• Title/Summary/Keyword: solid-phase fluorescence immunoassay

Search Result 5, Processing Time 0.022 seconds

Application of a solid-phase fluorescence immunoassay to determine neomycin residues in muscle tissue of olive flounder (Paralichthys olivaceus), rockfish (Sebastes schlegeli), and red sea bream (Pagrus major)

  • Jung, Won Chul;Chung, Hee Sik;Shon, Ho Yeong;Lee, Hu-Jang
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.2
    • /
    • pp.175-179
    • /
    • 2008
  • Parallux, a solid-phase fluorescence immunoassay (SPFIA) developed for detection antibiotics residue in milk, was applied for analysis of antibiotics in muscle tissue of olive flounder (Paralichthys olivaceus), rockfish (Sebastes schlegeli), and red sea bream (Pagrus major). Fishes were dipped in neomycin 140 mg/ton water, the recommended therapeutic dose, for 24 h. Muscle samples were obtained on 1st, 2nd, 3rd, 4th and 5th day after drug treatment. The concentration of neomycin in muscle was determined using an internal standard (100 ppb as neomycin). The absorbance ratio of sample to internal standard (S/C) was employed as an index to determine the muscle residues in fishes. To investigate the recovery rate, the standard solutions were added to muscle samples to give final concentrations in muscle of 0.2 and 0.5 mg/ml. The recovery rates of all spiked samples were > 85% of the spiked value. Neomycin was detected in muscles of fishes treated after the 1st day of withdrawal period. On the 2nd day after drug treatment, all muscle samples showed negative reaction (S/C ration ${\leq}$ 1.0). The present study showed that the SPFIA can be applied for predicting residues of neomycin in muscle tissues of farmed fishes.

Application of a solid-phase fluorescence immunoassay to determine ampicillin residues in muscle tissue of olive flounder (Paralichthys olivaceus)

  • Jung, Won Chul;Ha, Ji Young;Chung, Hee Sik;Heo, Sung Hyeok;Kim, Suk;Lee, Hu Jang
    • Korean Journal of Veterinary Research
    • /
    • v.46 no.3
    • /
    • pp.291-294
    • /
    • 2006
  • $Parallux^{TM}$, a solid-phase fluorescence immunoassay(SPFIA) developed for antibiotics residue detection in milk, was applied for analysis of fish muscle. The recommended therapeutic dose of ampicillin(100 mg/kg body weight, withdrawal period 7 days) was orally administered to a group of 25 olive flounders(Paralichthys olivaceus) for consecutive five days. Muscle was sampled after drug treatment 1st, 2nd, 3rd, 4th and 5th day. The concentration of ampicillin in muscle, determined by SPFIA, was compared with that of internal standard(10 ppb as ampicillin). The absorbance ratio of sample to internal standard(Bs/Bo) was employed as an index to determine the muscle residue in olive flounder. To investigate the recovery rate, the standard solutions were added to muscle samples to give final concentrations in muscle of 10 and 50 ng/ml. The recovery rates of all spiked samples were > 89% of the spiked value. Ampicillin was detected in muscle of fishes treated until the 3rd day of withdrawal period. The present study showed that the SPFIA can be easily adopted in predicting tissue residues for ampicillin in farmed fishes.

Application of a solid-phase fluorescence immunoassay to determine streptomycin residues in muscle tissue of olive flounder (Paralichthys olivaceus), rockfish (Sebastes schlegeli), and red sea bream (Pagrus major)

  • Chung, Hee Sik;Kim, Suk;Chun, Myung Sun;Jung, Won Chul;Kim, Dong Hyeok;Shon, Ho Yeong;Lim, Jeong Ju;Lee, Hu-Jang
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.2
    • /
    • pp.241-245
    • /
    • 2007
  • Parallux (IDEXX Laboratories, USA), a solid-phase fluorescence immunoassay (SPFIA) developed for antibiotics residue detection in milk, was applied for analysis of antibiotics in muscle tissue of olive flounder (Paralichthys olivaceus), rockfish (Sebastes schlegeli), and red sea bream (Pagrus major). Fishes were dipped in streptomycin 20 g/ton water, the recommended therapeutic dose, for 3 consecutive days. Muscle was sampled after 1st, 2nd, 3rd, 4th and 5th day drug treatment. The concentration of streptomycin in muscle, determined by SPFIA, was compared with that of internal standard (200 ppb as streptomycin). The absorbance ratio of sample to internal standard (S/C) was employed as an index to determine the muscle residues in fishes. The standard solutions were added to muscle samples to give final concentrations in muscle of 0.2 and 0.5 mg/ml to investigate the recovery rate. The recovery rates of all spiked samples were > 84% of the spiked value. Streptomycin was detected in muscles of fishes treated after the 1st day of withdrawal period. The present study showed that the SPFIA can be easily adopted in predicting muscle tissue residues for streptomycin in farmed fishes.

