• 제목/요약/키워드: shear design

검색결과 3,131건 처리시간 0.027초

Retrofitting by adhesive bonding steel plates to the sides of R.C. beams. Part 2: Debonding of plates due to shear and design rules

  • Oehlers, Deric. J.;Nguyen, Ninh T.;Bradford, Mark A.
    • Structural Engineering and Mechanics
    • /
    • 제9권5호
    • /
    • pp.505-518
    • /
    • 2000
  • A major cause of premature debonding of tension face plates is shear peeling (Jones et al. 1988, Swamy et al. 1989, Ziraba et al. 1994, Zhang et al. 1995), that is debonding at the plate ends that is associated with the formation of shear diagonal cracks that are caused by the action of vertical shear forces. It is shown in this paper how side plated beams are less prone to shear peeling than tension face plated beams, as the side plate automatically increases the resistance of the reinforced concrete beam to shear peeling. Tests are used to determine the increase in the shear peeling resistance that the side plates provide, and also the effect of vertical shear forces on the pure flexural peeling strength that was determined in the companion paper. Design rules are then developed to prevent premature debonding of the plate ends due to peeling and they are applied to the strengthening and stiffening of continuous reinforced concrete beams. It is shown how these design rules for side plated beams can be adapted to allow for propped and unpropped construction and the time effects of creep and shrinkage, and how side plates can be used in conjunction with tension face plates.

장방형 철근 콘크리트 전단벽의 연성 보강 (Ductility Confinement of RC Rectangular Shear Wall)

  • 강수민;박홍근
    • 콘크리트학회논문집
    • /
    • 제14권4호
    • /
    • pp.530-539
    • /
    • 2002
  • 전단벽의 연성도 확보를 위한 단부횡보강 설계에 있어서, 현재 설계기준들은 경험적이며 강제적이다. 즉, 현재 설계기준은 연성도 요구량에 관계없이 단부횡보강영역과 상세를 정해 놓고 있으며, 따라서 성능기초설계에 부적합하다. 본 연구의 목적은 성능기초설계에 적합한 전단벽의 연성도 설계방법을 개발하는 것이다. 단부횡보강영역에 따른 전단벽의 연성도변화를 조사하기 위하여 실험연구를 수행하였으며 압축대를 모델링하기 위하여 각기 다른 횡보강영역을 갖는 시험체에 편심축하중을 가력하였다. 실험연구를 통하여 횡보강된 벽체 압축대의 강도, 연성도, 파괴모드 등을 연구하였으며, 벽체 단면 전체에서 단부 횡보강으로 인하여 발생하는 연성도 및 파괴시점을 조사하기 위하여 비선형 수치해석을 수행하였다. 실험과 해석연구 결과를 기반으로 하여 전단벽의 연성도 설계방법을 개발하였다. 제안된 설계방법을 이용하여, 주어진 연성도 요구량에 맞게 단부횡보강영역과 횡보강량을 정확히 결정할 수 있으며, 따라서 벽체의 연성거동을 보장하는 동시에 경제적인 벽체설계가 가능하게 되었다.

Behaviour and design of stainless steel shear connectors in composite beams

  • Yifan Zhou;Brian Uy;Jia Wang;Dongxu Li;Xinpei Liu
    • Steel and Composite Structures
    • /
    • 제46권2호
    • /
    • pp.175-193
    • /
    • 2023
  • Stainless steel-concrete composite beam has become an attractive structural form for offshore bridges and iconic high-rise buildings, owing to the superior corrosion resistance and excellent ductility of stainless steel material. In a composite beam, stainless steel shear connectors play an important role by establishing the interconnection between stainless steel beam and concrete slab. To enable the best use of high strength stainless steel shear connectors in composite beams, high strength concrete is recommended. To date, the application of stainless steel shear connectors in composite beams is still very limited due to the lack of research and proper design recommendations. In this paper, a total of seven pushout specimens were tested to investigate the load-slip behaviour of stainless steel shear connectors. A thorough discussion has been made on the differences between stainless steel bolted connectors and welded studs, in terms of the failure modes, load-slip behaviour and ultimate shear resistance. In parallel with the experimental programme, a finite element model was developed in ABAQUS to simulate the behaviour of stainless steel shear connectors, with which the effects of shear connector strength, concrete strength and embedded connector height to diameter ratio (h/d) were evaluated. The obtained experimental and numerical results were analysed and compared with existing codes of practice, including AS/NZS 2327, EN 1994-1-1 and ANSI/AISC 360-16. The comparison results indicated that the current codes need to be improved for the design of high strength stainless steel shear connectors. On this basis, modified design approaches were proposed to predict the shear capacity of stainless steel bolted connectors and welded studs in the composite beams.

