• 제목/요약/키워드: scanning source

검색결과 469건 처리시간 0.024초

패션머천다이저 환경탐색 형태와 정보매체 특성과의 관계에 관한 연구 (A Study on the Relationship between Environmental Scanning of Fashion Merchandisers and Characteristics of Information Sources)

  • 김성근;임남영
    • Journal of Information Technology Applications and Management
    • /
    • 제15권4호
    • /
    • pp.137-157
    • /
    • 2008
  • Fashion merchandiser profession is a highly information-intensive job. In fact, a merchandiser is to acquire a variety of information mainly from external environment and to analyze it in order to come to an informed decision. Despite a significant amount of past studies on environment scanning, their main concern was of managerial work. And, some fashion design studies have only touched the issue of information source in a descriptive tone. Here, we attempt to analyze empirically fashion merchandisers' environmental scanning activities. Our results can be stated as follows : 1) Though the quality of information source has a positive relationship with its use, the accessibility does not. 2) There is no significant difference between the use of relational source and the use of non-relational source. 3) Internet is being used more at the initial stage(opening) of information seeking than at the orientation and consolidation stage.

  • PDF

오픈소스 취약점 점검 도구 및 종합 보안 메트릭 설계를 통한 DevSecOps 구축방안 연구 (A Study on the Development of DevSecOps through the Combination of Open Source Vulnerability Scanning Tools and the Design of Security Metrics)

  • 최영해;노형준;조성윤;강한승;김동완;박수현;조민재;이주형
    • 정보보호학회논문지
    • /
    • 제33권4호
    • /
    • pp.699-707
    • /
    • 2023
  • DevSecOps는 DevOps의 짧은 개발과 운용주기에 대응하기 위해 DevOps의 운용절차에 보안절차를 추가한 개념이다. DevSecOps 구축 시 빠른 개발 및 배포 주기를 지원하면서 안정적으로 보안성을 제공하기 위해 여러 단계의 취약점 점검 절차가 고려되어야 한다. 각 점검 단계별 활용 가능한 여러 오픈소스 취약점 점검 도구들이 존재하고 있으나 도구들이 지원하는 기능이 다양하고 점검결과들이 상이해 통합 운용 시 보안성 수준 평가 및 정보의 중요도 파악에 어려움이 있다. 본 논문은 오픈소스를 활용한 DevSecOps 구축 시에 보안점검 단계별 활용 가능한 오픈소스 취약점 점검 도구의 조합과 점검결과에 대한 통합적인 보안메트릭 설계방안을 제안한다.

리얼 타임 리눅스 시스템 설계 (Real Time Linux System Design)

  • 이아리;홍선학
    • 디지털산업정보학회논문지
    • /
    • 제10권2호
    • /
    • pp.13-20
    • /
    • 2014
  • In this paper, we implemented the object scanning with nxtOSEK which is an open source platform. nxtOSEK consists of device driver of leJOS NXJ C/Assembly source code, TOPPERS/ATK(Automotive real time Kernel) and TOPPERS/JSP Real-Time Operating System source code that includes ARM7 specific porting part, and glue code make them work together. nxtOSEK can provide ANSI C by using GCC tool chain and C API and apply for real-time multi tasking features. We experimented the 3D scanning with ultra sonic and laser sensor which are made directly by laser module diode and experimented the measurement of scanning the object by knowing x, y, and z coordinates for every points that it scans. In this paper, the laser module is the dimension of $6{\times}10[mm]$ requiring 5volts/5[mW], and used the laser light of wavelength in the 650[nm] range. For detecting the object, we used the beacon detection algorithm and as the laser light swept the objects, the photodiode monitored the ambient light at interval of 10[ms] which is called a real time. We communicated the 3D scanning platform via bluetooth protocol with host platform and the results are displayed via DPlot graphic tool. And therefore we enhanced the functionality of the 3D scanner for identifying the image scanning with laser sensor modules compared to ultra sonic sensor.

Fabrication of Microcantilever Ultrasound Sensor and Its Application to the Scanning Laser Source Technique

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • 비파괴검사학회지
    • /
    • 제25권6호
    • /
    • pp.459-466
    • /
    • 2005
  • The scanning laser source (SLS) technique has been proposed recently as an effective way to investigate small surface-breaking defects, By monitoring the amplitude and frequency changes of the ultrasound generated as the SLS scans over a defect, the SLS technique has provided enhanced signal-to-noise performance compared to the traditional pitch-catch or pulse-echo ultrasonic methods, An extension of the SLS approach to map defects in microdevices is proposed by bringing both the generator and the receiver to the near-field scattering region of the defects, To facilitate near-field ultrasound measurement, silicon microcantilever probes are fabricated using microfabrication technique and their acoustical characteristics are investigated, Then, both the laser-generated ultrasonic source and the microcantilever probe are used to monitor near-field scattering by a surface-breaking defect.

The Scanning Laser Source Technique for Detection of Surface-Breaking and Subsurface Defect

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • 비파괴검사학회지
    • /
    • 제27권3호
    • /
    • pp.246-254
    • /
    • 2007
  • The scanning laser source (SLS) technique is a promising new laser ultrasonic tool for the detection of small surface-breaking defects. The SLS approach is based on monitoring the changes in laser-generated ultrasound as a laser source is scanned over a defect. Changes in amplitude and frequency content are observed for ultrasound generated by the laser over uniform and defective areas. The SLS technique uses a point or a short line-focused high-power laser beam which is swept across the test specimen surface and passes over surface-breaking or subsurface flaws. The ultrasonic signal that arrives at the Rayleigh wave speed is monitored as the SLS is scanned. It is found that the amplitude and frequency of the measured ultrasonic signal have specific variations when the laser source approaches, passes over and moves behind the defect. In this paper, the setup for SLS experiments with full B-scan capability is described and SLS signatures from small surface-breaking and subsurface flaws are discussed using a point or short line focused laser source.

