• 제목/요약/키워드: screw connection

검색결과 117건 처리시간 0.022초

Correlation between microleakage and screw loosening at implant-abutment connection

  • Sahin, Cem;Ayyildiz, Simel
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.35-38
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS. Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titanium) with different geometries were connected to its own implant fixture. All the abutments were tightened with a standard torque value then the composition was connected to the modified fluid filtration system. After the measurements of leakage removal torque values were re-measured. Kruskal-wallis test was performed for non-parametric and one-way ANOVA was performed for parametric data. The correlation was evaluated using Spearman Correlation Test (${\alpha}=0.05$). RESULTS. Significantly higher microleakage was found at the connection of implant-internal hex zirconium abutment. Observed mean torque value loss was also significantly higher than other connection geometries. Spearman tests revealed a significant correlation between microleakage and screw loosening. CONCLUSION. Microleakage may provoke screw loosening. Removing torque values rationally decrease with the increase of microleakage.

FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.

나사를 이용한 기구물과 인쇄회로기판 연결이 전원단 잡음 감소에 미치는 영향 분석 (Investigation of Power Bus Decoupling by the Screw Connection of the PCB to Chassis)

  • 권덕규;이신영;이해영;이재욱;배승민
    • 한국전자파학회논문지
    • /
    • 제13권10호
    • /
    • pp.1040-1047
    • /
    • 2002
  • 본 논문에서는 인쇄회로기판을 기구물에 기계적으로 고정시키고, 전기적으로 접지시키기 위해 사용되는 스크류 연결이 파워버스 잡음에 미치는 영향을 분석하였다. 스크류는 인쇄회로기판과 기구물을 연결하기 위하여 파워버스를 관통하게 되며, 이는 파워버스 잡음에 영향을 미치게 된다. 이러한 스크류 연결의 효과를 확인하기 위하여 스크류가 없는 기판과 5개의 스크류를 사용하여 인쇄회로기판과 기구물의 간격을 0.5 mm로 설정한 경우를 비교하였다. 비교 결과 제안된 방법은 스크류가 없는 경우에 비해 0.1 GHz - l GHz의 주파수 대역에서 5 dB 이상 잡음 특성이 개선되는 것을 확인하였다. 또한 신호선이 존재하는 4층 인쇄회로기판에 스크류를 사용한 경우 600 MHz까지 신호의 특성이 개선되는 것을 확인하였다. 본 연구는 고속 회로 및 기구물 설계에 유용하게 활용될 수 있을 것으로 기대된다.

임플랜트-지대주의 연결방법에 따른 임플랜트 보철의 유한요소 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO CONNECTION TYPES OF IMPLANT-ABUTMENT)

  • 허진경;계기성;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.544-561
    • /
    • 2005
  • Purpose : This study was to assess the loading distributing characteristics of implant systems with internal connection or external connection under vertical and inclined loading using finite element analysis. Materials and methods : Two finite element models were designed according to type of internal connection or external connection The crown for mandibular first molar was made using cemented abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the centric cusp tip in a 15$^{\circ}$ inward inclined direction (loading condition B), or 200N at the centric cusp tip in a 30$^{\circ}$ outward inclined direction (loading condition C) respectively. Von Mises stresses were recorded and compared in the supporting bone, fixture, abutment and abutment screw. Results : 1. In comparison with the whole stress or the model 1 and model 2, the stress pattern was shown through th contact of the abutment and the implant fixture in the model 1, while the stress pattern was shown through the abutment screw mainly in the model 2. 2. Without regard to the loading condition, greater stress was taken at the cortical bone, and lower stress was taken at the cancellous bone. The stress taken at the cortical bone was greater at the model 1 than at the model 2, but the stress taken at the cortical bone was much less than the stress taken at the abutment, the implant fixture, and the abutment screw in case of both model 1 and model 2. 3. Without regard to the loading condition, the stress pattern of the abutment was greater at the model 1 than at the model 2. 4. In comparison with the stress distribution of model 1 and model 2, the maximum stress was taken at the abutment in the model 1. while the maximum stress was taken at the abutment screw in the model 2. 5. The magnitude of the maximum stress taken at the supporting bone, the implant fixture, the abutment, and the abutment screw was greater in the order of loading condition A, B and C. Conclusion : The stress distribution pattern of the internal connection system was mostly distributed widely to the lower part along the inner surface of the implant fixture contacting the abutment core through its contact portion because of the intimate contact of the abutment and the implant fixture and so the less stress was taken at the abutment screw, while the abutment screw can be the weakest portion clinically because the greater stress was taken at the abutment screw in case of the external connection system, and therefore the further clinical study about this problem is needed.

