• 제목/요약/키워드: single-stage and two-stage

검색결과 769건 처리시간 0.023초

Experimental Study on a GM-type Two-Stage Pulse Tube Refrigerator for Cryopump Applications

  • Lee, S.J.;Hong, Y.J.;Park, S.J.;Kim, H.B.;Kwon, S.B.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권2호
    • /
    • pp.35-38
    • /
    • 2007
  • A single-stage and two-stage pulse tube refrigerators have been designed for cryopump application. The different diameters of pulse tube and regenerator have been investigated at single-stage pulse tube refrigerator(PTR). Experiments have been performed on single-stage PTR to reach minimum temperature with optimum valve opening at a few frequencies. And the two-stage pulse tube refrigerators have been assembled with tested single-stage pulse tube and tested. When orifice turn is opened to 9 and double inlet is opened to 3 at a single-stage, the lowest temperature of 33.7 K is achieved. The cooling capacity at single-stage is 38 W at temperature of 80 K. A two-stage pulse tube refrigerator has 16.3K at the second stage and 59.7K at the first stage. The cooling capacity achieved is 16.5 W at 80 K, the first stage and 0.6 W at 20 K, the second stage. Some details on the design of pulse tube refrigerator and the experimental apparatus are given.

Modified Ac-Dc Single-Stage Converters

  • Moschopoulos, Gerry;Liu, Yan;Bassan, Sondeep
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.44-54
    • /
    • 2007
  • Ac-dc power conversion can either be done with two separate converter stages or with a single converter stage. Two-stage ac-dc converters, however, can be costly and complex, while the performance of single-stage converters is compromised due to a reduced number of components. Several researchers have therefore proposed adding some sort of auxiliary circuit consisting of a second switch and some passive elements to single-stage converters to improve their performance. Although these modified single-stage converters may have two converters, they are not two-stage converters as they do not have two separate and independently controlled converters that are always operating to convert power from one form to another. In this paper, the operation of ac-dc single-stage converters is first reviewed and their strengths and weaknesses are noted. The operation of several modified single-stage converters, including one proposed by the authors, is then discussed, and the paper concludes by presenting experimental results that confirm the feasibility of the proposed converter.

Phase II two-stage single-arm clinical trials for testing toxicity levels

  • Kim, Seongho;Wong, Weng Kee
    • Communications for Statistical Applications and Methods
    • /
    • 제26권2호
    • /
    • pp.163-173
    • /
    • 2019
  • Simon's two-stage designs are frequently used in phase II single-arm trials for efficacy studies. A concern of safety studies is too many patients who experience an adverse event. We show that Simon's two-stage designs for efficacy studies can be similarly used to design a two-stage safety study by modifying some of the design parameters. Given the type I and II error rates and the proportion of adverse events experienced in the first stage cohort, we prescribe a procedure whether to terminate the trial or proceed with a stage 2 trial by recruiting additional patients. We study the relationship between a two-stage design with a safety endpoint and an efficacy endpoint as well as use simulation studies to ascertain their properties. We provide a real-life application and a free R package gen2stage to facilitate direct use of two-stage designs in a safety study.

능동 클램프 ZVS 플라이백 컨버터의 역률개선에 관한 연구 (A Study on PFC of Active Clamp ZVS Flyback Converter)

  • 최태영;류동균;이우석;안정준;원충연;김수석
    • 조명전기설비학회논문지
    • /
    • 제15권6호
    • /
    • pp.49-57
    • /
    • 2001
  • 본 논문에서는 single-stage, two-stage 두가지 역률보상(PFC)기법을 기존의 능동 클램프 플라이백 컨버터에 적용하여 역률개선을 하였다. 삽입된 플라이백 컨버터의 능동클램프회로가 주스위치와 보조스위치의 영전압스위칭(ZVS)을 구현하며, 스위칭 손실을 줄임으로써 고효율을 얻을 수 있고, 높은 주파수에서의 스위칭이 가능하다. 하지만 일반적으로 사용되는 다이오드정류기, 평활용커패시터에 의한 낮은 역률의 문제점이 남아있다. 본 논문에서는 300[W급] 능동 클램프 ZVS 플라이백 컨버터를 설계하여 single-stage two-stage방식을 적용, 입력역률개선을 시뮬레이션과 실험에 의해 입증하고자 한다.

