• 제목/요약/키워드: simulated concrete environment

검색결과 41건 처리시간 0.024초

모의 콘크리트 환경에서 강철 철근의 부식을 모니터링하기 위한 현장 고체 기준 전극 평가 (Assessment of In-Situ Solid-State Reference Electrode for Monitoring Corrosion of Steel Rebar in Simulated Concrete Environments)

  • 카르틱 수비아;박태준;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.281-282
    • /
    • 2023
  • The solid-state reference electrodes made of polyaniline-coated MnO2 (SSRE-PAM) and their electrochemical characteristics were studied in simulated concrete pore solutions (SCPS) containing 0 and 3.5% NaCl. Saturated calomel electrodes (SCE) have been used to conduct electrochemical studies on the stability behavior of SSRE-PAM. Open circuit potential (OCP) and potentiodynamic polarization techniques were used to assess the corrosion performance of steel rebar exposed in SCPS with 0 and 3.5% NaCl using SSRE-PAM. The results demonstrate that the SSRE-PAM was capable of identifying steel rebar in a concrete environment that was either passive or active. Potentiodynamic polarization parameters such as Ecorr and Icorr for steel rebar in SCPS containing 0 and 3.5%)NaCl are greater than that of the passive condition (0% NaCl). All the studies validate the importance of using SSRE-PAM for corrosion monitoring applications in concrete structures.

  • PDF

Simulating the influence of pore shape on the Brazilian tensile strength of concrete specimens using PFC2D

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Marji, Mohammad Fatehi
    • Computers and Concrete
    • /
    • 제22권5호
    • /
    • pp.469-479
    • /
    • 2018
  • The Brazilian tensile strength of concrete samples is a key parameter in fracture mechanics since it may significantly change the quality of concrete materials and their mechanical behaviors. It is well known that porosity is one of the most often used physical indices to predict concrete mechanical properties. In the present work the influence of porosity shape on concrete tensile strength characteristics is studied, using a bonded particle model. Firstly numerical model was calibrated by Brazilian experimental results and uniaxial test out puts. Secondly, Brazilian models consisting various pore shapes were simulated and numerically tested at a constant speed of 0.016 mm/s. The results show that pore shape has important effects on the failure pattern. It is shown that the pore shape may play an important role in the cracks initiation and propagation during the loading process which in turn influence on the tensile strength of the concrete samples. It has also been shown that the pore size mainly affects the ratio of uniaxial compressive strength to that of the tensile one in the simulated material samples.

인공 해수 간헐 조건에서의 방청제 및 혼화재를 사용한 콘크리트 압축강도 및 저항의 특성 (The characteristics of compressive strength resistance of concrete combined with corrosion inhibitors and mineral admixtures under simulated tidal condition)

  • 이용은;장태순;양우석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.641-646
    • /
    • 1998
  • The structures exposed to marine environment do not show long-term durability due to corrosion of steel and deterioration of concrete by the attack of various salts dissolved in sea water. In this study, Partial substitution of cement with fly ash(20%) or blast furnace slag(40%) was made together with the addition of 4 different corrosion-inhibitors, as a protective measure of concrete structures against chemical attack of salts. Combined effects of mineral and corrosion-inhibiting admixtures were tested by measuring the resistance and compressive strength of concretes under the simulated tidal condition, which consists of alternating 12 hour periods of immersion in artificial sea water and drying in air. Both the strength and concrete resistance were found to decrease in following order, regardless of the corrosion inhibitors the concretes with blast furnace slag, those with fly ash and those without any mineral admixtures. The interrelation between compressive strength of concrete and resistance was investigated.

  • PDF

Deterioration of tensile behavior of concrete exposed to artificial acid rain environment

  • Fan, Y.F.;Hu, Z.Q.;Luan, H.Y.
    • Interaction and multiscale mechanics
    • /
    • 제5권1호
    • /
    • pp.41-56
    • /
    • 2012
  • This study is focused on evaluation of the tensile properties of concrete exposed to acid rain environment. Acid rain environment was simulated by the mixture of sulfate and nitric acid in the laboratory. The dumbell-shaped concrete specimens were submerged in pure water and acid solution for accelerated conditioning. Weighing, tensile test, CT, SEM/EDS test and microanalysis were performed on the specimens. Tensile characteristics of the damaged concrete are obtained quantitatively. Evolution characteristics of the voids, micro cracks, chemical compounds, elemental distribution and contents in the concrete are examined. The deterioration mechanisms of concrete exposed to acid rain are well elucidated.

Simulation study on CFRP strengthened reinforced concrete beam under four-point bending

  • Zhang, Dongliang;Wang, Qingyuan;Dong, Jiangfeng
    • Computers and Concrete
    • /
    • 제17권3호
    • /
    • pp.407-421
    • /
    • 2016
  • This paper presents numerical modeling of the structural behavior of CFRP (carbon fiber reinforced polymer) strengthened RC (reinforced concrete) beams under four-point bending. Simulation of debonding at the CFRP-concrete interface was focused, as it is the main failure mode of CFRP strengthened RC beams. Here, cohesive layer was employed to model the onset of debonding, which further helps to describe the post debonding behavior of the CFRP strengthened RC beam. In addition, the XFEM approach was applied to investigate the effects of crack localization on strain field on CFRP sheet and rebar. The strains obtained from the XFEM correlate better to the test results than that from CDP (concrete damaged plasticity) model. However, there is a large discrepancy between the experimental and simulated loaddisplacement relationships, which is due to the simplification of concrete constitutive law.

