• Title/Summary/Keyword: severe condition

Search Result 1,549, Processing Time 0.041 seconds

Wear Behavior of Al/SiC in Thermal Spray Process (알루미늄 판 표면에 용사된 Al/SiC의 마모 거동)

  • Kim, H.J.;You, M.H.;Lee, S.H.;Lee, K.J.
    • Journal of Power System Engineering
    • /
    • v.10 no.2
    • /
    • pp.111-116
    • /
    • 2006
  • Tribologcal property of the ceramics used in severe condition was investigated and both $Al_2O_3$ ball and Al/SiC composite made by thermal spray process[TSP] were used as a specimen in this study. Four kinds of material couple in ball and disk specimens were tested in the dry condition by using ball-on-disk type tribo-tester. Friction coefficient, surface roughness, wear rate, and photograph of the worn surface were investigated. Generally, High SiC contents[$40{\sim}50%$] specimens showed very low friction coefficient below 0.05 and little wear rate in dry condition. And also, low SiC contents[0%] specimens showed a moderate wear rate and high coefficient of friction at the same condition.

  • PDF

Auditory Recognition of Digit-in-Noise under Unaided and Aided Conditions in Moderate and Severe Sensorineural Hearing Loss

  • Aghasoleimani, Mina;Jalilvand, Hamid;Mahdavi, Mohammad Ebrahim;Ahmadi, Roghayeh
    • Journal of Audiology & Otology
    • /
    • v.25 no.2
    • /
    • pp.72-79
    • /
    • 2021
  • Background and Objectives: The speech-in-noise test is typically performed using an audiometer. The results of the digit-in-noise recognition (DIN) test may be influenced by the flat frequency response of free-field audiometry and frequency of the hearing aid fit based on fitting rationale. This study aims to investigate the DIN test in unaided and aided conditions. Subjects and Methods: Thirty four adults with moderate and severe sensorineural hearing loss (SNHL) participated in the study. The signal-to-noise ratio (SNR) for 50% of the DIN test was obtained in the following two conditions: 1) the unaided condition, performed using an audiometer in a free field; and 2) aided condition, performed using a hearing aid with an unvented individual earmold that was fitted based on NAL-NL2. Results: There was a statistically significant elevation in the mean SNR for the severe SNHL group in both test conditions when compared with that of the moderate SNHL group. In both groups, the SNR for the aided condition was significantly lower than that of the unaided condition. Conclusions: Speech recognition in hearing-impaired patients can be realized by fitting hearing aids based on evidence-based fitting rationale rather than by measuring it using free-field audiometry measurement that is utilized in a routine clinic setup.

Investigation on Severe Aerodynamic Load Condition about Pantograph (판토그래프 가혹공력하중에 대한 연구)

  • Hwang, Jae-Ho;Lee, Dong-Ho;Chung, Kyung-Ryul
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.361-366
    • /
    • 2001
  • The present study describes a practical estimation procedure about the pantograph under several severe aerodynamic load conditions. As the operating speed of the Korean Train Express(KTX) reaches 350km/h, structural safety at various conditions should be examined at the design stage. In the present study, a compact and reliable procedure is developed to get aerodynamic loads on each part of the pantograph regarding the typhoon condition, the train/tunnel interaction, the train/train interaction and the side wind condition. In the estimation procedure, 3-dimensional steady and unsteady CFD simulation around the high speed train facilitates assigning the external local flow condition around the pantograph. The procedure is verified using the results of the low speed wind tunnel test at JARI and applied to 7 flow conditions and 4 operation configurations.

  • PDF

Effects of Alloying Elements on the High Pressure Wear Characteristics of Ductile Cast Iron I-Cu, Mn (구상흑연주철의 고압하 마멸특성에 미치는 합금원소의 영향 I-Cu, Mn)

  • Bang, Woong-Ho;Kang, Choon-Sik;Park, Jae-Hyun;Kweon, Young-Gak
    • Journal of Korea Foundry Society
    • /
    • v.20 no.4
    • /
    • pp.230-239
    • /
    • 2000
  • High pressure wear characteristics of DCI(Ductile Cast Iron) were investigated through unlubricated pin-on-disc wear test. Wear test were carried out at speed of 23m/min, under pressure of 3MPa and 3.3 MPa. Cu and/or Mn were added to examine the effect of alloying elements on the high pressure wear characteristics of DCI. To investigate the relationship between wear characteristics and mechanical properties of DCI, Brinell hardness and V-notched Charpy impact energy were tested. Wear surface of each specimen was observed by SEM to determine the wear mechanism of DCI under high pressure wear condition. In the mild wear region, wear characteristics of alloyed DCI specimens were very similar to that of unalloyed DCI. But mild-severe wear transition was occurred at different wear distance and wear rate of DCI specimens were changed by alloying elements. In severe wear condition, wear rate of DCI was dramatically increased by the addition of Mn. Although the addition of Cu 0.46wt% did not decrease the wear rate of DCI in the severe wear region, but it delayed the mild-severe wear transition. Under high pressure wear condition, wear rate and mild-severe wear transition were not concerned with hardness of DCI specimens, but they were deeply associated with impact energy changed by alloying elements.

