• Title/Summary/Keyword: single pulse

Search Result 827, Processing Time 0.038 seconds

Experimental Study on a GM-type Two-Stage Pulse Tube Refrigerator for Cryopump Applications

  • Lee, S.J.;Hong, Y.J.;Park, S.J.;Kim, H.B.;Kwon, S.B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.2
    • /
    • pp.35-38
    • /
    • 2007
  • A single-stage and two-stage pulse tube refrigerators have been designed for cryopump application. The different diameters of pulse tube and regenerator have been investigated at single-stage pulse tube refrigerator(PTR). Experiments have been performed on single-stage PTR to reach minimum temperature with optimum valve opening at a few frequencies. And the two-stage pulse tube refrigerators have been assembled with tested single-stage pulse tube and tested. When orifice turn is opened to 9 and double inlet is opened to 3 at a single-stage, the lowest temperature of 33.7 K is achieved. The cooling capacity at single-stage is 38 W at temperature of 80 K. A two-stage pulse tube refrigerator has 16.3K at the second stage and 59.7K at the first stage. The cooling capacity achieved is 16.5 W at 80 K, the first stage and 0.6 W at 20 K, the second stage. Some details on the design of pulse tube refrigerator and the experimental apparatus are given.

The Characteristic Analysis of SRM Dirven by Single-pulse Mode Considering the Voltage Ripple of DC Linke (SRM의 DC linke 전압리플을 고려한 단일 펄스 구동 방식의 특성 해석)

  • Lee, Sung-Gu;Jung, Dae-Sung;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1976-1980
    • /
    • 2008
  • This paper deals the characteristic analysis of Switched Reluctance Motor(SRM) driven by single-pulse mode considering dc link voltage ripple. Two dimensional time-stepped Finite Element Method(FEM) is used to analyze the characteristic of SRM driven by single-pulse mode with dc link voltage ripple. The analysis results is verified by experimental test.

Nanomachining on Single Crystal Silicon Wafer by Ultra Short Pulse Electrochemical Oxidation based on Non-contact Scanning Probe Lithography (비접촉 SPL기법을 이용한 단결정 실리콘 웨이퍼 표면의 극초단파 펄스 전기화학 초정밀 나노가공)

  • Lee, Jeong-Min;Kim, Sun-Ho;Kim, Tack-Hyun;Park, Jeong-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.4
    • /
    • pp.395-400
    • /
    • 2011
  • Scanning Probe Lithography is a method to localized oxidation on single crystal silicon wafer surface. This study demonstrates nanometer scale non contact lithography process on (100) silicon (p-type) wafer surface using AFM(Atomic force microscope) apparatuses and pulse controlling methods. AFM-based experimental apparatuses are connected the DC pulse generator that supplies ultra short pulses between conductive tip and single crystal silicon wafer surface maintaining constant humidity during processes. Then ultra short pulse durations are controlled according to various experimental conditions. Non contact lithography of using ultra short pulse induces electrochemical reaction between micro-scale tip and silicon wafer surface. Various growths of oxides can be created by ultra short pulse non contact lithography modification according to various pulse durations and applied constant humidity environment.

A New Single Sustain Waveform with Auxiliary Address Pulse in ac PDP

  • Park, Woong-Hee;Lim, Hyun-Muk;Lee, Jun-Young;Kang, Jung-Won
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.392-395
    • /
    • 2008
  • To improve the luminance in ac PDP, a new single sustain waveform with auxiliary address pulse is proposed. The new single sustain waveform was examined with 2 dimensional fluid codes and related experiments were performed with 42-inch XGA PDP module. At the same sustain level (= 180 V), the new waveform showed 3.6 times higher IR emission than the general waveform without auxiliary address pulse.

  • PDF

Using Pulse-Front Tilt to Measure Laser Pulses Less Than 100 Picoseconds in Duration

  • Jeong, Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.6
    • /
    • pp.318-321
    • /
    • 2015
  • We demonstrate a frequency-resolved optical grating (FROG) device for measuring the intensity and phase versus time of several-tens-of-picoseconds laser pulses, using a thick nonlinear optical crystal. The huge pulse-front tilt generated by a holographic grating increases the temporal range of the device, which can make a single-shot measurement of laser pulses less than 100 ps in duration. To verify the measurement technique, we generate double pulses using a Michelson interferometer. The measured duration of a single pulse is about 300 fs and the measured maximum delay of two pulses is 60 ps, which implies that the proposed FROG device can measure laser pulses with maximum pulse width of about 120 ps.

