• 제목/요약/키워드: shear design

검색결과 3,132건 처리시간 0.031초

Tests of reinforced concrete deep beams

  • Lu, Wen-Yao;Hsiao, Hsin-Tai;Chen, Chun-Liang;Huang, Shu-Min;Lin, Ming-Che
    • Computers and Concrete
    • /
    • 제15권3호
    • /
    • pp.357-372
    • /
    • 2015
  • This study reports the test results of twelve reinforced concrete deep beams. The deep beams were tested with loads applied through and supported by columns. The main variables studied were the shear span-to-depth ratios, and the horizontal and vertical stirrups. The shear strengths can be effectively enhanced for deep beams reinforced with both horizontal and vertical stirrups. The test results indicate the shear strengths of deep beams increase with the decrease of the shear span-to-depth ratios. The normalized shear strengths of the deep beams did not increase proportionally with an increase in effective depth. An analytical method for predicting the shear strengths of deep beams is proposed in this study. The shear strengths predicted by the proposed method and the strut-and-tie model of the ACI Code are compared with available test results. The comparison shows the proposed method can predict the shear strengths of reinforced concrete deep beams more accurately than the strut-and-tie model of the ACI Code.

Design of composite plate girders under shear loading

  • Shanmugam, N.E.;Baskar, K.
    • Steel and Composite Structures
    • /
    • 제6권1호
    • /
    • pp.1-14
    • /
    • 2006
  • Experiments have been carried out on six composite and two plain steel plate girders under shear loading to understand the elastic and inelastic behaviour of such girders. The failure mechanism assumed and used to develop design equations is normally based on the failure patterns observed in the experiments. Therefore, different types of cracks and failure patterns observed in the experiments are reviewed briefly first. Based on the observed failure patterns, a design method to predict the ultimate shear capacity of composite plate girders is proposed in this paper. The values of ultimate shear capacity obtained using the proposed design method are compared with the corresponding experimental values and it is found that the proposed method is able to predict the shear capacity accurately.

Seismic design of connections between steel outrigger beams and reinforced concrete walls

  • Deason, Jeremy T.;Tunc, Gokhan;Shahrooz, Bahram M.
    • Steel and Composite Structures
    • /
    • 제1권3호
    • /
    • pp.329-340
    • /
    • 2001
  • Cyclic response of "shear" connections between steel outrigger beams and reinforced concrete core walls is presented in this paper. The connections investigated in this paper consisted of a shear tab welded onto a plate that was connected to the core walls through multiple headed studs. The experimental data from six specimens point to a capacity larger than the design value. However, the mode of failure was through pullout of the embedded plate, or fracture of the weld between the studs and plate. Such brittle modes of failure need to be avoided through proper design. A capacity design method based on dissipating the input energy through yielding and fracture of the shear tab was developed. This approach requires a good understanding of the expected capacity of headed studs under combined gravity shear and cyclic axial load (tension and compression). A model was developed and verified against test results from six specimens. A specimen designed based on the proposed design methodology performed very well, and the connection did not fail until shear tab fractured after extensive yielding. The proposed design method is recommended for design of outrigger beam-wall connections.

철근콘크리트 보에 사용된 전단보강철근의 항복강도 제한에 대한 평가 (Evaluation on the Maximum Yield Strength of Steel Stirrups in Reinforced Concrete Beams)

  • 이진은;이정윤
    • 콘크리트학회논문집
    • /
    • 제24권6호
    • /
    • pp.685-693
    • /
    • 2012
  • 현재 콘크리트설계기준에서는 전단보강철근의 항복강도를 제한하고 있다. 이 연구에서는 ACI318-08, EC2-02, CSA-04에서 제시하고 있는 전단설계기준을 이용한 계산값과 예제 실험체 데이터 값의 비교 분석을 통하여 각 기준의 전단보강철근 항복강도 제한의 상향조정에 대하여 판단해 보았다. 실험값과 계산값의 비교는 전단보강철근의 항복 강도를 제한하지 않았을 경우와 항복강도를 제한하였을 경우, 항복강도 및 철근비를 제한하였을 경우 세 가지로 나누어 분석하였다. 분석 결과는 전단보강철근의 항복강도를 제한하지 않았을 경우가 가장 실험값을 잘 예측하는 것으로 나타났다. 또한 항복강도를 기준으로 비교했을 때, 기준에서 제한하고 있는 항복강도 이상의 고강도에서도 실험값에 가까운 값을 예측함을 확인하였다. 따라서 기존의 전단설계수식에 고강도 전단보강철근의 강도를 적용하더라도 수식이 성립한다고 볼 수 있으며 기준상에서 제한하고 있는 항복강도를 상향조정하여도 적용상의 불리함이 없을 것으로 판단된다.

Modeling shear capacity of RC slender beams without stirrups using genetic algorithms

  • Nehdi, M.;Greenough, T.
    • Smart Structures and Systems
    • /
    • 제3권1호
    • /
    • pp.51-68
    • /
    • 2007
  • High-strength concrete (HSC) is becoming increasingly attractive for various construction projects since it offers a multitude of benefits over normal-strength concrete (NSC). Unfortunately, current design provisions for shear capacity of RC slender beams are generally based on data developed for NSC members having a compressive strength of up to 50 MPa, with limited recommendations on the use of HSC. The failure of HSC beams is noticeably different than that of NSC beams since the transition zone between the cement paste and aggregates is much denser in HSC. Thus, unlike NSC beams in which micro-cracks propagate around aggregates, providing significant aggregate interlock, micro-cracks in HSC are trans-granular, resulting in relatively smoother fracture surfaces, thereby inhibiting aggregate interlock as a shear transfer mechanism and reducing the influence of compressive strength on the ultimate shear strength of HSC beams. In this study, a new approach based on genetic algorithms (GAs) was used to predict the shear capacity of both NSC and HSC slender beams without shear reinforcement. Shear capacity predictions of the GA model were compared to calculations of four other commonly used methods: the ACI method, CSA method, Eurocode-2, and Zsutty's equation. A parametric study was conducted to evaluate the ability of the GA model to capture the effect of basic shear design parameters on the behaviour of reinforced concrete (RC) beams under shear loading. The parameters investigated include compressivestrength, amount of longitudinal reinforcement, and beam's depth. It was found that the GA model provided more accurate evaluation of shear capacity compared to that of the other common methods and better captured the influence of the significant shear design parameters. Therefore, the GA model offers an attractive user-friendly alternative to conventional shear design methods.

