• Title/Summary/Keyword: single-stage method

Search Result 571, Processing Time 0.031 seconds

High efficiency and power factor 48V/100A DC power supply of three-phase single stage method (3상 Single Stage 방식의 48V/100A급 고효율 고역률 직류 전원장치)

  • Park, J.Y.;Kim, K.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.430-432
    • /
    • 2005
  • This paper presents a novel, single stage, isolated, three-phase switching rectifier capable of switching at high frequency. The circuit topology Provides zero-voltage switching for all switches, output voltage regulation, unity input power factor, all in a single power conversion stage. Operating principle and experimental results in the 48V/100A DC power supply of three-phase single stage method are presented.

  • PDF

A Numerical Method & Experiments for the Aerodynamic Design of High Performance 2-Stage Axial Flow Fans (고성능 2단 축류송풍기의 공력설계를 위한 수치해석 및 실험에 관한 연구)

  • Cho, Jinsoo;Han, Cheolhui;Cho, Leesang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.8
    • /
    • pp.1048-1062
    • /
    • 1999
  • A numerical method and experiments for the aerodynamic design of high performance two-stage axial flow fans was carried out. A vortex ring element method used for the aerodynamic analysis of the propellers was extended to the fan-duct system. Fan Performance and velocity profiles at the fan inlet and outlet are compared with experimental data for the validations of numerical method. Performance test was done based on KS B 6311(testing methods for turbo-fans and blowers). The velocity profile was obtained using a 5-hole pitot tube by the non-nulling method. The two stage axial flow fan configurations for the optimal operation conditions were set by using the experimental results for the single rotating axial flow fan and the single stage axial flow fan. The single rotating axial flow fan showed relatively low efficiency due to the swirl velocities behind rotor exit which produced pressure losses. In contrast, the single stage and the two-stage axial flow fans showed performance improvements due to the swirl velocity reduction by the stator. The peak efficiency of the two stage axial flow fan was improved by 21% and 6%, compared to the single rotating axial flow fan and the single stage axial flow fan, respectively.

A Study on Two Stage PFC Full-Bridge Converter with a Single PWM Controller (단일 PWM 제어기에 의한 역률보상 이단 풀 브리지 컨버터에 관한 연구)

  • Jeon, Joon-Sang;Kim, Yong;Kwon, Soon-Do;Kim, Pil-Soo;Yoon, Suk-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.368-371
    • /
    • 2000
  • Two-stage power factor correction (PFC) converter with a single PWM controller is proposed. It consists of a power factor pre-regulator cascaded by an isolated DC/DC converter as in a conventional two-stage approach. However, a single PWM controller is used as in a single-stage, single-switch PFC approach. This converter gives the goof power factor correction, low line current harmonic distortions, and tight output voltage regulations. This converter also has a high efficiency by employing an soft switching method. The proposed approach has advantages such as high performance over the single-stage approach and low cost over two-stage approach. The experimental results obtained on a 300W (30V/10A) prototype PFC converter are given to verify the effectiveness of the proposed control method.

  • PDF

Modified RCC MPPT Method for Single-stage Single-phase Grid-connected PV Inverters

  • Boonmee, Chaiyant;Kumsuwan, Yuttana
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1338-1348
    • /
    • 2017
  • In this study, a modified ripple correlation control (RCC) maximum-power point-tracking (MPPT) algorithm is proposed for a single-stage single-phase voltage source inverter (VSI) on a grid-connected photovoltaic system (GCPVS). Unlike classic RCC methods, the proposed algorithm does not require high-pass and low-pass filters or the increment of the AC component filter function in the voltage control loop. A simple arithmetic mean function is used to calculate the average value of the photovoltaic (PV) voltage, PV power, and PV voltage ripples for the MPPT of the RCC method. Furthermore, a high-accuracy and high-precision MPPT is achieved. The performance of the proposed algorithm for the single-stage single-phase VSI GCPVS is investigated through simulation and experimental results.

Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System (단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석)

  • Tian, Huaizhang;Park, Seong-Ryong
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

Comparative Study of the Latissimus Dorsi and Gracilis Muscle Reconstruction for Reanimation of a Paralyzed Face (안면 마비의 재건에서 광배근 유리피판과 박근 유리피판의 비교 연구)

