• Title/Summary/Keyword: scanner

Search Result 2,018, Processing Time 0.037 seconds

The Development of High Resolution Film Scanner Using DSP (DSP를 이용한 고해상도 스캐너 개발)

  • 김태현;최은석;백중환
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.12a
    • /
    • pp.149-152
    • /
    • 2000
  • A scanner is an output device that scans documents, photographs, films etc, and convert them to digital data. Especially, a film scanner is used for scanning negative/positive films. In this paper, we design step motor control part, image sensor part, and Aか converter part which are components of the scanner and use DSP for fast signal processing. We also design the interface circuits using EPLD between these peripherals and DSP. The PC interface circuits between scanner and PC are designed by using parallel port to control and transfer the scanned data from scanner to PC. For 35mm film, we design hardwares which obtain high resolution more than 9 million pixels (horizontal resolution is 3835 and vertical resolution is 2592).

  • PDF

Super Multi-View 3-D Display System using Vibrating Scanner Array(ViSA)

  • Jeon, Ho-In;Jung, Nak-Hee;Choi, Jin-San;Kang, Yo-Seek;Choi, Se-Ha;Shin, Sang-Hun;Son, Jung-Yung
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.37-42
    • /
    • 2000
  • In this paper, we propose a super multi-view (SMV) 3-D display system using a vibrating scanner array (ViSA). The parallel beam scanning using a vibrating scanner array is performed by moving back and forth an array of curvature-compensated mirrors attached to two vibrating membranes. The parallel laser beam scanner array can replace the polygon mirror scanner which has been used in the SMV 3-D display system based on the focused light array(FLA) concept. The proposed system has great advantages in the sense that it requires neither huge imaging optics normechanical scanning parts. Some mathematical analyses and fundamental limitations of the proposed system are presented. The proposed vibrating scanner array, after some modifications and refinements, will replace polygon mirror-based scanners in the near future.

Development of a Sample Scanner for Atomic Force Microscope (원자 현미경용 샘플 스캐너의 개발)

  • Lee, Dong-Yeon;Lee, Moo-Yeon;Gweon, Dae-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.879-882
    • /
    • 2005
  • This paper shows a method for design of the nano-positioning planar scanner used in the scanning probe microscope. The planar scanner is composed of flexure guides, piezoelectric actuators and feedback sensors. In the design of flexure guides, the Castigliano's theorem was used to find the stiffness of the guide. The motion amplifying mechanism was used in the piezoelectric actuator to achieve a large travel range. We found theoretically the travel range of the total system and verified using the commercial FEM(Finite element method) program. The maximum travel range of the planar scanner is above than 140 $\mu$m. The 3 axis positioning capability was verified by the mode analysis using the FEM program. Moreover, we presented the actual AFM(Atomic Force Microscope) imaging results with up to 2Hz imaging scan rate. Experimental results show that the properties of the proposed planar scanner is well enough to be used in SPM applications like AFM.

  • PDF

Evaluation of the Model Accuracy according to Three Types of Dental Scanner (세 가지 방식의 스캐너 종류에 따른 모형 정확도 평가)

  • Lee, Jae-Jun;Park, Jin-Young;Bae, So-Yeon;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.226-231
    • /
    • 2015
  • The purpose of this study was to evaluate the accuracy of model according to three types of dental scanner. A maxillary acrylic model was prepared and duplicated 10 times by silicone impression materials. Corresponding working casts were formed from scannable stone and got a 3-dimensional digital models using three different scanners. The distance of each measurement region was measured using vernier calipers and the respective program. One-way ANOVA and the Tukey honestly significant difference post hoc test (${\alpha}=0.05$) was performed using IBM SPSS Statistics 21.0. Overall, the stone cast is smaller than the digital models in measurement distance. And measuring point value of laser scanner showed the most similar values and measurement points value of digital vernier calipers. Digital model of white light scanner showed similar values in the measurement points value of the blue light scanner. In conclusion, the laser scanner showed the best accuracy among the three types of dental scanner. However, the difference between the digital models and the stone cast can be accommodated in making prostheses. Thereby, three types of dental scanner are available in a clinically acceptable range.

