• Title/Summary/Keyword: separator

Search Result 737, Processing Time 0.029 seconds

Study on the Separation Performance of a Tray-type Paddy Separator (트레이형 현립분리기의 분리성능에 관한 연구)

  • 정창주
    • Journal of Biosystems Engineering
    • /
    • v.5 no.1
    • /
    • pp.43-50
    • /
    • 1980
  • The milling plants in Korea have been generally used the paddy-separator that operated in accordance with the principle of sieving action. This type of paddy separator was considered as inefficient, especially in relation to the new high-yielding varieties which have different size characteristics within their varieties and also as compared to traditional varieties. With the installation of modern paddy separator it may be possible to increase the overall milling system efficiency and to reduce the grain loss. This study was intended to identify and define important parameters required for assessing the separation performance of a tray-type paddy separator and to determine the optimum conditions of the inclination of separator-table. The results of the study were summarized as follows : (1) Separation performance can be given by use of many parameters found from the measurement of separator outputs. such as upper-tail recovery $(\varepsilon)$, purity of upper-tail $(\gamma)$ , separation recovery of brown rice $(\alpha)$, separation recovery paddy $(\beta)$, and efficiency of separator $(\epsilon)$, Among these para-meters , $\varepsilon$, $\gamma$, $\alpha$ and $\beta$, were designated , respectively, their independent properties of the paddy separator. In addition, their modes of variation due to a varied inclination of the separation table did not indicated in the same direction . However, the efficiency of separator had an advantage to indicate the overall characteristics of the separator performance with a clear optimum inclination condition of the separator table. (2) The optimum feed rate and maximum efficiency of the separator did not occur at the identical inclination of the separator table. Thus, for its practical operation it is necessary to compromise between the qualitative and quantitative performances of the separator. (3) The optimum setting of the separator table tested in the study showed to occur at its inclination of approximately $26^\circ<$/TEX> for the front and $8^\circ<$/TEX> for lateral.

  • PDF

Electrochemical and Safety Performances of Polyimide Nano fiber-based Nonwoven Separators for Li-ion Batteries

  • Kim, Yeon-Joo;Lee, Sang-Min;Kim, Seok Hong;Kim, Hyun-Soo
    • Journal of Electrochemical Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.26-33
    • /
    • 2015
  • In this study, cell performance and thermal stability of lithium-ion cells with a polyimide (PI) separator are investigated. In comparison to conventional polyethylene (PE) separator, the PI separator exhibits distinct advantage in microporous structure, leading to superior reliability of the cell. The cells with PI separator exhibit good cell performances as same as the cells with PE separator, but their reliability was superior to the cell with PE separator. Especially in the hot-box test at 150 and 180℃, PI separator showed a contraction percentage close to 0% at 150℃, while the PE separator showed a contraction percentage greater than 10% in both width and length. Therefore, the PI separator can be the promising candidate for separators of the next generation of lithium-ion battery.

Development of Physical Treatment Technology for Stall Wastewater

  • Oh, In-Hwan;Park, Jeung-Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.728-736
    • /
    • 1996
  • Solid/Liquid(S/L) separation is crucial for biological treatment of animal wastewater. Liquid portion from S/L separation has less BOD-load and proper post-strip treatment can be obtained . Screen or declined sieve was normally used to separate the solid parts. For better separating efficiency a vibration and a cylindrical separator were constructed and tested. The results are summarized as follows : Solids removal efficiency and moisture content of separated solid were 15-26% and 85-88%, respectively for the vibration separator. For the cylindrical separator, solid removal efficiency and moisture content of solid were 16-39% and 86-89% , respectively. The greatest amount of drymatter was obtained when operating vibration separator with 10。 inclination and 100% vibrating power. For the cylindrical separator maximum efficiency was obtained with 40rpm and 19 inclination . The vibration and the cylindrical separator have shown 21% and 26% in BOD removal, respectively. These two types of separator were proved to be applicable methods for animal wastewater separation.

