• Title/Summary/Keyword: shank angle

Search Result 29, Processing Time 0.029 seconds

Effects of Knee Brace on the Anterior Cruciate Ligament Injury Risk Factors during Spike Take Off in Female Volleyball Players (여자 배구 선수들의 스파이크 도약 시 무릎보호대가 전방십자인대 부상위험 요인에 미치는 영향)

  • Yang, Chang-Soo;Lim, Bee-Oh
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • In volleyball, the most common injuries are anterior cruciate ligament (ACL) tears. For this reason, volleyball players frequently use knee brace as prophylactic and rehabilitation measures. The purpose of the study was to investigate the effects of knee brace on anterior cruciate ligament injuries risk factors during spike take off in female volleyball players. Fifteen female volleyball players were recruited and performed randomly spike take off with and without knee brace. Kinematics and ground reaction data were collected to estimate the anterior cruciate ligament injuries risk factors. The ACL risk factors are knee maximum flexion angle, thigh maximum adduction angle, thigh maximum internal rotation angle, shank maximum abduction angle, shank maximum external rotation angle, knee maximum extension moment and knee maximum abduction moment. Data were analyzed with paired samples t-test with Bonfferoni collection. Female volleyball players with knee brace had no significant results in knee maximum flexion angle, thigh maximum adduction angle, thigh maximum internal rotation angle, shank maximum abduction angle and shank maximum external rotation angle compare to without knee brace. Female volleyball players, however, with knee brace showed more reduced knee maximum extension moment and knee maximal abduction moment than without knee brace. In conclusion, Female volleyball players with knee brace reduced anterior cruciate ligament stress.

Gait-Event Detection using an Accelerometer for the Paralyzed Patients (가속도계를 이용한 마비환자의 보행이벤트 검출)

  • Kong, Se-Jin;Kim, Chul-Seung;Moon, Ki-Wook;Eom, Gwang-Moon;Tack, Gye-Rae;Kim, Kyeong-Seop;Lee, Jeong-Whan;Lee, Young-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.990-992
    • /
    • 2007
  • The purpose of this study is to develop a practical gait-event detection system which is necessary for the FES (functional electrical stimulation) control of locomotion in paralyzed patients. The system is comprised of a sensor board and an event recognition algorithm. We focused on the practicality improvement of the system through 1) using accelerometer to get the angle of shank and dispensing with the foot-switches having limitation in indoor or barefoot usage and 2) using a rule-base instead of threshold to determine the heel-off/heel-strike events corresponding the stimulation on/off timing. The sensor signals are transmitted through RF communication and gait-events was detected using the peaks in shank angle. The system could detect two critical gait-events in all five paralyzed patients. The standard deviation of the gait events time from the peaks were smaller when 1.5Hz cutoff frequency was used in the derivation of the shank angle from the acceleration signals.

Changes in lower extremity alignment in standing position using a foot plate

  • Lee, Hye-Mi;Yang, Ji-Eun;Lee, Ju-Yeon;Im, Hong-Jun;Jeong, Yu-Jin;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.132-137
    • /
    • 2016
  • Objective: Eversion of the foot is created with internal rotation of the shank, and inversion of the foot is created with external rotation of the shank. The purpose of the study was to investigate the effect of continuous changes in the angle of the subtalar joint on lower extremity alignments. Design: Cross-sectional study. Methods: Seventeen healthy young adult subjects recruited. The subjects were asked to stand up in a natural standing position on a footplate with eye open and equal weight on each foot for 10s in two different conditions: The right subtalar joint was everted continuously $0^{\circ}-20^{\circ}$ and in separate segments of $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$. The averages of three trials were used. The observation of the changes in the lower extremity was performed with the use of 3-dimensional motion analysis. For data analysis, the SPSS 18.0 software using paired t-test and repeated measures analysis of variance (ANOVA) was applied. Results: The angle was significantly increased at the horizontal rotation angle of the shank, thigh, and ankle without anterior rotation of the pelvis (p<0.05). The maximum horizontal rotation angle at the thigh on $20^{\circ}$ was $-4.52^{\circ}$ in static, and $-3.10^{\circ}$ in the dynamic conditions compared to $0^{\circ}$. Conclusions: Increased unilateral foot pronation, thigh, shank, ankle horizontal rotation variance was significantly effective. The observation of the changes in foot abduction with the use of a 3-dimensional motion analysis augmented in predicting the angle values of each segment of the lower extremity. In further studies, a comparison of the right and left subtalar joints need to be investigated.

