Punching Shear Strength of CFT Column to RC Flat Plate Connections Reinforced with Shearhead (전단머리 보강 CFT기둥-RC 무량판 접합부의 펀칭전단강도)

  • Kim, Jin-Won;Lee, Cheol-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.423-433
    • /
    • 2012
  • This paper summarizes full-scale gravity-load test results on CFT column-to-RC flat plate connections reinforced with shearhead. CFT construction has many structural and constructional advantages over conventional steel and RC column construction and is gaining wide acceptance. Meanwhile the use of RC flat plate system in the basement and residential floors of tall buildings is often mandatory to reduce story height and enable rapid construction in domestic practice. Combining CFT column and flat plate floor is expected to result in further rapid construction. However, the issues related to connecting CFT column to RC flat plate have not been fully addressed yet. Several promising connecting schemes by using steel shearhead were proposed and tested in this study. Test results showed that the proposed connection can exhibit the punching shear strength higher than RC flat plate counterparts. An empirical formula that can reasonably predicts the punching shear strength of the proposed connection was also proposed.

Analysis of CFT Column-RC Flat Plate Interior Connections under Lateral Load (횡하중을 받는 CFT기둥-RC무량판 접합부의 해석연구)

  • Song, Jin-Kyu;Song, Ho-Bum;Oh, Sang-Won;Kim, Byung-Jo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.867-870
    • /
    • 2008
  • Flat plate system has many advantages, story height reduction, a term of works shortening and changeableness of space, etc. However structures become a tendency of higher stories and when we use RC column, the size of column grow larger. For this reason the use of CFT column is increasing more and more. Accordingly, this study carried out the nonlinear finite element analysis. As a result of analysis moment strength of the connection increased but ductility decreased as the top reinforcement ratio in th effective width increased. And moment strength and ductility of the connection decreased as gravity load ratio decreased. In the case that shearhead length is not more than 0.27m, the effectiveness of shearhead length on the moment strength and ductility of the connection were small relatively to other variables. Initial stiffness and moment strength of connection increased as slab thickness increased

  • PDF