  • PDF

단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석 (Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System)

  • ;박성룡
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

단일 PWM 제어기에 의한 역률보상 이단 풀 브리지 컨버터에 관한 연구 (A Study on Two Stage PFC Full-Bridge Converter with a Single PWM Controller)

  • 전준상;김용;권순도;김필수;윤석호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.368-371
    • /
    • 2000
  • Two-stage power factor correction (PFC) converter with a single PWM controller is proposed. It consists of a power factor pre-regulator cascaded by an isolated DC/DC converter as in a conventional two-stage approach. However, a single PWM controller is used as in a single-stage, single-switch PFC approach. This converter gives the goof power factor correction, low line current harmonic distortions, and tight output voltage regulations. This converter also has a high efficiency by employing an soft switching method. The proposed approach has advantages such as high performance over the single-stage approach and low cost over two-stage approach. The experimental results obtained on a 300W (30V/10A) prototype PFC converter are given to verify the effectiveness of the proposed control method.

  • PDF

1단 2실린더 $CO_2$ 압축기의 실린더 형상 최적 설계 (Optimal Design of Cylinder Configuration for a 1-Stage Two Cylinder $CO_2$ Compressor)

  • 안종민;김현진;조성욱
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.119-124
    • /
    • 2008
  • Recently, focus has been drawn on natural refrigerants due to increasing concern on global warming. As a consequence, CO2 systems such as a heat pump water heater using CO2 as a refrigerant are rapidly growing on the market. Currently, rolling piston rotary compressors are widely used for CO2 heating and/or refrigeration systems. There are several ways of realizing gas compression structure. They are single stage compression with single cylinder, single stage compression with two cylinders, and two stage compression with two cylinders. In this paper, computer simulation program which was validated for a single stage rotary compressor with one cylinder has been extended for a single stage, two cylinder rotary type. Numerical investigation has been made on optimal design for the cylinder configuration using the extended simulation program. For a single stage two cylinder rotary compressor having a displacement volume of 4 cc for each cylinder, compressor efficiency has been found to be maximum when the cylinder radius and height are 31mm and 10mm, respectively.

  • PDF

단상전원에 적합한 단일단 및 2단 역률개선회로 (Two-stage & Single-stage Power Factor Correction circuits for Single-phase Power source)

  • 김철진;유병규;김충식;김영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1214-1216
    • /
    • 2004
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic contents. Typically, these SMPS have a power factor lower than 0,65. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. PFC circuit have tendency to be applied in new power supply designs. The input active power factor correction circuits can be implemented using either the two-stage or the single-stage approach. In this paper, the comparative analysis of power factor correction circuit using feedforward control with average current mode single-stage flyback method converter and two-stage converter which is combination of boost and flyback converter. The two prototypes of 50W were designed and tested a laboratory experimental. Also, the comparative analysis is confirmed by simulation and experimental results.

  • PDF

고성능 2단 축류송풍기의 공력설계를 위한 수치해석 및 실험에 관한 연구 (A Numerical Method & Experiments for the Aerodynamic Design of High Performance 2-Stage Axial Flow Fans)

  • 조진수;한철희;조이상
    • 대한기계학회논문집B
    • /
    • 제23권8호
    • /
    • pp.1048-1062
    • /
    • 1999
  • A numerical method and experiments for the aerodynamic design of high performance two-stage axial flow fans was carried out. A vortex ring element method used for the aerodynamic analysis of the propellers was extended to the fan-duct system. Fan Performance and velocity profiles at the fan inlet and outlet are compared with experimental data for the validations of numerical method. Performance test was done based on KS B 6311(testing methods for turbo-fans and blowers). The velocity profile was obtained using a 5-hole pitot tube by the non-nulling method. The two stage axial flow fan configurations for the optimal operation conditions were set by using the experimental results for the single rotating axial flow fan and the single stage axial flow fan. The single rotating axial flow fan showed relatively low efficiency due to the swirl velocities behind rotor exit which produced pressure losses. In contrast, the single stage and the two-stage axial flow fans showed performance improvements due to the swirl velocity reduction by the stator. The peak efficiency of the two stage axial flow fan was improved by 21% and 6%, compared to the single rotating axial flow fan and the single stage axial flow fan, respectively.

고 출력 고 이득 2단 도허티 전력증폭기의 설계 (Design of a High Power and High Gain Two-Stage Doherty Power Amplifier)

  • 김재곤;김지연;이동헌;김종헌
    • 한국전자파학회논문지
    • /
    • 제17권11호
    • /
    • pp.1030-1039
    • /
    • 2006
  • 본 논문에서는 최종단에 내장된 구동 증폭기를 사용하여 높은 이득을 갖는 고 출력 고 이득 도허티 전력 증폭기를 설계하였다. 2단 도허티 증폭기의 동작 특성을 2단 피킹 증폭기의 게이트 바이어스에 관한 함수로서 해석하였다. 구동단과 최종단은 각각 single-ended MRF21045 2개와 single push-pull packaged MRF21180 1개를 사용하여 제작하였다. 본 논문에서 구현된 2단 도허티 증폭기는 평균 출력 전력 15 W에서 27 dB의 이득과 23 %의 전력 부가 효율을 가진다.