• Title/Summary/Keyword: solid phase extraction disk

Search Result 7, Processing Time 0.025 seconds

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

A Study on the Separation and Extraction of Polycyclic Aromatic Hydrocarbons in Water Sample by Gas Chromatography/Mass Spectrometry (기체크로마토그래피/질량분석법에 의한 물시료 중 Polycyclic Aromatic Hydrocarbons의 분리 및 추출에 관한 연구)

  • Lee, Won;Hong, Jee-Eun;Park, Song-Ja;Pyo, Hee Soo;Kim, In-Whan
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.321-331
    • /
    • 1998
  • The separation and sample extraction methods of 19 polycyclic aromatic hydrocarbons (PAHs) in water samples were investigated by gas chromatography/mass spectrometry (GC/MS) and some extraction methods involved liquid-liquid extraction, disk extraction and solid-phase extraction methods. The separation of 19 PAHs was possible by partial variation of oven temperature of GC/MS in temperature range $80{\sim}310^{\circ}C$. Extraction procedures of PAHs in water samples were somewhat modified and compared as extraction recoveries and the simplicity of methods. Extraction recoveries of PAHs were 71.3~109.5% by liquid-liquid extraction method. By using disk extraction, good extraction recoveries (80.7~94.9%) were obtained in case of $C_{18}$ disk extraction method by filtration. And extraction recoveries of PAHs by $C_{18}$ solid-phase were in the range of 51.8~77.9%. Method detection limits (S/N=5) of 19 PAHs were in the range of 0.25~6.25 ppb by liquid-liquid extraction and solid-phase extraction and 0.05~1.25 ppb by disk extraction methods.

  • PDF

Fast Analytical Method of PCDD/Fs in Water by Combination of Disk Type Solid Phase Extraction and Column Coupling Chromatography (디스크타입 고상추출장치 및 컬럼커플링을 이용한 물시료의 PCDD/Fs 간이분석법)

  • Choi, Jae-won;Moon, Bu-shik;Kim, Kyoung-sim;Kim, Jung-hee;Kim, Sun-heong;Baek, Kyung-hee
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.879-886
    • /
    • 2006
  • The analytical methods of polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans (PCDD/Fs) for water sample with extremely low concentration was developed to extract large volume and to improve fast chromatography for clean up. Semi-automated solid phase extraction (SPE) system and column coupling chromatography using elution pump was optimized and applied to each processes of treatment plant. Results of disk type SPE indicated that this system was applicable below 40 L of aqueous sample with a flow rate of 0.08 ~ 0.2 L/min. Average recoveries of SPE using labeled sampling spike of $^{37}Cl$-2,3,7,8-TCDD was 97%. Column coupling method resulted in reduced clean up time, solvent volume, increased average recoveries with constant elution rate. The combined methods were applied to the monitoring of drinking water treatment plant. Limits of detection (LOD) of each process were calculated. For example, LOD of raw and treated water ranged 0.094~0.968 pg/L and 0.028~0.364 pg/L, respectively. Combined methods of extraction and cleanup techniques provided fast analysis of PCDD/Fs with high accuracy and low LODs for water samples.

Flame Atomic Absorption Spectrometric Determination of Ultra Traces of Thallium(I) ion after Solid Phase Extraction by Octadecyl Silica Membrane Disk Modified by a New Schiff Base

  • Mashhadizadeh, Mohammad Hossein;Moatafavi, Ali;Allah-Abadi, Hossein;Zadmehr, Mohammad Reza
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.9
    • /
    • pp.1309-1313
    • /
    • 2004
  • A simple and reliable method has been developed to selectively separate and concentrate trace amounts of thallium ion from real samples for the subsequent measurement by flame atomic absorption spectrometry (FAAS). Thallium ions are absorbed quantitatively during passage of aqueous real samples through an octadecyl bonded silica membrane disk modified by 4-(4-Chloro-phenylazo)-2-[(4-hydroxy-phenylamino)-methyl]-phenol. The retained $Tl^+$ ions are then stripped from the disk quantitatively with a minimal amount of thiosulfate solution as eluent. The proposed method permitted large enrichment factors of about 130 and higher. The relative standard deviation for ten replicate extraction of thallium from 1 L samples containing 5 ${\mu}g$ thallium is 1.2%. The break through volume for 5 ${\mu}g$ thallium is 1000 mL. The limit of detection of the proposed method is 11.2 ng of $Tl^+$ per 1000 mL. The effects of various cationic interferences on the recovery of thallium in binary mixtures were studied. The method was applied to the recovery of $Tl^+$ ions from natural water and human hair samples.