Kinmatics Analysis of pelvis and lower extremity using orientation angles during a developpe a la seconde (Developpe a la seconde 동작 시 골반과 하지의 지향각(Orientation angles)의 운동학적 분석)

  • Jung, Chul-Jung;Jeung, He-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.259-270
    • /
    • 2004
  • The purpose of this study was to analysis of pelvis and lower extremity using orientation angles during a developpe a la seconde. Data were collected by Kwon3D program. Two females professional modem dancer were participated in this experiment. Subjects performed a developpe a la seconde in meddle heights(about 90 dog.) The results were as follows. The orientation angles of pelvis were, in most cases, caused by the movement of trunk and thigh. It was restricted the movement of pelvis within narrow limits because the movement of pelvis was very important to lower extremity alignment. The orientation angle of shank against thigh showed a change of angle about $3-6^{\circ}$ in internal external rotation. The orientation angle of foot against shank showed a change of angle about $6-7^{\circ}$ in internal external rotation.

Kinematic Analysis of The Rider Postural Alignments According to The Fitting of Stirrups Lengths during Horse Walk of High Level Rider (승마 평보 시 숙련자의 등자길이 피팅에 따른 기승자세정열의 운동학적 비교분석)

  • Ryew, Che-Cheong;Hyun, Seung-Hyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.329-338
    • /
    • 2014
  • The purpose of this study was to analyze of the rider postural alignments according to the fitting of stirrups lengths during walk of high level riders. Participants selected as subject were consisted of horse riders of high level (age: $47.66{\pm}3.51yrs$, height: $168.40{\pm}4.84cm$, body weight: $73.36{\pm}15.58kg$, low extremity length: $94.76{\pm}3.98cm$, career: $23.33{\pm}5.77yrs$) and walk with 3 types of stirrup lengths(ratio of low extremity 68.04%, 73.25%, 78.48%). The variables analyzed were consisted of the displacement of Y axis (center of mass, head, thigh, shank and foot), FR angle, LR angle, dynamic postural stability index (DPSI), coefficient of variation (CV%), and distance (X axis) of low extremity limb between right and left. The displacement of Y axis in COM, thigh, shank, foot limbs were not statistically significant, but movements of head showed greater distance of B type and C type than that of A type during 1 stride of walk. The FR and LR angle in trunk of horse rider, dynamic postural stability index and, coefficient of variation didn't show significant difference statistically according to the fitting of stirrup lengths. Also the distance (X axis) of low extremity in thigh and shank didn't show significant difference statistically in between right and left, but right and left foot showed greater distance in C type than that of B and A types during walk in horse back riding. The hip and ankle joint angle not statistically significant according to stirrups lengths, But knee joint angle showed more extended according to the increase of stirrups lengths during stance and swing phase in walk.

The Process of the Interjoint and Intersegmental Coordination of Side Kick Motion in Taekwondo (태권도 옆차기 동작의 인체관절과 분절사이의 협응 과정)

  • Yoon, Chang-Jin;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.179-189
    • /
    • 2008
  • The purpose of this study was to investigate interjoint and intersegmental coordination of lower segments in skill process. For the investigation, we examined the difference of resultant linear velocity of segments and angle vs angle graph. Novice subjects were 9 male middle school students who have never been experienced a taekwondo. We analyzed kinematic variables of Side Kick motion through videographical analysis. The conclusions were as follows. 1. Examining the graph of novice subjects' maximal resultant linear velocity of the thigh, shank, and foot segment, as it gets closer to the end of the training, the maximal resultant linear velocity in each segment increases which can be assumed to be a result of the effective momentum transfer between adjacent segments. 2 This research showed a sequential transfer from trunk, to thigh, and then to shank as it gets closer to the end of learning at intersegment angular velocity, and it also showed pattern of throwlike motion and pushlike motion. 3. In three dimension of flexion-extension, adduction-abduction and internal-external rotation of the thigh and shank segment, the angle-angle diagram of knee joint and of hip joint showed that dynamic change was indicated at the beginning of learning but stable coordination pattern was indicated like skilled subject as novice subjects became skilled.

The Variability Analysis of the Kinematic Variables of the Lower Extremities During AK(above-knee) Amputee Gait (대퇴절단 환자의 보행 시 양하지의 운동학적 변인에 대한 variability 분석)

  • Seo, Uk-hyeon;Ryu, Ji-seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.131-142
    • /
    • 2005
  • This study was investigated the stability of the AK amputee gait through analysing the variability on kinematic variables between the sound leg and the prosthetic limb. The one male, AK amputee who could walk for himself with his prosthetic limb was participated in this study. Six cameras of the MCU 240 and the QTM(Qualisys Track Manager) software were used for data collecting in this study. The relative angle of both segments was the difference between the absolute angle of the distal segment and the absolute angle of the proximal segment. The coupling angles between the prosthetic limb and the sound leg were caculated on the thigh Flexion/Extension in relative to the shank Flexion/Extension and the shank Flexion/Extension n relative to the foot Flexion/Extension. In order to evaluate the variability of segment and joint angle, C.V. was used, and to evaluate the variability for coupling angles, the Relative motion calculated by vector coding method of the continuous methods was used. As stated, the gait pattern of the prosthetic limb was almost similar gait pattern of the sound leg, but the prosthetic limb showed that the gait pattern of the sound leg and the prosthetic limb were not stable against the sound leg.

