• 제목/요약/키워드: seismic margin

검색결과 118건 처리시간 0.024초

Bayesian-based seismic margin assessment approach: Application to research reactor

  • Kwag, Shinyoung;Oh, Jinho;Lee, Jong-Min;Ryu, Jeong-Soo
    • Earthquakes and Structures
    • /
    • 제12권6호
    • /
    • pp.653-663
    • /
    • 2017
  • A seismic margin assessment evaluates how much margin exists for the system under beyond design basis earthquake events. Specifically, the seismic margin for the entire system is evaluated by utilizing a systems analysis based on the sub-system and component seismic fragility data. Each seismic fragility curve is obtained by using empirical, experimental, and/or numerical simulation data. The systems analysis is generally performed by employing a fault tree analysis. However, the current practice has clear limitations in that it cannot deal with the uncertainties of basic components and accommodate the newly observed data. Therefore, in this paper, we present a Bayesian-based seismic margin assessment that is conducted using seismic fragility data and fault tree analysis including Bayesian inference. This proposed approach is first applied to the pooltype nuclear research reactor system for the quantitative evaluation of the seismic margin. The results show that the applied approach can allow updating by considering the newly available data/information at any level of the fault tree, and can identify critical scenarios modified due to new information. Also, given the seismic hazard information, this approach is further extended to the real-time risk evaluation. Thus, the proposed approach can finally be expected to solve the fundamental restrictions of the current method.

내진여유도평가법에 근거한 기존 강구조물의 내진성능평가 (Evaluation of Seismic Margin of Existing Steel Structure Based on Seismic Margin Assessment)

  • 황규호;송정국;강선구;서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.239-249
    • /
    • 2002
  • The Turbine Building of nuclear power plant is classified as non safety-related structure. During the operation, there may be possibility the original licensing basis would be changed, which makes non safety-related structure safety-related. Such a change in regulation requires utility to perform seismic qualification for the existing structure and their facilities. Thus it is meaningful to evaluate seismic margin of the existing non-qualified building structure. In addition, in this paper it is shown that a modification to the structure can enhance their seismic capacity.

  • PDF

Evolution of the eastern margin of Korea: constraints on the opening of the East Sea (Japan Sea)

  • Kim, Han-Joon;Jou, Hyeong-Tae;Suk, Bong-Chool
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 특별 심포지엄 논문집
    • /
    • pp.73-83
    • /
    • 2007
  • We interpreted marine seismic profiles in conjunction with swath bathymetric and magnetic data to investigate rifting to breakup processes at the eastern Korean margin that led to the separation of the southwestern Japan Arc. Analysis of rift fault patterns suggests that rifting at the Korean margin was primarily controlled by normal faulting resulting from extension rather than strike-slip deformation. Two extension directions of E-W and NW-SE for rifting are recognized. We interpret that the E-W direction represents initial rifting at the inner margin and the NW-SE direction probably represents the extension in response to tensional tectonics associated with the subduction of the Pacific Plate in the NW direction. No significant volcanism was involved in rifting. In contrast, the inception of sea floor spreading documents a pronounced volcanic phase which appears to reflect asthenospheric upwelling as well as rift-induced convection particularly in the narrow southern margin. We suggest that structural and igneous evolution of the Korean margin, although it is in a back-arc setting, can be explained by the processes occurring at the passive continental margin with magmatism influenced by asthenospheric upwelling.

  • PDF

내진여유도 평가를 위한 부석기준지진동(RLGM) 평가 연구 (A Study on Review-Level Ground Motion For Seismic Margin Assessment)

  • 연관희;이종림
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.97-104
    • /
    • 2000
  • Evaluating a Review-Level Ground Motion is a key to efficiently perform Seismic Margin Assessment of nuclear power plants whose purpose is to determine a ground motion level for which a plant has high-confidence-of-a-low-probability of seismic-induced core damage and to identify any weaker-link components. In this study a method to obtain RLGMs is reviewed which is recommended by Electric Power Research Institute and implemented to be applied to Limerick site in eastern and central U. S as a case study. This method provides reasonable and site-specific RLGMs as minimum required plant HCLPF for SMA that meet a target mean seismic core-damage frequency based on seismic hazard results and generic values of uncertainty and randomness parameters of the core-damage fragility curves. In addition high-frequency RLGM is justifiably modified to reflect the increased seismic capacity of high-frequency components and spatial variation and incoherence of input ground motion on a basemat of large structures by establishing a method to obtain high0-frequency reduction factors according to EPRI guidelines.