제형 파형강판 복부판의 전단 설계 (Shear Design of Trapezoidally Corrugated Steel Webs)

  • 문지호;이종원;최병호;이학은
    • 대한토목학회논문집
    • /
    • 제28권4A호
    • /
    • pp.497-505
    • /
    • 2008
  • 파형강판은 아코디언 효과로 인하여 전단력에만 저항하는 특징이 있다. 파형강판에 작용하는 전단력으로 인하여 파형강판은 국부, 전체 및 연성 전단 좌굴에 의한 파괴가 발생할 수 있다. 여러 연구자들에 의하여 파형강판의 전단 거동에 관한 연구가 이루어졌으나, 파형강판의 전단 거동에 관한 명확한 규명이 이루어 지지 않아 보수적인 설계 방법이 적용되고 있는 실정이다. 본 연구에서는 파형강판의 전단 좌굴 강도에 대한 연구를 수행하였으며, 연구 결과를 검증하기 위하여 파형강판의 전단 좌굴 실험을 실시하였다. 먼저, 기존 연구자들이 제시하였던 국부, 전체 및 연성 좌굴 응력식을 실 교량 제원을 고려하여 간략하게 나타내었으며, 이 과정에서 전체 및 연성 전단 좌굴 계수와 파형강판의 전단 좌굴 계수를 제시하였다. 이러한 전단 좌굴 계수와 좌굴 곡선을 이용하여 파형강판의 전단 강도를 결정할 수 있다. 실험결과와 기존 연구자들의 결과를 본 연구의 전단 강도와 비교하였으며, 그 결과 제안된 강도는 제형 파형강판의 전단 강도를 합리적으로 평가하는 것으로 나타났다.

Crack-controlled design methods of RC beams for ensuring serviceability and reparability

  • Chiu, Chien-Kuo;Saputra, Jodie;Putra, Muhammad Dachreza Tri Kurnia
    • Structural Engineering and Mechanics
    • /
    • 제82권6호
    • /
    • pp.757-770
    • /
    • 2022
  • For the design of flexural and shear crack control for reinforced concrete (RC) beams related to serviceability and reparability ensuring, eight simply-supported normal-strength reinforced concrete (NSRC) beam specimens are tested and the existing high-strength reinforced concrete (HSRC) experimental data are included in the investigation of this work. According to the investigation results of flexural and shear cracks, this works modifies the existing design formulas to determine the spacing of the tensile reinforcement for the flexural crack control of a HSRC/NSRC beam design. Additionally, for a specified shear crack width of 0.4 mm, the allowable stresses of the shear reinforcement are also identified. For the serviceability and reparability ensuring of HSRC/NSRC beams, this works proposes the relationship curves between the maximum flexural width and allowable stress of the tensile reinforcement, and the relationship curves between the shear crack width and allowable shear force that can be used to do the crack width control directly.

블록전단파괴 : State of the Arts (Block Shear Failure : State of the Arts)

  • 장선재;이우철;임남형;이진옥
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.75-78
    • /
    • 2008
  • Limit states of a tension member are the yielding of gross section, fracture of net section, and block shear failure. Block shear failure is very complicated than other limit state because of interaction of tension and shear failure. Block shear failure is studied continuously since the 1970s. However, failure model to estimate the strength of block shear failure provided in current design specifications is not reflective of the failure mode observed in the various experimental studies. Comparisons between the experimental results and design rules in various specifications about the block shear failure were conducted in this study. Also, the need for further studies of block shear failure were proposed.