  • Kang, Dong Hee;Lim, Chan Su;Koo, Sang Hwan;Park, Seung Ha
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.336-341
    • /
    • 2007
  • Purpose: The most accepted method for the reanimation of a paralyzed face is the two-stage method that combines cross-face nerve grafting with free-muscle transfer. Although the results of reconstruction with this method are satisfactory, there is an excessive delay between the stages, which prolongs the period of rehabilitation. In order to overcome this drawback, a one- stage, neurovascular free-flap reconstruction method using free neurovascular muscle flaps is introduced. Methods: From 1994 to 2004, 35 patients with longstanding facial palsy were treated. Fifteen patients underwent the single-stage reconstruction with the latissimus dorsi muscle, and 20 patients underwent the two-stage reconstruction method with the gracilis muscle. We compared the long-term results of the two methods of reconstruction. The mean follow-up period was 28.7 months for one-stage reconstruction, and 35.2 months for the two-stage, respectively. Results: In the patient group of the single stage reconstruction, both mouth corner excursion and animation grade were markedly improved at the final postoperative visit. Moreover, the first muscle contraction occurred earlier in this group, than in the two-stage reconstruction group. However, four patients in the single stage group never achieved a first muscle contraction or mouth corner excursion. Conclusion: Facial palsy is a very challenging condition for cosmetic surgeons to deal with. Traditional methods for treatment of chronic facial palsy use a two-stage muscle flap which is time-consuming and burdensome to patients, many of whom are averse to waiting 8 to 12 months to complete the two stages. The one-stage reconstruction method described herein uses a latissimus dorsi free-flap and has demonstrated consistent positive outcomes in clinical assessments.

Controller Design of Piezoelectric Milliactuator for Dual Stage System (이중 구동 시스템을 위한 압전 밀리엑츄에이터의 제어기 설계)

  • Hong, Eo-Jin;Yoon, Joon-Hyun;Park, No-Cheal;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.46-51
    • /
    • 2001
  • To reach high areal density, less track pitch is expected and more servo bandwidth is required. One approach to overcoming the problem is by using dual stage servo system. In this system, a voice coil motor (VCM) is used as the primary stage while a milliactuator is used as the secondary stage. We have suggested new milliactuator based on the shear mode of piezoelectric elements to drive the head suspension assembly. In this paper, we introduce controller design method, PQ method. PQ method reduces the controller design problem for DISO(dual-input/single-output) systems to two standard controller design problems for SISO(single-input/single-output) problems. The first part of PQ method directly address the issue of actuator output contribution, and the second part allows the use of traditional loop shaping to achieve the overall system performance. This paper shows how to employ the PQ method to meet aggressive close-loop performance specifications for a disk drive system with a VCM and piezoelectric milliactuator.

  • PDF

The Method of Reducing the Output Electrolytic Capacitance in Single Stage PFC flyback Converter (Single stage PFC flyback 컨버터의 전해커패시터용량저감기법)

  • Kim, Jin-Gu;Park, Chong-Yeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.81-88
    • /
    • 2015
  • LED has been great attentions in lighting industry because of its long life-time, high efficiency, excellent light output characteristics. However, the life-time of the LED driving system is decreased because of the electrolytic capacitor which is used in the power conversion system for driving LED lighting. Therefore the capacitance reduction methods have been studied to replace an electrolytic capacitor with film or tantalum capacitor. This paper presents the Single stage PFC flyback converter with the simplified third harmonic current injection circuit to reduce output capacitance and the proposed system is theoretically analyzed and verified through the experiment.

A Study on PFC of Active Clamp ZVS Flyback Converter (능동 클램프 ZVS 플라이백 컨버터의 역률개선에 관한 연구)

  • 최태영;류동균;이우석;안정준;원충연;김수석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.49-57
    • /
    • 2001
  • This paper analyzed PFC of active clamp ZVS flybark converter by adding two method PFC (Power Factor Correction) circuit-two-stage and single-stage. The addition of active clamp circuit also provide a mechanism fur achieving ZVS of both the primary and auxiliary switches. ZVS also limits the turn off di/dt of the output rectifier, reducing rectifier switching loss and switching noise, due to diode reverse recovery. As a results, the proposed converters have characteristics of the reduced switching noise and high efficiency in comparison to conventional flyback converter. The simulation and experimental results show that the proposed converters improve the input PF of 300[W] ZVS flyback converter by adding single-stage two-stage PFC circuit.

  • PDF

Two-stage & Single-stage Power Factor Correction circuits for Single-phase Power source (단상전원에 적합한 단일단 및 2단 역률개선회로)

  • Kim Chert-Jin;Yoo Byeong-Kyu;Kim Choong-Sik;Kim Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1214-1216
    • /
    • 2004
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic contents. Typically, these SMPS have a power factor lower than 0,65. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. PFC circuit have tendency to be applied in new power supply designs. The input active power factor correction circuits can be implemented using either the two-stage or the single-stage approach. In this paper, the comparative analysis of power factor correction circuit using feedforward control with average current mode single-stage flyback method converter and two-stage converter which is combination of boost and flyback converter. The two prototypes of 50W were designed and tested a laboratory experimental. Also, the comparative analysis is confirmed by simulation and experimental results.

  • PDF