  • PDF

Vacuum-assisted Closure Therapy for Treating Patients with Severe Subcutaneous Emphysema (피하기종의 Vacuum-assisted Closure Therapy)

  • Oh, Tak-hyuk;Lee, Sang Cjeol;Lee, Deok Heon;Cho, Joon Yong
    • Journal of Trauma and Injury
    • /
    • v.28 no.4
    • /
    • pp.276-279
    • /
    • 2015
  • Subcutaneous emphysema is a benign condition following trauma (pneumothorax and oropharyngeal), cervical or thoracic procedures, and mediastinal infection. However, severe subcutaneous emphysema may be related to serious complications such as respiratory failure, airway compromise, and tension- related phenomena. Many alternative therapies have been tried to treat patients with this condition. We report our experience with vacuum-assisted closure therapy for treating patients with severe subcutaneous emphysema.

  • PDF

Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable (XLPE 특고압 전력케이블의 절연 진단)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF

SUGGESTIONS FOR IMPROVMENTS OF THE RADIATION PROTECTION FOR THE EMERGENCY WORKERS DURING THE FUKUSHIMA NUCLEAR POWER PLANT ACCIDENT

  • Khasawneh, Khalid;Cho, Kun-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.103-108
    • /
    • 2014
  • Following the emergency work in Fukushima Daiichi nuclear power plant, more attention was paid for the radiation protection of workers working under severe accident condition. The protection procedure for the emergency workers, including the on-site emergency center, the seismic isolated building and the reestablishment of the radiation protection framework were analyzed to investigate drawbacks and deficiencies which led to adverse effects on the emergency planning and on emergency workers' health and comfort. Those drawbacks were identified and studied, and then suggestions were made to enhance the emergency working condition to avoid any future problems during severe accident emergency work and management.

Severe Hypothermia Accompanying Acute Subdural Hemorrhage

  • Kim, Jung-Goan;Kim, Seok-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.3
    • /
    • pp.228-230
    • /
    • 2006
  • Hypothermia is relatively a common condition and most cases involve mild hypothermia. But severe hypothermia below $30^{\circ}C$ is medical an emergency condition. We report the case of a 41-year-old man who had been left in a manhole for more than 9 hours on a freezing cold water. He was transported to our emergency room in semicomatose state with a body temperature $26.5^{\circ}C$. The patient was warmed with active rewarming. After initial stabilization, the patient was taken for a brain computed tomography and found to have large fronto-temporo-parietal[FTP] subdural hemorrhage. The patient underwent an emergent decompressive craniectomy and hematoma evacuation. After surgery, he recovered to drowsy mentation and vital signs were stable.

A study on performance improvement of position control system in hydraulic cylinder for heavy construction machinery (건설기계용 유압실린더 위치 제어시스템의 성능개선에 관한 연구)

  • 한석재;박성환;이진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1450-1454
    • /
    • 1996
  • Even though digital control type high speed solenoid valve is a little inferior to analog control type servo valve and proportional control valve in performance, it is cheap and has secure performance against pollutant and simple control circuit. But high speed solenoid valve is hardly used for heavy machinery instead of servo valve or proportional control valve that is used in severe condition because the valve itself is small capacity and it shows wide dead zone during on-off control and chattering of hydraulic cylinder by chattering of pressure. It is desirable to use low-priced and strong pollutant resistant high speed solenoid valve for obtaining reliability of operation from severe working condition because it isn't necessary to acquire response characteristic of high frequency when we consider the characteristic of heavy machinery operation. In this study, PWM control algorithm for pilot pressure control of large capacity pilot operating valve will be used for precision position control of heavy machinery hydraulic cylinder. Not only cost reduction of main control valve but also high reliability of heavy machinery in severe condition can be obtained by using this pilot operating spool valve with high speed solenoid valve.

  • PDF

Serum serotonin concentration in lean and obese dogs with myxomatous mitral valve disease

  • Kim, Kyu-Tae;Park, Hee-Myung;Hyun, Changbaig;Seo, Kyoung-Won;Song, Kun-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.4
    • /
    • pp.205-208
    • /
    • 2016
  • The aim of the present study is to investigate the potential influence of obesity as a factor in 5-hydroxytryptamine (5-HT) concentration in myxomatous mitral valve disease (MMVD) dogs. Fifty-five client-owned dogs were enrolled in a randomized trial. Dogs were classified by echocardiography into healthy (control), mild, and moderate to severe MMVD groups. Each group was subclassified by using a 9-point body condition score (BCS); lean (BCS 5-6/9) and obese groups (BCS 7.5-9/9). Dogs with moderate to severe MMVD had lower serotonin (5-HT) concentrations than the control group (p = 0.03). Dogs with moderate to severe MMVD (p = 0.017) had lower serum 5-HT concentrations than the control group in the obese group (BCS 7.5-9/9). Significant difference was found between the lean and obese groups (p = 0.015) which are not consider severe in the MMVD group. These results suggested that 5-HT concentration was decreased with the increasing severity of MMVD, and obesity might be taken into consideration when interpreting the serotonin concentration in MMVD dogs.