong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.4
    • /
    • pp.377-388
    • /
    • 2006
  • Most structures experience deterioration after construction. A routine inspection and maintenance must be accomplished for the efficient use of the structures. The routine inspection will play a major role on the determination of maintenance period and method. This study aims development of an automated tunnel inspection system based upon a 3 dimensional laser scanner. As for the initial stage of the project, a prototype tunnel scanner has been developed. The development of a tunnel scanner prototype follows comparison between image scanning and laser scanning system and investigation on the applicability and adaptivity of the scanners to the railway tunnel scanner. The applicability of the laser scanner on the railway tunnel has been confirmed from the pilot test by using commercialized general purpose close range laser scanner and applicability of a laser scanner as a railway tunnel scanner has been checked. From the result, a prototype of railway tunnel scanner has been built and the calibration of the system was carried out. Finally the developed tunnel laser scanner has been applied to different shapes and sizes of tunnels in use.

Improvement of Reflection Angle of Optical Scanner Utilizing Magnetic Effect (자기효과를 이용한 광 Scanner의 반사각 개선)

  • Kim, Hung-Gun;Park, Kyung-Il;Shin, Kwang-Ho;SaGong, Geon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1718-1720
    • /
    • 2004
  • This paper is focused on the improvement of reflection angle of an optical scanner by changing a shape of a torsion bar attached with an optical scanner reflector(mirror). In order to improve the light efficiency of the optical scanner by virtue of the magnetic effect, which tiny magnets are attached under both ends of the optical scanner reflector. and hence the optical scanner reflector was operated in relatively lower driving voltage. By changing the torsion bar's shape I type into S type, we've got the lower resonant frequency(32.5Hz) of an optical scanner than that of conventional one(50Hz). According to these results. The reflection angle of an optical scanner with magnets was much larger in the range of about 14.8$^{circ}$ without a magnet. By making use of a magnetic actuator instead of a conventional electrostatic actuator, the optical scanner was less influenced from outdoor dust or moisture.

  • PDF

3D Boundary Extraction of A Building Using Terrestrial Laser Scanner (지상라이다를 이용한 건축물의 3차원 경계 추출)

  • Lee, In-Su
    • Spatial Information Research
    • /
    • v.15 no.1
    • /
    • pp.53-65
    • /
    • 2007
  • Terrestrial laser scanner provides highly accurate, 3D images and by sweeping a laser beam over a scene or object, the laser scanner is able to record millions of 3D points' coordinates in a short period, so becoming distinguished in various application fields as one of the representative surveying instruments. This study deals with 3D building boundary extraction using Terrestrial Laser Scanner. The results shows that high accuracy 3D coordinates for building boundaries are possibly acquired fast, but terrestrial laser scanner is a ground-based system, so "no roofs", and "no lower part of building" due to trees and electric-poles, etc. It is expected that the combination of total station, terrestrial laser scanner, airborne laser scanner with aerial photogrammetry will contribute to the acquisition of an effective 3D spatial information.

  • PDF

Multi-facet 3D Scanner Based on Stripe Laser Light Image (선형 레이저 광 영상기반 다면 3 차원 스캐너)

  • Ko, Young-Jun;Yi, Soo-Yeong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.10
    • /
    • pp.811-816
    • /
    • 2016
  • In light of recently developed 3D printers for rapid prototyping, there is increasing attention on the 3D scanner as a 3D data acquisition system for an existing object. This paper presents a prototypical 3D scanner based on a striped laser light image. In order to solve the problem of shadowy areas, the proposed 3D scanner has two cameras with one laser light source. By using a horizontal rotation table and a rotational arm rotating about the latitudinal axis, the scanner is able to scan in all directions. To remove an additional optical filter for laser light pixel extraction of an image, we have adopted a differential image method with laser light modulation. Experimental results show that the scanner's 3D data acquisition performance exhibited less than 0.2 mm of measurement error. Therefore, this scanner has proven that it is possible to reconstruct an object's 3D surface from point cloud data using a 3D scanner, enabling reproduction of the object using a commercially available 3D printer.

Comparative assessment of a 1.5T endorectal coil and a 3.0T phased-array coil available for prostate MRI (전립선 MRI에서 사용하는 1.5T 경직장 코일과 3.0T 위상 배열 코일의 성능 비교 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.3
    • /
    • pp.283-290
    • /
    • 2010
  • The effectiveness of 3.0T phase array coil images was tested by comparing signal-to-noise ratios for the same coil images relative to 1.5T endorectal coil images. Signal intensities were measured in the three regions of prostate, central and peripheral (right and left) after 40 patients with prostate cancer were imaged during the period between Jan. 2008 and Oct. 2009 with T2 W, T1 W, and DW images obtained respectively using endorectal coil on a 1.5T MR scanner and phase array coil on a 3.0T MR scanner. For quantitative analysis, comparisons of average SNRs for the same ROIs were made between groups scanned with a 1.5T and a 3.0T MR scanner. The signal-to-noise ratios were shown to increase more sharply when using a phase array coil at a 3.0T MR scanner compared to using an endorectal coil at a 1.5T MR scanner.

Development of a Flatbed Scanner for Reflection Infrared Photography (반사 적외선 사진을 위한 평판 스캐너의 개발)

  • Choi, Young-Ho;Hwang, Min-Ku;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.57-66
    • /
    • 2011
  • At this time, digital cameras are used in art and forensic science. However, the digital camera has some limitations which need to understand of photograph and lighting. It is a useful paper to make an infrared flatbed scanner. The following processes offer an infrared flatbed scanner development. First, the infrared flatbed scanner changes visible fluorescent lamp to infrared LED. Second, it equips a long-pass filter, which is available to pass over 810nm wavelength, on the glass to complete the optimal infrared flatbed scanner. In addition, it must copy from digital camera to computer directly. The infrared digital camera has disadvantage to always irradiate infrared lamp. Because of difference between visible length and infrared length characteristic, they have different focal distance. This devised scanner for solving mentioned problems does not need to irradiate infrared lamp, and there is not a problem about focal point because the depth of field of flatbed scanner is minimum 2mm. Lastly, the infrared flatbed scanner can make high resolution which is 12,800dpi unlike digital camera. Accordingly, the infrared scanner looks forward to be used in many field of study.