Analysis of the Coordination of the Trunk Tilting Angle and Bilateral Lower Limbs According to the Stirrups Length during Trot in Equestrian: Asymmetric Index Development of Overall Movement Index Algorithm (승마 속보 시 등자 길이에 따른 체간기울기와 양측 하지의 협응성 비교분석 : 비대칭 지수 및 전체이동지수 알고리즘 개발)

  • Hyun, Seung-Hyun;Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.131-140
    • /
    • 2015
  • Purpose : The purpose of this study was to analyze the coordination of the trunk tilting angle and bilateral lower limbs according to the stirrups length during trot in equestrian. Methods : Participants selected as subject were consisted of adult male(n=7, mean age: $45.00{\pm}3.78yrs$, mean height: $172.50{\pm}2.44cm$, mean body mass: $76.95{\pm}4.40kg$, mean, mean leg length: $97.30{\pm}2.60cm$). They were divided into 3-types of stirrups lengths(67 cm, 72 cm, 77 cm) during trot. The variables analyzed were consisted of the trunk front-rear angle, lower limb joint(Right Left hip, knee, ankle), overall movement index(OMI) of the lower limbs(thigh, shank, foot) and asymmetry index(AI%) during trot. Results : The average angle in hip and knee joint showed more extended posture according to the increase of stirrups lengths and ankle angle showed more plantarflexion posture according to increase of stirrups length during 1 stride in trot. Also, average angle showed more extended posture in right hip and ankle joint than that of left. The angle of knee joint didn't show significant difference statistically between right and left. Also asymmetric index in average angle of hip, knee and ankle joint didn't show significant difference statistically in between lower limbs, but hip joint showed higher asymmetric index in stirrup length of 77 cm and ankle joint showed higher asymmetric index in stirrup length of 67 cm than that of the others respectively. The FR angle in trunk of horse-rider showed relative backward leaning motions at stirrup length of 67 cm and 77 cm than that of stirrup length of 72 cm during stance and swing phase. OMI in thigh, shank, and foot limbs didn't show significant difference statistically according to the stirrups length of right and left lower limbs, but left lower limbs showed higher index than that of right lower limb. Stirrup length of 72 cm in shank and foot limbs showed higher index than that of stirrup length of 67 cm and 77 cm. But stirrup length of 72 cm showed higher asymmetric index than that of stirrups length of 67 cm and 77 cm. Conclusions : When considering the above, 72 cm(ratio of lower limb 74.04%) stirrup lengths could be useful in posture correction and stabilization than 67cm(ratio of lower limb 68.69%) and 77 cm(ratio of lower limb 79.18%) stirrup lengths during trot in horse back riding.

Effect of the Tolerance Parameters of the Horn on the Vibration of the Thermosonic Transverse Bonding Flip Chip System (횡 방향 플립 칩 초음파 접합 시 혼의 공차변수가 시스템의 진동에 미치는 영향)

  • Jung, Ha-Kyu;Kwon, Won-Tae;Yoon, Byung-Ok
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.1
    • /
    • pp.116-121
    • /
    • 2009
  • Thermosonic flip chip bonding is an important technology for the electronic packaging due to its simplicity, cost effectiveness and clean and dry process. Mechanical properties of the horn and the shank, such as the natural frequency and the amplitude, have a great effect on the bonding capability of the transverse flip chip bonding system. In this research, two kinds of study are performed. The first is the new design of the clamp and the second is the effect of tolerance parameters to the performance of the system. The clamp with a bent shape is newly designed to hold the nodal point of the flip chip. The second is the effect of the design parameters on the vibration amplitude and planarity at the end of the shank. The variation of the tolerance parameters changes the amplitude and the frequency of the vibration of the shank. They, in turn, have an effect on the quantity of the plastic deformation of the gold ball bump, which determined the quality of the flip chip bonding. The tolerance parameters that give the great effect on the amplitude of the shank are determined using Taguchi's method. Error of set-up angle, the length and diameter of horn and error of the length of the shank are determined to be the parameters that have peat effect on the amplitude of the system.

Deburring of Intersection Holes (교차구멍 에서의 디버링)

  • 박노진;김권희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1424-1428
    • /
    • 2004
  • A new design for deburring tools for intersecting holes is introduced. The tool tip is mounted on a slender cantilever assembled into a circular shank. The tool tip has been design to cover ranges of exit angle and diameter ratio between intersecting holes. The design is an improvement over the previous ones by the authors. Experiments have been performed on AL6061. With the new design, mild exit burrs with exit angles greater than 45$^{\circ}$ are successfully removed. For large burrs with smaller exit angles, however, the deburring could be incomplete.

  • PDF