  • PDF

Shear bond failure in composite slabs - a detailed experimental study

  • Chen, Shiming;Shi, Xiaoyu;Qiu, Zihao
    • Steel and Composite Structures
    • /
    • 제11권3호
    • /
    • pp.233-250
    • /
    • 2011
  • An experimental study has been carried out to reveal the shear-bond failure mechanism of composite deck slabs. Thirteen full scale simply supported composite slabs are studied experimentally, with the influence parameters like span length, slab depth, shear span length and end anchorage provided by steel headed studs. A dozen of strain gauges and LVDTs are monitored to capture the strain distribution and variation of the composite slabs. Before the onset of shear-bond slip, the longitudinal shear forces along the span are deduced and found to be proportional to the vertical shear force in terms of the shear-bond strength in the m-k method. The test results are appraised using the current design procedures. Based on the partial shear-bond connection at the ultimate state, an improved method is proposed by introducing two reduction factors to assess the moment resistance of a composite deck slab. The new method has been validated and the results predicted by the revised method agree well with the test results.

직매형 앵커기초의 전단설계를 위한 ACI 349 Code의 평가 (An Evaluation of ACI 349 Code for Shear Design of CIP Anchor)

  • 장정범;황경민;서용표
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.464-470
    • /
    • 2005
  • The numerical analysis is carried out to identify the influence of design factors to shear capacity of cast-in-place (CIP) anchor in ACI 349 Code that is available for the design of fastening system at Nuclear Power Plant (NPP) in this study. The MASA program is used to develop the numerical analysis model and the developed numerical analysis model is verified on a basis of the various test data of CIP anchor. Both $l/d_o$ and $c_1/l$ we considered as design factors. As a result, the variation of $l/d_o$ has no influence on the shear capacity of CIP anchor but $c_1/l$ has a large influence on the shear capacity of CIP anchor, Therefore, it is proved that ACI 349 Code may give a non-conservative results compared with real shear capacity of CIP anchor according to $c_1/l$.

  • PDF

보강 철근 정착 홀을 갖는 합성 전단연결재를 적용한 콘크리트 충전 PHC말뚝의 전단성능 평가 (Shear Experiments on Concrete Filled PHC Pile with Composite Shear Connectors with Rebar Holes)

  • 김정회;박영식;민창식
    • 콘크리트학회논문집
    • /
    • 제29권3호
    • /
    • pp.259-266
    • /
    • 2017
  • 본 연구는 PHC말뚝의 단점인 전단력을 보강한 기능성말뚝을 개발하여 보다 경제적이고 합리적인 말뚝의 현장 적용에 기여하고자 하였다. 본 연구를 통해 개발된 CFP말뚝은 링형 합성 전단연결재를 배치하고 PHC말뚝 중공부에 콘크리트를 속채움함으로써 말뚝의 전단성능을 증대시키고, PHC말뚝 내 보강철근(H13-8ea)과 말뚝 중공부의 보강철근(H19-8ea)을 배치하여 횡보강철근비 증대에 따른 전단강도를 향상시켰다. 또한, 속채움 콘크리트와 PHC말뚝의 합성거동을 위해 말뚝 보강철근의 정착 홀이 형성된 합성 전단연결재를 배치하여 보강철근의 다월력을 말뚝의 전단강도 증진에 효과적으로 반영시켰다. CFP말뚝의 전단설계와 성능을 검증하고자 도로교설계기준의 한계상태설계법(2012)을 적용한 전단강도를 산출하였고, 말뚝 시험규정인 KS F 4306에서 제시한 실험방법을 통해 결과값을 비교 검토하였다. CFP말뚝의 단면별 설계전단강도와 실험결과 각 시험체는 설계전단강도 대비 평균 2.20, 2.15, 2.05의 안전율을 확보하는 것으로 나타나 효과적인 전단강도 예측이 가능할 것으로 생각된다.

휨강성을 고려한 수정 FHWA 쏘일네일 설계법 제안 (Modified FHWA Design Method Considering Bending Stiffness of Soil Nail)

  • 김낙경;정정희;주용선;김성규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1406-1416
    • /
    • 2008
  • Soil nailing is used as a method of slope stabilization and excavation support. The design method of soil nail are based on experience or assumption of interaction between soil and reinforcement. Most design methods simply considers the tension of reinforcement for analysis of slope stabilization. Soil nails interact with soils under combined loading of shear and tension. Jewell & Pedley(1990) suggested a design equation of shear force with bending stiffness and discussed that the magnitude of the maximum shear force is small in comparison with the maximum axal force. However, they have used a very conservative limiting bearing stress on nails. This paper discusses that the shear strength of soil nails should not be disregarded with proper bearing stresses on nails. The modified FHWA design method was proposed by considering shear forces on nails with bending stiffness.

  • PDF