Evaluation on the repeatability of dental white light scanner-based digital impression (치과용 백색광 스캐너를 이용한 impression scanning의 반복 측정에 대한 안정성 평가)

  • Jeon, Jin-Hun;Lee, Kyung-Tak;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.35 no.1
    • /
    • pp.37-42
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the repeatability of dental white light scanner. Methods: The impression(Zerosil, Dreve, Germany) were digitized in white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The distribution of the discrepancies between the number of points in the corresponding CRM models and the point clouds in the others were measured by a matching-software(PowerInspect 2012, Delcam Plc, UK). The discriptive statistics were used for statistical analysis(SPSS 20.0). Results: The measurement of repeatablity showed very good reliability. The mean(SD) discrepancy value on the white light scanner digital models was 8.7(0.67) ${\mu}m$, based on SD and absolute mean values. Conclusion: These in vitro studies showed that repeatability of dental white light scanner is high reliability. These results can be confirmed in further clinical studies.

The construction management of tunnel using 3D laser scanner (3차원 레이저 스캐너를 활용한 터널 시공관리)

  • Lee, Kang-Hyun;Heo, In-Wook;Kim, Do-Hoon;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.3
    • /
    • pp.159-176
    • /
    • 2011
  • A 3D laser scanner is widely used in various fields such as games, movies, medicines, art, design, etc. Many studies for utilizing the 3D laser scanner in the fields of civil engineering have also been carried out, for example, for systematically managing tunnel and/or bridge construction. However, since a software which is directly applicable to Korean construction system does not exist, the amount of data obtained from existing the 3D laser scanner is too much to handle in a systematic way. Therefore, in this paper, a new data processing technique was established which can rapidly and effectively treat the 3D laser scanning data. Moreover, a software that can systematically manage the tunnel construction was developed. The developed software can assess the construction quality of tunnel excavation such as under-break, over-break, cracks, leakage and efflorescence, etc. A 3D laser scanner and the developed software was applied to an in-situ tunnelling site, and verified usefulness of the 3D laser scanner. The developed software may be useful for tunnel maintenance as well as for systematic management of tunnel construction.

Measuring Leaf Areas with a Structured-Light 3D Scanner (3차원 구조광 스캐너를 이용한 식물의 잎 면적 측정 방법)

  • Nam, Kyong-Hee;Ko, Eun Mi;Mun, Saeromi;Kim, Chang-Gi
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.3
    • /
    • pp.232-238
    • /
    • 2014
  • We have developed a non-destructive, touch-free method for estimating leaf areas with a structured-light three-dimensional (3D) scanner. When the surfaces of soybean leaves were analyzed with both the 3D scanner and a leaf area meter, the results were linearly related ($R^2=0.90$). The strong correlation ($R^2=0.98$) was calculated between shoot fresh weights and leaf areas when the scanner was employed during growth stages V1 to V4. We also found that leaf areas measured by the scanner could be used to detect changes in growth responses to abiotic stress. Whereas under control conditions the areas increased over time, salt and drought treatments were associated with reductions in those values after 14 d and 12 d, respectively. Based on our findings, we propose that a structured-light 3D scanner can be used to obtain reliable estimates of leaf area and plant biomass.