Domain Wall Motions in Ferromagnetic Thin Film Induced by Laser Heating Pulse

  • Park, Hyun Soon
    • Applied Microscopy
    • /
    • v.48 no.4
    • /
    • pp.128-129
    • /
    • 2018
  • Soft ferromagnetic materials are utilized for various electromagnetic devices such as magnetic recording heads and magnetic shielding. In situ observation of magnetic microstructures and domain wall motions are prerequisite for understanding and improving their magnetic properties. In this work, by the Fresnel (out-of-focus) method of Lorentz microscopy, we observe the domain wall motions of polycrystalline Ni/Ti thin film layers triggered by single-shot laser pulse. Random motions of domain walls were visualized at every single pulse.

Performance of Receive Diversity UWB Systems with Pulse Amplitude and Position Modulation

  • Kim, Sang-Choon
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.5
    • /
    • pp.498-501
    • /
    • 2010
  • In this paper, we extend ultra-wideband (UWB) single input single output (SISO) systems with a hybrid pulse amplitude and position modulation (PAPM) to single input multiple output (SIMO) systems using receive antenna diversity. The performance of a rake receive diversity combining scheme for UWB SIMO systems with a PAPM is examined in a log-normal multipath fading channel and also compared with that of a time-switched transmit diversity (TSTD) multiple input single output (MISO) system. It is seen that as the number of receive antennas increases, the receive diversity combining system improves the error performance. It is shown that the TSTD UWB MISO systems offer the performance equivalent to the receive diversity combining scheme for SIMO systems.

Analysis of ultra-short optical pulse generation by LD gain-switching (LD gain-switching에 의한 초단 광 펄스 발생 해석)

  • 김윤중;김동각;김창민
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.10
    • /
    • pp.85-92
    • /
    • 1997
  • For a InGaAsP buried - heterostructrue $1.3\mu\textrm{m}$ LD with fabry-perot cavity structure, the procedures of ultra-short optical pulse genration ar eanalyzed by simulating the rate equations. Investigting the effects of injected current pulse parameters such as bias $J_b$, pulse width $T_d$ and pulse amplitude $J_p$ on the generated optical pulses, we derive the optimum conditions to obtain a single optical pulse with strong peak value. We also observe that the repetition rate of current pulses needs to be restricted under a certain threshold to generate a train of single optical pulses, and that the period doubling phenomenon takes place by increasing the repitition rate.

  • PDF

Ultrashort Pulsed Laser Machining for Biomolecule Trapping

  • Choi, Hae-Woon;Farson, Dave F.;Lee, L.James;Lee, Ho
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.335-340
    • /
    • 2009
  • Ultrashort pulse laser drilling of polycarbonate track-etched membrane (pTEM) material was used to fabricate a mouse embryo cell trapping device. Holes with a diameter of $2{\mu}m$ to $5{\mu}m$ were fabricated on a $10{\mu}m$ thick membrane using a femtosecond laser with a 150 fs pulse width and 775 nm wavelength and multiple-pulse irradiation. In cell trapping tests, the overall cell occupancy of the machined holes in the fabricated pTEM was found to be more than 80%. The results of a single pulse and multiple pulse irradiation were compared in terms of the surface quality. It was generally found that a single pulse with high energy was less desirable than irradiation with multiple pulses of lower energy.

Parametric Study of a Sawtooth Disk Type Ozonizer Applying a Pulse Voltage. (펄스전압을 안가한 엔톱날형 오존 발생기의 특성연구)

  • 문재덕;김창수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.11
    • /
    • pp.806-812
    • /
    • 1987
  • The ozone generation characteristics are reported for a sawtooth disk to cylinger geometry using positive and negative pulse corona. A series of parametric studies was carried out to obtain optimum values for the pulse repetition frequency as well as the shape and dimensions of the discharge disk and the discharge spacing. Two types of ozonizers were studied: the single disk and the multi-disk. The results of the single disk ozonizer showed that positive corona produced a singificantly higher ozone yield than negative(7ppm/peak watt or 3.5 times larger). However the negative corona produced a much more controllable output which enabled the ozone generation to be directly controlled by adjusting the value of the peak pulse voltage. This results showed that the single disk ozonizer is ideally suited for applications requiring very small controlled quantities of ozone whereas the multi-disk unit can be designed to provide varying outputs depending upon the number of disk electrodes used.

  • PDF