  • PDF

Conceptual Design of Sandglass-like Separator for Immobilized Anionic Radionuclides Using Particle Tracking Based on Computational Fluid Dynamics

  • Park, Tae-Jin;Choi, Young-Chul;Ham, Jiwoong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.3
    • /
    • pp.363-372
    • /
    • 2020
  • Anionic radionuclides pose one of the highest risks to the long-term safety assessments of disposal repositories. Therefore, techniques to immobilize and separate such anionic radionuclides are of crucial importance from the viewpoints of safety and waste volume reduction. The main objective of this study is to design a separator with minimum pressure disturbance, based on the concept of a conventional cyclone separator. We hypothesize that the anionic radionuclides can be immobilized onto a nanomaterial-based substrate and that the particles generated in the process can flow via water. These particles are denser than water; hence, they can be trapped within the cyclone-type separator because of its design. We conducted particle tracking analysis using computational fluid dynamics (CFD) for the conventional cyclone separator and studied the effects due to the morphology of the separator. The proposed sandglass-like design of the separator shows promising results (i.e., only one out of 10,000 particles escaped to the outlet from the separation zone). To validate the design, we manufactured a laboratory-scale prototype separator and tested it for iron particles; the efficiency was ca. 99%. Furthermore, using an additional magnetic effect with the separator, we could effectively separate particles with ~100% efficiency. The proposed sandglass-like separator can thus be used for effective separation and recovery of immobilized anionic radionuclides.

Development of cryogenic liquid-vapor separator and liquid-level meter operating under high pressure condition (고압 상황에서 작동되는 극저온 기액 분리기와 액체 계면 측정기의 개발)

  • Lee, Cheon-Kyu;Hwang, Gyu-Wan;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.51-55
    • /
    • 2011
  • In this study, the liquid-vapor (L-V) separator equipped with liquid-level meter is developed. In the developed L-V separator, the flange is designed to be attachable so that the separator can be flexibly applied under any cases where the volumetric of L-V separator is varied by the system requirement. The leak-tightness between the attachable flange and the chamber is experimentally confirmed with the use of double groove indium wire sealing even under the high pressure up to 20 bar. In addition, the liquid-level meter is designed and fabricated to figure out the inner state of L-V separator. It consists with 19 carbon composition resistors in series. All resistors are separately calibrated in the temperature range from 77 K to 200 K. The performance of the L-V separator and the liquid-level meter is investigated with experimental tests, and the result is presented in this paper.

Numerical Performance Evaluation of an Ultra-small Lapple Cyclone Separator (초소형 Lapple 사이클론 집진기의 수치적 성능평가)

  • Park, Sumin;Kwon, Jae-Sung
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.90-95
    • /
    • 2020
  • The purpose of this study is to numerically evaluate the collection performance of an ultra-small Lapple cyclone separator for 1~10 ㎛ particles introduced at flow rate of 10 L/min. The numerical evaluation reveals that a static pressure drop occurs more dominantly inside of the cyclone separator than at the inlet and the vortex finder. Also a fluid flow in the cyclone separator is confirmed to have a helical structure heading upward in the center of cyclone separator and downward in the vicinity of wall. The investigation on dust collection efficiency of the Lapple cyclone separator shows that particles of 4~8 ㎛ diameters are collected at very lower efficiency than other sizes. Then, the cut-point diameter of the cyclone separator is 1.48 ㎛.

The development of basic structure of jellyfish separator system for a trawl net (트롤어구용 해파리 분리 배출장치 기본 구조 개발)