A Solid-Phase Extraction Method for Analyzing Trace Amounts of Polychlorinated Dibenzo-p-Dioxins and Dibenzofurans in Waste Water

  • Park, Deok-Hie;Youn, Yeu-Young;Choi, Jae-Won;Lim, Young-Hee;Cho, Hye-Sung
    • Mass Spectrometry Letters
    • /
    • v.2 no.1
    • /
    • pp.12-15
    • /
    • 2011
  • The Korean government has regulated emission of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in waste water of manufacturing facilities producing chlorinated compounds since 2009. As this regulation is expected to be reinforced in 2013 to 50 pg I-TEQ/L, a large sample volume is required for the analysis of trace amounts of PCDD/Fs in waste water. Liquid-liquid extraction (LLE) is used to extract PCDD/Fs from aqueous samples; however, its low efficiency makes it inadequate for analyzing large sample volumes. Herein, we present a disk-type solid-phase extraction (SPE) method for the analysis of dioxin at a part per quadrillion level in waste water. This SPE system contains airtight glass covers with a decompression pump, which enables continuous semi-automated extraction. Small (0.5 L) and large (7 L) samples were extracted using LLE and SPE methods, respectively. The method detection limits (MDLs) were 0.001.0.25 and 0.015.4.1 pg I-TEQ/L for the SPE and LLE methods, respectively. The concentrations of detected congeners with both methods were similar. However, the concentrations of several congeners that were not detected with the LLE method were quantified using the SPE method.

Determination of hazardous semi-volatile organic compounds in industrial wastewater using disk-type solid-phase extraction and GC-MS (디스크형 고상 추출법과 GC/MS를 이용한 공장폐수 중 반휘발성유기화합물질 분석)

  • Lee, In-Jung;Lim, Tae-Hyo;Heo, Seong-Nam;Nam, Su-Gyeong;Lee, Jae-Gwan;Cheon, Se-Uk
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.236-241
    • /
    • 2012
  • There are many industrial factories in the central Nakdong river basin and have been occurred water pollution accidents by hazardous chemicals such as phenol, 1,4-dioxane and perchlorate. In this study, ten compounds of semi-volatile organic compounds (SVOCs) (dichlorvos, toluene-2,4-diisocyanate, 4,4'-methylenedianiline, 4,4'-methylenebis (2-chloroaniline), diethyl phthalate, di-n-butyl phthalate, butyl benzyl phthaltate, bis (2-ethylhexyl) adipate, benzophenone, 4,4'-bisphenol A) of hazardous chemicals which may be potentially discharged into the Nakdong river, were determined by gas chromatography-mass spectrometry (GC-MS) with disk-type solid-phase extraction. Accuracy and precision were in the range of 75.6~110.5%, and 4.6~12.7%, respectively and recovery was in the range of 72.4~127.9%. Three compounds (bis (2-ethylhexyl)adipate, benzophenone, 4,4'-bisphenol A) were detected in industrial wastewater such as wastewater treatment plants (WWTPs) and wastewater discharge facilities in the Nakdong River basin.

The Extraction and Derivatization of Organotins in Water Sample by Gas Chromatograph/Mass Spectrometer (기체크로마토그래프/질량분석기에 의한 물시료 중 Organotin의 추출 및 유도체 반응에 관한 연구)

  • Hong, Jee-Eun;Lee, Kang-Jin;Pyo, Hee Soo;Park, Song-Ja;Lee, Won
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.636-645
    • /
    • 2000
  • A method is described for the determination of organotins in water samples by GC/MS. Optimized derivatization methods for ethylation and hydrogenation of organotins were surveyed according to various reaction conditions such as time, pH and concentration of reagents. The organotins were extracted with n-hexane in presence of 0.1% tropolone and hydrogenated with sodium borohydride. Extraction recoveries of organotins with hydrogenation were in the range of 61-112%. After ethylation, organotins in water samples were extracted by liquid-liquid extraction (LLE) and solid-phase extraction (SPE). Using LLE, extraction recoveries were in the range of 74-113%. The recoveries ranged from 61-97% in the case of SPE with styrene-divinylbenzene copolymers. Method detection limits of hydrogenated and ethylated organotins ranged from 0.05 to 0.5 ng/ml and from 0.02 to 0.05 ng/ml, respectively.

  • PDF