개구부를 갖는 전단벽의 전단강도 (Shear Strength of R/C Shear Walls with Openings)

  • 윤현도;최창식;황선경;한병찬;박완신
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.223-228
    • /
    • 2003
  • Results of 61 framed reinforced concrete shear walls with openings were reviewed to evaluate the current design provisions for nominal shear strength. Provisions for ACI 318-02 and AIJ Code pertaining to shear design of shear walls evaluated the applicability of shear walls with openings subjected to lateral and vertical loads. Evaluation of test results indicates that the nominal unit shear strength($\Psi$=1.0) calculated using the provisions of ACI and AIJ does not represent the observed shear strength well. Based on the limited database considered in this study, A reasonable lower bound to the shear strength of high-strength concrete shear walls is found to be $1.09\sqrt{f_{cu}}$ kgf/$\textrm{cm}^2$.

  • PDF

직접전단시험과 이산요소법에 기반한 전단 시뮬레이션과의 비교 (A Comparison of the Direct Shear Test and Shear Simulation Based on the Discrete Element Method)

  • 정성헌;손정현
    • 한국기계가공학회지
    • /
    • 제19권3호
    • /
    • pp.86-91
    • /
    • 2020
  • An important factor of rough road modeling is analyzing the shear behavior properties of the rough road. These properties influence the drawbar pull of the tool when interacting with the soil used in agriculture. Furthermore, shear behavior properties are important because sinkage and shear stress are generated when wheels drive on rough roads. In this study, we performed a direct shear test to investigate the shear behavior properties of soils and compare with the direct shear simulation; shear force derived by the coupled analysis of discrete element method; and multi-body dynamics. Soil contact parameters were measured in a wheel and soil contact simulation followed by comparison of the simulated and experimentally measured shear force.

Damage assessment and performance-based seismic design of timber-steel hybrid shear wall systems

  • Li, Zheng;He, Minjuan;Li, Minghao;Lam, Frank
    • Earthquakes and Structures
    • /
    • 제7권1호
    • /
    • pp.101-117
    • /
    • 2014
  • This paper presents a reliability-based analysis on seismic performance of timber-steel hybrid shear wall systems. Such system is composed of steel moment resisting frame and infill wood frame shear wall. The performance criteria of the hybrid system with respect to different seismic hazard levels were determined through a damage assessment process, and the effectiveness of the infill wood shear walls on improving the seismic performance of the hybrid systems was evaluated. Performance curves were obtained by considering different target non-exceedance probabilities, and design charts were further established as a function of seismic weight. Wall drift responses and shear forces in wood-steel bolted connections were used as performance criteria in establishing the performance curves to illustrate the proposed design procedure. It was found that the presence of the infill wood shear walls significantly reduced the non-performance probabilities of the hybrid wall systems. This study provides performance-based seismic evaluations on the timber-steel hybrid shear walls in support of future applications of such hybrid systems in multi-story buildings.

A study on the behaviour of coupled shear walls

  • Bhunia, Dipendu;Prakash, Vipul;Pandey, Ashok D.
    • Structural Engineering and Mechanics
    • /
    • 제42권5호
    • /
    • pp.645-675
    • /
    • 2012
  • An effective design technique for symmetrical coupled shear walls is presented. Proposed formulation including assumptions and steps with mathematical formulation has been elaborated to make the design technique. An example has been considered to validate the technique with the DRAIN-3DX (1993) and SAP V 10.0.5 (2000) nonlinear programs. Parametric study has also been considered to find out the limitations along with remedial action of this technique. On the other hand, nonlinear static analysis is considered to determine the response reduction factor of coupled shear walls. Finally, it has been concluded in this paper that the proposed design technique can be considered to design the coupled shear walls under seismic motion.

Impact of shear wall design on performance and cost of RC buildings in moderate seismic regions

  • Mahmoud, Sayed;Salman, Alaa
    • Earthquakes and Structures
    • /
    • 제21권5호
    • /
    • pp.489-503
    • /
    • 2021
  • This research aims to investigate the seismic response of RC shear wall buildings of 5-, 6-, 7-, 8-, 9-, and 10-story designed as conventional and ductile and located in moderate seismic zone in Saudi Arabia in accordance with the seismic provisions of the American code ASCE-7-16. Dynamic analysis is conducted using the developed models in ETABS and the design spectra of the selected zone. The seismic responses of a number of design variations are evaluated in terms of story displacements, drift, shear and moments of both conventional and ductile building models as performance measures and presented comparatively. In addition, pushover analysis is also performed for the lowest and highest building models. Cost estimate of ductile and conventional walls is evaluated and compared to each other in terms of weight of reinforcement bars. In addition, due to the complexity of design and installation of ductile shear walls, sensitivity analysis is performed as well. It is observed that conventional design considerably increases induced seismic responses as well as cost compared to ductile one.