  • Kim, In-Ok;An, Heui-Chun;Shin, Jong-Keun;Cha, Bong-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.44 no.2
    • /
    • pp.99-111
    • /
    • 2008
  • The purpose of this study is to develop the jellyfish separator system(JSS) for reducing fishery damage by the increase of jellyfish in the sea area of Korea in summer. First of all, to find the optimum structure of a JSS, six types of JSS in trawl fishery were designed and manufactured, the underwater shape of JSS and the separating process by JSS were observed in the circulating water channel(CWC). And the field experiments were carried out in July and September 2004 in the southern sea of Korea. For the moving path of the jellyfish model in the CWC, in case that the model was larger than the mesh size of the separator net, it was guided toward the lower part of the separator net by the guiding net and discharged through the outlet. In case that the model was smaller than the mesh size of the separator net, some models which passed through the upper part of the guiding net were smaller than the mesh size of the guiding net and discharged through the outlet and most of the model which passed through the lower part of the guiding net moved to the codend passing through the separator net. According to the field experiment result, the optimum tilt angle of separator net was inferred $20^{\circ}$ that the discharge rate of jellyfish was higher than the other tilt angle of separator net and the optimum structure of JSS was inferred GS type(consists of guiding net and separator net) that the discharge rate of jellyfish was higher than S type(consists of separator net). It was demamded to carry out more study for the countermeasure to reduce loss of fish.

An Effect of Laminated Plate on the Performance of Pre-separator for Marine Oily Water Separator (선박 유수분리기 전처리 장치 성능에 미치는 적층판의 영향)

  • 이진열;한원희
    • Tribology and Lubricants
    • /
    • v.16 no.6
    • /
    • pp.440-447
    • /
    • 2000
  • It's a tendency to strengthen related international laws as the importance on marine oil pollution recently becomes the issue. According to the regulation of IMO, oil discharge from ships is allowed under 15 ppm only and oil filtering equipment is essential. However, for large ships using heavy fuel oil of over S.G 0.98 and viscosity 380 cSt and system oil, it has been in difficulty to process with existing filtering type of oily water separator. Oily water pre-separator of laminated plate type which is one of gravity type separator has very simple structure and it also makes easier to maintain and repair. In another words, it fits well to process large amount of rich oil with high specific gravity. In this paper, oily water pre-separator of laminated plate type has been studied. The function of emulsified oil and 4 different types of oil have been analyzed and each character has been investigated and proved by experiments. As the result of it, the efficiency of separating oil water has been advanced by 10% in case equipped with pre-separator. In addition, the higher temperature is and the more laminated plate has, it turns out to be getting more effect.

Assessment of the Stiffness factor of the Separator Plate at the Elevated Temperature (연료전지 분리판의 고온 강성 인자 연구)

  • Kim, J.H.;Woo, D.U.;Lee, S.W.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.296-299
    • /
    • 2007
  • The focus of this study is to estimate the stiffness factor of the separator plate of MCFC (Molten Carbonate Fuel Cell) at the elevated temperature. The process factors affecting the stiffness of the separator plate were chosen to determine the most important factor using the finite element analysis with the Taguchi method. The most influential factor, picked out by the ANOYA, turned out the pitch in the separator plate.

  • PDF

Development of a Miniature Aerosol Separator for a Black Carbon Measuring Instrument (블랙카본 측정기용 초소형 사이클론 집진기 개발)

  • An, Ik-Hyun;Lim, Jun-Hyung;Lee, Hyo-Young;Yook, Se-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.42-48
    • /
    • 2020
  • Given the increasing interest in air pollution, several technologies to measure black carbon (BC) aerosol particles have been developed. As most BC aerosol particles are smaller than 1 ㎛, it is necessary to pre-separate the particles by size before a BC measuring instrument samples the aerosol particles. In this study, a miniature cyclone separator for portable BC measuring instruments was developed. A numerical approach was used to design the miniature cyclone separator with operating flow rates of 50, 100, or 150 mLPM, and then a prototype cyclone separator was manufactured for experimental validation. The numerical results of the cut-off size and pressure drop of the miniature cyclone separator agreed well with the experimental data. The cut-off sizes of the miniature cyclone separator were determined to be 2.9, 0.94, and 0.63 ㎛ for operating flow rates of 50, 100, and 150 mLPM, respectively. Thus, the miniature cyclone separator is suitable for use as a sampling inlet for the portable black carbon measuring instrument to sample BC aerosol or PM2.5 aerosol.