Development of an Open Sandwich Fluoroimmunoassay Based on FRET (FRET에 기반한 Open Sandwich Fluoroimmunoassay)

  • Wei, Quande;Lee, Moon-Kwon;Seong, Gi-Hun;Choo, Jae-Bum;Lee, Eun-Kyu
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.426-432
    • /
    • 2007
  • We have developed a sensitive, one-step, homogeneous open sandwich fluoroimmunoassay (OsFIA) based on fluorescence resonance energy transfer (FRET) and luminescent semiconductor quantum dots (QDs). In this FRET assay, estrogen receptor-$\beta$ (ER-$\beta$) antigen was incubated with QD-labeled anti-ER-$\beta$ monoclonal antibody and AF (Alexa Fluoro)-labeled anti-ER polyclonal antibody for 30 minutes, followed by FRET measurement. The dye separation distance was estimated to be between $80\sim90\;{\AA}$. The present method is rapid, simple and highly sensitive, and did not require the bound/free reagent separation steps and solid-phase carriers. A concentration as low as 0.05 nM (2.65 ng/ml) receptor was detected with linearity ($R^2$ > 0.990). In addition, the assay was performed with commercial antibodies. This assay provides a convenient alternative to conventional, laborious sandwich immunoassays.

Analysis of Methamphetamine and Amphetamine in Oral Fluid of Eleven Drug Abusers (마약남용자 11명의 타액 중 메스암페타민의 분석)

  • Kim, Eun-Mi;Lee, Ju-Seon;Choi, Hye-Young;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.419-425
    • /
    • 2008
  • A qualitative and quantitative analytical method was developed for detection of methamphetamine (MA) and its main metabolite amphetamine (AM) in oral fluid. Oral fluids of eleven drug abusers were provided by Police, specimens were collected by stimulation with a cotton swab treated with 20 mg of citric acid ($Salivette^{(R)}$; Sarstedt, USA). As the preliminary test, oral fluid samples were screened for amphetamines by Fluorescence Polarization Immunoassay (TDxFLx, Abbott Co.). Extraction for MA was performed using solid-phase extraction (SPE) by $RapidTrace^{TM}$ (Zymark, USA) with mixed mode cation exchange cartridge, CLEAN $SCREEN^{(R)}$ (130 mg/3 ml, UCT) after dilution with phosphate buffer. Samples were evaporated and derivatized by pentafluoropropionic acid anhydride (PFPA). Quantitation of MA and AM was performed by gas chromatography-mass spectrometry (GC-MS) using selective ion monitoring (SIM), the quantitation ions were m/z 204 (MA), 208 (MA-$D_5$), 190 (AM) and 194 (AM-$D_5$). The selectivity, linearity of calibration, limit of detection (LOD) and quantification (LOQ) within- and between day precision, accuracy and recoveries were examined as parts of the method validation. All oral fluid samples gave positive results to immunoassay for MA (cut-off level, 50 ng/ml as d-amphetamine). Concentrations of MA and AM by GC-MS in eleven samples were ranged 104.2${\sim}$4603.3 ng/ml and 32.4${\sim}$268.6 ng/ml, respectively. Extracted calibration curves of MA and AM were linear over the two concentration range of 1${\sim}$100 and 50${\sim}$1000 ng/ml with correlation coefficient of above 0.999. LOQ of MA and AM was 1 and 3 ng/ml, respectively. The intraand inter-day run precisions (CV) for MA and AM were less than 10%, and the accuracies (bias) for MA and AM were also less than 10% at the two different concentrations 5 and 100 ng/ml at low calibration range, 50 and 1000 ng/ml at high calibration range. The absolute recoveries of MA and AM at low and high calibration ranges were more than 82% and 75%, respectively. In this study the qualitative and quantitative analytical method of MA in oral fluid was established. Oral fluid testing may detect drug use in past hours because of its shorter detection window than urine, and be useful in post-accident situations. So oral fluids will be most useful for testing drug abuse in the driving under the influence of drug (DUID) as the alternative specimens of urine.