  • PDF

콘크리트 옹벽의 지진여유도 평가 (Seismic Margin Assessment of Concrete Retaining Walls)

  • 박두희;백종민;박인준;황경민;장정범
    • 한국지반환경공학회 논문집
    • /
    • 제20권7호
    • /
    • pp.5-10
    • /
    • 2019
  • 최근 발생한 경주지진('16.9.12., $M_L=5.8$) 및 포항지진('17.11.15., $M_L=5.4$)에서 국내의 설계지반운동 수준을 초과하는 진동이 관측되었으며 이를 계기로 설계지반운동이 일부 내진설계지침서에서 개정되었다. 설계지반운동이 조정되면 관련된 모든 시설물의 내진성능을 재평가해야 하며 이를 위해서는 막대한 시간과 비용이 소요된다. 본 연구에서는 일차적으로 조정된 설계지반운동기준에 대한 기설된 콘크리트 옹벽의 내진성능 확보 여부를 평가하였으며 이차적으로 콘크리트 옹벽의 지진여유도를 평가하였다. 변전소 주변에 기설된 콘크리트 옹벽 단면과 지반주상도를 사용하였으며 지진에 대한 안전율은 유사정적해석법을 사용하여 계산하였다. 평가에 사용된 모든 옹벽은 조정된 설계지반운동에 대해서 충분한 성능을 확보하고 있는 것으로 나타났다. 나아가 옹벽의 지진여유도를 평가하기 위하여 기준 안전율을 만족하지 못하는 임계가속도를 계산하였다. 임계가속도는 0.36g~0.8g 범위로 설계지반운동을 크게 상회하며 콘크리트 옹벽의 지진여유도는 매우 큰 것으로 분석되었다. 따라서 추후 설계지반운동이 0.3g 이상으로 상향조정되어도 옹벽의 전면적인 재평가는 불필요할 것으로 판단된다.

원전 구조물의 내진성능 평가 방법론 고찰 (Seismic Performance Evaluation Methodology for Nuclear Power Plants)

  • 안호준;김유석;공정식;최영진;최세운;이민석
    • 한국압력기기공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.32-40
    • /
    • 2018
  • Since 2000, the frequency of earthquakes beyond the 5.0 magnitude quake has been increasing in the Korean peninsula. For instance, the 5.0-magnitude earthquake in Baekryong-do in 2003 has occurred, and recent earthquake with Gyeongju(2016) and Pohang(2017) measured respectively magnitude of 5.2 and 5.8 on the Richter scale. As results, the public concern and anxiety about earthquakes are increasing, and therefore it is necessarily required for social infrastructure to reinforce seismic design and energy production facilities directly related to the national economy and security. This study represents the analysis of seismic performance evaluation methodology such as Seismic Margin Assessment (SMA), Seismic Probabilistic Risk Assessment (SPRA), High Confidence Low Probability Failure (HCLPF) in nuclear power plants in order to develop optimal seismic performance improvement. Current methodologies to evaluate nuclear power plants are also addressed. Through review of the nuclear structure evaluation past and current trend, it contributes to be the basis for the improvement of evaluation techniques on the next generation of nuclear power plants.

Seismic performance of a resilient low-damage base isolation system under combined vertical and horizontal excitations