A Study on the Radiation Dose in Computed Tomographic Examinations (전산화단층촬영 검사의 방사선 선량에 관한 연구)

  • Lim, Chung-Hwang;Cho, Jung-Keun;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.381-389
    • /
    • 2007
  • The purpose of this study is investigation of radiation dose in CT scan. Data were collected from various references and organizations. Doses measured by CT scanners of each medical organization were analyzed and they were calculated through the examination protocol. The results are as follows : 1. $CTDI_W$ value per 100mAs measured by Head Phantom was the highest in <4-slice MDCT scanner> of 24.20 mGy. $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 2. $CTDI_W$ value per 100 mAs measured using body phantom was the highest in <4-slice MDCT scanner> of 13.58 mGy and the $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 3. When contrast medium was not used, the highest scanner was <16 slice MDCT> of $818.83\;mGy{\codt}cm$ in exposure dose in brain scan(p < 0.05). When the contrast medium was used, the highest scanner was <4 slice MDCT> and its average was $1,460.77\;mGy{\cdot}cm$(p < 0.1). 4. When the contrast medium was not used, the highest scanner was <16-slice MDCT> of $521.63\;mGy{\cdot}cm$ on average in terms of the exposure dose in chest inspection(p<0.05). when the contrast medium was used, the highest scanner was found in 8 slice MDCT scanner and its average was $1,174.70\;mGy{\cdot}cm$. There was no statistically significant difference among scanners. 5. When the contrast medium was not used, the highest scanner was <16-slice MDCT> and its average was $856.27\;mGy{\cdot}cm$ in exposure dose on the abdomen-pelvis(p<0.05). when the contrast medium was used, the highest scanner was <16-slice MDCT> and its average was $1,720.64\;mGy{\cdot}cm$ on average (p < 0.05). 6. When the contrast medium was not used, the highest scanner was <8-slice MDCT> and its average was $612.07\;mGy{\cdot}cm$ in exposure dose in liver inspection(p < 0.05). when the contrast medium was used, the highest scanner was <8-slice MDCT scanner> and its average was $2,197.93\;mGy{\cdot}cm$ in exposure dose(p < 0.1). seventy six point two percent of medical facilities were in risk of radiation exposure while the number of phase was three to four times in their dose inspection of contrast medium.

  • PDF

Comparative Analysis of Focal Length Bias for Three Different Line Scanners (초점거리 편의가 지상 정확도에 미치는 영향 비교 연구 - 세가지 라인 스캐너를 대상으로 -)

  • Kim, Changjae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.363-371
    • /
    • 2014
  • Most space-borne optical scanning systems adopt linear arrayconfigurations. The well-knownthree different types of space-borne sensors arealong-track line scanner, across-track linescanner, and three line scanner. To acquire accurate location information of an object on the ground withthose sensors, the exterior and interior orientation parameters are critical factors for both of space-borne and airborne missions. Since the imaging geometry of sensors mightchange time to time due to thermal influence, vibration, and wind, it is very important to analyze the Interior Orientation Parameters (IOP) effects on the ground. The experiments based on synthetic datasets arecarried out while the focal length biases are changing. Also, both high and low altitudes of the imagingsensor were applied. In case with the along-track line scanner, the focal length bias caused errors along the scanline direction. In the other case with the across-track one, the focal length bias caused errors alongthe scan line and vertical directions. Lastly, vertical errors were observed in the case ofthree-line scanner. Those results from this study will be able to provide the guideline for developing new linearsensors, so as for improving the accuracy of laboratory or in-flight sensor calibrations.

Assessment of the Rock Strength using Borehole Acoustic Scanner (초음파 주사검층 방법을 이용한 암반강도 평가에 관한 연구)

  • Lee Kwangbae;Heo Seung;Song Young-Soo;Song Seungyup;Kim Haksoo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.4
    • /
    • pp.225-233
    • /
    • 2004
  • The purpose of this study is to provide the geo-technical information by assessment of the in-situ rock strength using the reflected wave energy and travel time data acquired by the borehole acoustic scanner. In order to compare and analyze the relationship between the uniaxial compressive strength and the reflected wave energy, the laboratory test and the borehole acoustic scanning were conducted for the set of specimens, such as mortar, concrete, and rock samples which have different rock type. Finally, we verified the applicability of the reflected wave energy acquired by the borehole acoustic scanner to quantitatively estimate the in-situ rock strength.