Screw loosening and changes in removal torque relative to abutment screw length in a dental implant with external abutment connection after oblique cyclic loading

  • Lee, Joo-Hee;Cha, Hyun-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권6호
    • /
    • pp.415-421
    • /
    • 2018
  • PURPOSE. This study investigated the effects of abutment screw lengths on screw loosening and removal torque in external connection implants after oblique cyclic loading. MATERIALS AND METHODS. External connection implants were secured with abutment screws to straight abutments. The abutment-implant assemblies were classified into seven groups based on the abutment screw length, with each group consisting of five assemblies. A cyclic load of 300 N was applied at a $30^{\circ}$ angle to the loading axis until one million cycles were achieved. Removal torque values (RTVs) before and after loading, and RTV differences were evaluated. The measured values were analyzed using repeated measures of analysis of variance with the Student-Newman-Keuls multiple comparisons. RESULTS. All assemblies survived the oblique cyclic loading test without screw loosening. There was a significant decrease in the RTVs throughout the observed abutment screw lengths when the abutment-implant assemblies were loaded repeatedly (P<.001). However, the abutment screw length did not show significant difference on the RTVs before and after the experiment when the abutment screw length ranged from 1.4 to 3.8 mm (P=.647). CONCLUSION. Within the limit of this experiment, our results indicate that the abutment screw length did not significantly affect RTV differences after oblique cyclic loading when a minimum length of 1.4 mm (3.5 threads) was engaged. These findings suggest that short abutment screws may yield stable clinical outcomes comparable to long screws in terms of load resistance.

다른 연결 시스템을 갖는 임플랜트 상부 구조물에서 조임술식에 따른 지대주 나사의 풀림 토크값에 대한 연구 (Removal Torque Values of Retaining Screws Tightened to Implant-Supported Prosthesis with Different Connection Systems by Various Tightening Technique)

  • 김동욱;최유성;조인호
    • 구강회복응용과학지
    • /
    • 제27권4호
    • /
    • pp.343-358
    • /
    • 2011
  • 임플랜트 치료가 보편화되고, 다양한 형태와 재료의 상부 구조물이 보급되었다. 그리고 실패에 대한 보고도 다양하며, 그 중 지대나사의 풀림현상이 가장 흔하다고 지적되고 있다. 본 연구는 외부연결구조와 내부연결구조 임플랜트에 의해 지지되는 상부 구조물을 나사로 연결할 때, 세 가지 나사조임순서와 두 가지 나사조임방법에 따른 나사의 풀림 토크값을 비교하여 나사조임순서와 나사조임방법이 서로 다른 연결구조에 따라 나사풀림현상에 미치는 영향을 알아보고자 하였다. 완전 무치악 하악모형을 자가중합형 아크릴릭 레진으로 제작하고 이공간 부위에 중심간 거리가 약 15 mm 되도록 네 개의 임플랜트 고정체 유사체를 고정한 후 바 타입으로 납형 형성하여 상부 구조물을 주조 제작하였다. 상부 구조물과 정확한 적합이 되는 주모형을 제작한 후 연결 인상법으로 외부연결구조, 내부연결구조를 가지는 연구모형을 각각 5개씩 제작하였다. 각 모형에서 각 나사의 풀림 토크값을 가장 왼쪽에 조여지는 나사를 1번 나사로 하고 가장 오른쪽의 나사를 4번 나사로 명명하였다. 먼저, 나사조임순서의 영향을 알아보기 위해 1-2-3-4, 2-3-1-4, 2-4-3-1의 순서로 15 Ncm의 힘으로 조이고, 다시 같은 순서로 최종 조임토크값인 30 Ncm까지 조인 후 (2-step 방법) 각 나사의 풀림 토크값을 측정하였다. 또한 나사조임방법의 영향을 알아보기 위해 2-3-1-4의 순서로 한 번에 최종 조임토크값인 30 Ncm까지 조인 후 (1-step 방법) 각 나사의 풀림 토크값을 측정하여 같은 순서 (2-3-1-4)의 2-step 방법과 비교하였다. 세 가지 나사조임순서에 따른 나사의 풀림 토크값은 외부연결구조에서 2-3-1-4군이 2-4-3-1군보다 유의하게 낮았다 (p<0.05). 그리고 내부연결구조에서도 2-3-1-4군이 2-4-3-1군과 1-2-3-4군보다 유의하게 낮았다 (p<0.05). 또한 나사조임순서와 무관하게 몇 번째 조여진 나사인지에 따른 풀림 토크값을 비교해 본 결과, 외부연결구조에서는 처음에 조여진 나사가 두 번째 조여진 나사보다 유의하게 높았으나 (p<0.05), 내부연결구조에서는 처음에 조여진 나사에서부터 마지막에 조여진 나사 간에 차이가 없었다. 그리고 두 가지 나사조임방법 간에는 외부연결구조와 내부연결구조 모두에서 통계학적으로 유의한 차이가 없었다. 연결구조에 대한 비교에서 외부연결구조와 내부연결구조의 풀림 토크값은 각각 16.27 Ncm, 14.25 Ncm 였으며, 통계적으로 유의한 차이가 나타났다 (p<0.05). 다수 임플랜트에 의해 지지되는 상부 구조물을 나사로 연결할 때, 나사조임순서에 따라 차이가 있었으며, 가운데부터 조인 경우에서 풀림 토크값이 낮았고, 연결구조 간에도 차이가 있었다. 풀림 토크값에 미치는 요인에 대해 좀 더 상세히 분석할 필요가 있으며, 하중 조건에서의 부가적인 연구가 필요할 것으로 사료된다.