  • Farsangi, Ehsan Noroozinejad;Tasnimi, Abbas Ali;Yang, T.Y.;Takewaki, Izuru;Mohammadhasani, Mohammad
    • Smart Structures and Systems
    • /
    • 제22권4호
    • /
    • pp.383-397
    • /
    • 2018
  • Traditional base isolation systems focus on isolating the seismic response of a structure in the horizontal direction. However, in regions where the vertical earthquake excitation is significant (such as near-fault region), a traditional base-isolated building exhibits a significant vertical vibration. To eliminate this shortcoming, a rocking-isolated system named Telescopic Column (TC) is proposed in this paper. Detailed rocking and isolation mechanism of the TC system is presented. The seismic performance of the TC is compared with the traditional elastomeric bearing (EB) and friction pendulum (FP) base-isolated systems. A 4-storey reinforced concrete moment-resisting frame (RC-MRF) is selected as the reference superstructure. The seismic response of the reference superstructure in terms of column axial forces, base shears, floor accelerations, inter-storey drift ratios (IDR) and collapse margin ratios (CMRs) are evaluated using OpenSees. The results of the nonlinear dynamic analysis subjected to multi-directional earthquake excitations show that the superstructure equipped with the newly proposed TC is more resilient and exhibits a superior response with higher margin of safety against collapse when compared with the same superstructure with the traditional base-isolation (BI) system.

면진된 KALIMER 원자로 구조물의 내진설계 및 지진해석 (Seismic Design and Analysis of Seismically Isolated KALIMER Reactor Structures)

  • 이형연
    • 한국지진공학회논문집
    • /
    • 제3권1호
    • /
    • pp.75-92
    • /
    • 1999
  • 본 연구에서는 현재 국내에서 면진설계를 적용하여 개발중인 KALIMER(Korea Advanced Llquid Metal Reactor) 액체금속로에 대한 내진설계 및 지진해석을 위하여 핵심구조물인 원자로구조물에 대한 단순 지진해석모델을 개발하였다 이를 이용하여 면진설계의 경우와 비면진 설계의 경우에 대한 동특성분석과 시간이력 지진해석을 수행하여 비교평가하였다. 또한 ASME 설계코드에 따른 응력한계요건을 검토하기 위하여 등가 지진응력해석을 수행하고 이로부터 내진여유도를 계산하였다 지진안전성에 대한 하나의 지표로서 원자로 구조물이 견딜수 있는 최대지진하중을 결정하기 위한 한계지진하중(Limit seismic load)을 저의하였다 지진해석결과 면진된 KALIMER 원자로구조믈은 비면진된 경우에 비하여 가속도응답과 구조물간의 상대변위응답이 현저히 감소하였고 충분한 내진여유도로 인하여 한계지진하중이 0.8g로 나타났다.

  • PDF

벽체-감쇠 복합시스템을 갖는 건물의 지진취약도 분석 (Seismic Fragility Analysis of Buildings With Combined Shear Wall-Damper System)

  • 라지불 이슬람;수딥타 차크라보르티;공병진;김두기
    • 한국지진공학회논문집
    • /
    • 제27권2호
    • /
    • pp.91-99
    • /
    • 2023
  • Structural vibration induced by earthquake hazards is one of the most significant concerns in structure performance-based design. Structural hazards evoked from seismic events must be properly identified to make buildings resilient enough to withstand extreme earthquake loadings. To investigate the effects of combined earthquake-resistant systems, shear walls and five types of dampers are incorporated in nineteen structural models by altering their arrangements. All the building models were developed as per ACI 318-14 and ASCE 7-16. Seismic fragility curves were developed from the incremental dynamic analyses (IDA) performed by using seven sets of ground motions, and eventually, by following FEMA P695 provisions, the collapse margin ratio (CMR) was computed from the collapse curves. It is evident from the results that the seismic performance of the proposed combined shear wall-damper system is significantly better than the models equipped with shear walls only. The scrutinized dual seismic resisting system is expected to be applied practically to ensure a multi-level shield for tall structures in high seismic risk zones.

고진동수 지진동에 대한 원전 기기의 지진취약도 분석 (Seismic Fragility Analysis of NPP Components for High Frequency Ground Motions)

  • 최인길;서정문;전영선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.110-117
    • /
    • 2003
  • The result of recent seismic hazard analysis indicates that the ground motion response spectra for Korean nuclear power plant site have relatively large high frequency acceleration contents. In the ordinary seismic fragility analysis of nuclear power plant structures and equipments, the safety margin of design ground response spectrum is directly used as a response spectrum shape factor. The effects of input response spectrum shape on the floor response spectrum were investigated by performing the direct generation of floor response spectrum from the ground response spectrum. The safety margin included in the design ground response spectrum should be considered as a floor response spectrum shape factor for the seismic fragility analysis of the equipments located in a building.

  • PDF