뇌파/뇌자도 전류원 국지화의 공간분해능 향상을 위한 독립성분분석 기반의 부분공간 탐색 알고리즘 (An ICA-Based Subspace Scanning Algorithm to Enhance Spatial Resolution of EEG/MEG Source Localization)

  • 정영진;권기운;임창환
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권6호
    • /
    • pp.456-463
    • /
    • 2010
  • In the present study, we proposed a new subspace scanning algorithm to enhance the spatial resolution of electroencephalography (EEG) and magnetoencephalography(MEG) source localization. Subspace scanning algorithms, represented by the multiple signal classification (MUSIC) algorithm and the first principal vector (FINE) algorithm, have been widely used to localize asynchronous multiple dipolar sources in human cerebral cortex. The conventional MUSIC algorithm used principal component analysis (PCA) to extract the noise vector subspace, thereby having difficulty in discriminating two or more closely-spaced cortical sources. The FINE algorithm addressed the problem by using only a part of the noise vector subspace, but there was no golden rule to determine the number of noise vectors. In the present work, we estimated a non-orthogonal signal vector set using independent component analysis (ICA) instead of using PCA and performed the source scanning process in the signal vector subspace, not in the noise vector subspace. Realistic 2D and 3D computer simulations, which compared the spatial resolutions of various algorithms under different noise levels, showed that the proposed ICA-MUSIC algorithm has the highest spatial resolution, suggesting that it can be a useful tool for practical EEG/MEG source localization.

배관 검사용 Radiometric Scanning System 제작 및 시험 (Development of Radiometric Scanning System for the Evaluation of the Pipeline)

  • 김용균;홍석붕;정종은;이윤호;정용하;이정기
    • 비파괴검사학회지
    • /
    • 제22권5호
    • /
    • pp.474-482
    • /
    • 2002
  • 필름을 사용하지 않는 방사선투과검사 시스템인 1차원 Radiometric scanning system을 개발하여 부식 및 침적물이 있는 배관의 두께평가에 적용해 보았다. 개발된 시스템은 단일 방사성 동위원소에서 나오는 방사선을 선형으로 접속하여 시험체를 투과시킨 방사선을 한개의 섬광형 검출기언 BGO를 사용하여 검출하는 single source-single detector alignment system을 제어하는 기계주사 시스템과 제어 프로그램을 개발하였다. 개발된 시스템의 성능을 GEMANT4 프로그램을 사용하여 예측하여 보았다. 그리고, 인공결함을 제작하여 넣은 시편과 두께 변화를 준 시편에 적용하여 실제 성능을 평가하였다. 이 시스템은 방사성 동위원소를 이용하여 배관의 부식과 침적물에 의한 두께 변화에 대하여 실시간으로 필름을 사용하지 않고 평가할 수 있는 가능성을 알 수 있었다.

가시광 영역의 저간섭성 광원을 이용한 마이겔슨 간섭계 (Low-coherence non-scanning michelson interferometry using visible broadband light source)

  • 송민호;이병호
    • 전자공학회논문지A
    • /
    • 제33A권10호
    • /
    • pp.160-167
    • /
    • 1996
  • A new pathlength deviation detection technique which is composed of michelson interferometer is described and verified experimentally. The technique uses a sub-threshold biased visible laser diode of 20$\mu$m coherence length as a low-coherent light source. And for zeroth-order fringe(which is the largest among fringes) identification we used a piezoelectric transducer with a large modulation smplitude, which enables without the need of constant velocity scanning, to distinguish reflection surfaces separated by more than 10$\mu$m with a resolution of less than half-wavelength.

  • PDF

Scientific and Engineering Applications of Full-field Swept-source Optical Coherence Tomography

  • Mehta, Dalip Singh;Anna, Tulsi;Shakher, Chandra
    • Journal of the Optical Society of Korea
    • /
    • 제13권3호
    • /
    • pp.341-348
    • /
    • 2009
  • We report the development of full-field swept-source optical coherence tomography (SS-OCT) in the wavelength range of 815-870 nm using a unique combination of super-luminescent diode (SLD) as broad-band light source and acousto-optic tunable filter (AOTF) as a frequency-scanning device. Some new applications of full-field SS-OCT in forensic sciences and engineering materials have been demonstrated. Results of simultaneous topography and tomography of latent fingerprints, silicon microelectronic circuits and composite materials are presented. The main advantages of the present system are completely non-mechanical scanning, wide-field, compact and low-cost.

전자선에서 Virtual Source Distance의 위치 결정 (Determination of the Virtual Focus Position for Electron Beam with Air Scanning)

  • 권경태;윤화룡;박광호;김정만
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.89-93
    • /
    • 1994
  • Authors have measured virtual source distance of electron beam from CL/1800 medical linear accelerator, with newly designed method. Beam scanning was performed with the direction of beam axis in the air. Compared results between this study and well established in phantom measurement shows good agreement with in experimental error. And we have found that build-up cap plays very important role in air measurement because of charge build up. The method of in-air measurement of virtual source distance is very easy to set-up and generate accurate results.

  • PDF