내측 연결 임플란트에서 지대주 내부길이가 나사 풀림에 미치는 영향 (Influence of internal connection length on screw loosening in internal connection implants)

  • 김지선;박영범;최현민;김성태;김현철;김선재;문홍석;이재훈
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.251-257
    • /
    • 2017
  • 목적:본 연구에서는 long internal connection 형태의 임플란트 지대주를 내부 연결 길이에 변화를 주어 임플란트-지대주 결합부의 안정성을 비교 평가해 보고자 하였다. 재료 및 방법: Long internal connection의 임플란트(Replus system, $4.7{\times}11.5mm$)를 각각 지대주의 길이에 따라 4개의 군(1, 2, 3, 4 mm 군)으로 나누었고 총 20개의 시편을 사용하였다. 시편을 레진에 매몰하여 고정시키고 100 N의 힘으로 임플란트 장축에 대해 30도의 각도에서 $1.0{\times}10^6$ 번의 반복하중을 가한 후 하중 전 후의 풀림회전력의 차이를 계산하여 95% 유의수준에서 Kruskal-Wallis 검정 방법을 통해 통계 분석하였다. 결과:지대주 내부 길이에 따른 풀림 회전력의 통계적 유의성은 나타나지 않았으며 (P > .05) 어떤 시편에서도 완전한 나사 풀림이나 나사 파절은 관찰되지 않았다. 결론: 내측 연결 임플란트에서 지대주 내부길이에 따른 나사 풀림의 정도는 차이가 나지 않았다.

Analytical investigation of thin steel plate shear walls with screwed infill plate

  • Vatansever, Cuneyt;Berman, Jeffrey W.
    • Steel and Composite Structures
    • /
    • 제19권5호
    • /
    • pp.1145-1165
    • /
    • 2015
  • A behavior model for screw connections is developed to provide a better representation of the nonlinear response of thin steel plate shear walls (TSPSWs) with infill plates attached to the boundary frame members via self-drilling screws. This analytical representation is based on the load-bearing deformation relationship between the infill plate and the screw threads. The model can be easily implemented in strip models of TSPSWs where the tension field action of the infill plates is represented by a series of parallel discrete tension-only strips. Previously reported experimental results from tests of two different TSPSWs are used to provide experimental validation of the modeling approach. The beam-to-column connection behavior was also included in the analyses using a four parameter rotational spring model that was calibrated to a test of an identical frame as used for the TSPSW specimens but without the infill plates. The complete TSPSW models consisting of strips representing the infill plates, zero length elements representing the load-bearing deformation response of the screw connection at each end of the strips and the four parameter spring model at each beam-to-column connection are shown to have good agreement with the experimental results. The resulting models should enable design and analysis of TSPSWs for both new construction and retrofit of existing buildings.

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).

지대주 나사 조임 토크가 맞춤형 지대주 임플란트 시스템의 연결부 안정성에 미치는 영향: 3차원 유한 요소 해석 (Effect of tightening torque on the connection stability of a custom-abutment implant system: 3D finite element analysis)

  • 홍민호
    • 대한치과기공학회지
    • /
    • 제43권3호
    • /
    • pp.99-105
    • /
    • 2021
  • Purpose: This study aims to examine the stress distribution effect of tightening torques of different abutment screws in a custom-abutment implant system on the abutment-fixture connection interface stability using finite element analysis. Methods: The custom-abutment implant system structures used in this study were designed using CATIA program. It was presumed that the abutment screws with a tightening torque of 10, 20, and 30 N·cm fixed the abutment and fixture. Furthermore, two external loadings, vertical loading and oblique loading, were applied. Results: When the screw tightening torque was 10 N·cm, the maximum stress value of the abutment screw was 287.2 MPa that is equivalent to 33% of Ti-6Al-4V yield strength. When the tightening torque was 20 N·cm, the maximum stress value of the abutment screw was 573.9 MPa that is equivalent to 65% of Ti-6Al-4V yield strength. When the tightening torque was 30 N·cm, the maximum stress value of the abutment screw was 859.6 MPa that is similar to the Ti-6Al-4V yield strength. Conclusion: As the screw preload rose when applying each tightening torque to the custom-abutment implant system, the equivalent stress increased. It was found that the tightening torque of the abutment influenced the abutment-fixture connection interface stability. The analysis results indicate that a custom-abutment implant system should closely consider the optimal tightening torque according to clinical functional loads.