피로하중을 받는 해양 콘크리트의 내구성 연구 (DURABILITY TESTING OF MARINE REINFORCED CONCRETE UNDER FATIGUE LOADING, PART I AND II)

  • 안우석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.348-353
    • /
    • 1996
  • This study addresses the evaluation of the durability of reinforced concrete marine structures subjected to fatigue loading. The laboratory investigation was carried out on full and half size reinforced concrete specimens with three different water cement ratios (0.3, 0.4, and 0.56), static and fatigue loading conditions, and epoxy-coated and regular black steel reinforcements. The marine tidal zone was simulated by alternate filling and draining of the tank (wet and dry cycled), and a galvanostatic corrosion technique to accelerate corrosion of reinforcement was used. Half-cell potentials and changes of crack width were measured periodically during the exposure and followed by ultimate strength testing. The significant findings include adverse effect of fatigue loading, existence of an explicit size effect, poor performance of epoxy coated steel, and negative effect of increasing water/cement ratio.

  • PDF

Prediction of ultimate moment anchorage capacity of concrete filled steel box footing

  • Bashir, Muhammad Aun;Furuuchi, Hitoshi;Ueda, Tamon;Bashir, M. Nauman
    • Steel and Composite Structures
    • /
    • 제15권6호
    • /
    • pp.645-658
    • /
    • 2013
  • The objective of the study is to predict the moment anchorage capacity of the concrete filled steel box (CFSB) as footing by using the 3D finite element program CAMUI developed by authors' laboratory. The steel box is filled with concrete and concrete filled steel tube (CFT) column is inserted in the box. Numerical simulation of the experimental specimens was carried out after introducing the new constitutive model for post peak behavior of concrete in compression under confinement. The experimental program was conducted to verify the reliability of the simulation results by the FE program. The simulated peak loads agree reasonably with the experimental ones and was controlled by concrete crushing near the column. After confirming the reliability of the FEM simulation, effects of different parameters on the moment anchorage capacity of concrete filled steel box footing were clarified by conducting numerically parametric study.

Effects of Cementitious Coating on Steel in Simulated Concrete Pore Solution

  • 오효림;김상효;안기용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.475-476
    • /
    • 2010
  • Hydration products formed on the steel surface may impose the resistance to corrosion of steel when a concrete is exposed to a salt environment. In the present study, ordinary Portland cement (OPC), calcium aluminate cement (CAC) and calcium hydroxide are applied as coating materials on the steel surface to consider the hydrations of each binder at corrosion. Corrosion is measured in terms of the corrosion potential and galvanic current to detect the effects in mitigating the corrosion behavior.

  • PDF

A dynamic analysis algorithm for RC frames using parallel GPU strategies

  • Li, Hongyu;Li, Zuohua;Teng, Jun
    • Computers and Concrete
    • /
    • 제18권5호
    • /
    • pp.1019-1039
    • /
    • 2016
  • In this paper, a parallel algorithm of nonlinear dynamic analysis of three-dimensional (3D) reinforced concrete (RC) frame structures based on the platform of graphics processing unit (GPU) is proposed. Time integration is performed using Newmark method for nonlinear implicit dynamic analysis and parallelization strategies are presented. Correspondingly, a parallel Preconditioned Conjugate Gradients (PCG) solver on GPU is introduced for repeating solution of the equilibrium equations for each time step. The RC frames were simulated using fiber beam model to capture nonlinear behaviors of concrete and reinforcing bars. The parallel finite element program is developed utilizing Compute Unified Device Architecture (CUDA). The accuracy of the GPU-based parallel program including single precision and double precision was verified in comparison with ABAQUS. The numerical results demonstrated that the proposed algorithm can take full advantage of the parallel architecture of the GPU, and achieve the goal of speeding up the computation compared with CPU.

콘크리트 환경과 고온의 복합환경이 FRP 보강근의 계면전단성능에 미치는 영향 (The Combined Effect of Concrete Environment and High Temperature on Interlaminar Shear Strength of FRP Reinforcement)

  • 문도영;오홍섭
    • 콘크리트학회논문집
    • /
    • 제23권6호
    • /
    • pp.749-756
    • /
    • 2011
  • FRP 보강근의 화재 노출시 내구성능에 대한 연구들은 고온 노출이 인장성능에 미치는 영향에 대한 분석이 대부분을 차지한다. 그러나, 신설 구조물에 삽입된 FRP 보강근은 먼저 콘크리트 내에서 습윤환경 및 알칼리에 의한 성능저하가 발생하며, 이와 같은 FRP 보강 콘크리트 구조물에 화재가 발생하면, 보강근은 고온에 노출된다. 그러므로 화재에 의해 손상 받은 FRP 보강근의 평가시에는 콘크리트 환경과 고온에 의한 영향을 동시에 고려하여야 한다. 이 연구에서는 장기간동안 용액에 노출된 FRP 보강근에 $60^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$$300^{\circ}C$의 온도를 가하고, 계면전단강도를 측정, 비교 하였다. 실험 결과에 따르면, 환경과 고온의 복합영향이 FRP 보강근의 역학적 특성에 미치는 영향이 환경만의 영향 또는 고온만의 영향 보다 큰 것으로 나타났다.