• 제목/요약/키워드: spacing limit

검색결과 85건 처리시간 0.035초

일차원 액적 배열의 화염 퍼짐에 있어서 연료의 혼합 효과에 관한 연구 (A Study on Blend Effect of Fuel in Flame Spread Along An One-Dimensional Droplet Array)

  • 박정;소림수소;신강숭
    • 한국연소학회지
    • /
    • 제3권2호
    • /
    • pp.1-11
    • /
    • 1998
  • Experimental investigation on flame spread of blended fuel droplet arrays has been conducted for droplet diameters of 1.0mm and 0.75mm using high-speed chemiluminescence images of OH radical. The flame spread rate is measured with blended fuel composition, droplet diameter, and droplet spacing. Flame spread is categorized into two: a continuous mode and an intermittent one. There exist a limit droplet spacing, above which flame does not spread, and a droplet spacing of maximum flame spread, which is closely related to flame diameter. It is seen that flame spread rate is mainly dependent upon the relative position of flame zone within a droplet spacing. In case of large droplet, the increase of % volume of Heptane induces the shift of limit droplet spacing to a larger spacing since volatile Heptane plays a role of an enhancer of flame spread rate. In case of small droplet, the increase of % volume of Heptane leads to the shift of limit droplet spacing to a smaller droplet spacing. This is so because of the delayed chemical reaction time by the rapid increase of mass flux of fuel vapor for small droplet.

  • PDF

Shear Tests for Ultra-High Performance Fiber Reinforced Concrete (UHPFRC) Beams with Shear Reinforcement

  • Lim, Woo-Young;Hong, Sung-Gul
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권2호
    • /
    • pp.177-188
    • /
    • 2016
  • One of the primary concerns about the design aspects is that how to deal with the shear reinforcement in the ultra-high performance fiber reinforced concrete (UHPFRC) beam. This study aims to investigate the shear behavior of UHPFRC rectangular cross sectional beams with fiber volume fraction of 1.5 % considering a spacing of shear reinforcement. Shear tests for simply supported UHPFRC beams were performed. Test results showed that the steel fibers substantially improved of the shear resistance of the UHPFRC beams. Also, shear reinforcement had a synergetic effect on enhancement of ductility. Even though the spacing of shear reinforcement exceeds the spacing limit recommended by current design codes (ACI 318-14), shear strength of UHPFRC beam was noticeably greater than current design codes. Therefore, the spacing limit of 0.75d can be allowed for UHPFRC beams.

피복두께와 콘크리트 강도를 고려한 철근콘크리트 인장부재의 균열간격 (Crack Spacing in RC Tension Members Considering Cover Thickness and Concrete Compressive Strength)

  • 김우;이기열
    • 대한토목학회논문집
    • /
    • 제38권2호
    • /
    • pp.193-202
    • /
    • 2018
  • 이 연구는 철근콘크리트 부재에서 사용한계상태 검증 및 내구성능 평가의 요소인 균열폭을 계산하는데 중요한 변수가 되는 균열간격 계산식을 제안한 것이다. 철근콘크리트 부재의 균열거동 해석을 위한 지배방정식이 되는 부착특성을 반영하여 평균균열간격 기본식을 유도하고, 피복두께와 콘크리트 강도의 영향을 고려할 수 있도록 여러 연구자들이 수행한 124개의 직접인장실험에서 측정된 균열간격을 분석하여 각각의 계수를 제안하였다. 그리고, 최대 및 평균 균열간격이 동시에 측정된 80개의 실험체 자료로부터 상관관계 분석을 실시하여 평균균열간격으로부터 최대 균열간격을 간편하게 예측할 수 있는 상관계수를 제안하였다. 제안된 평균균열간격 계산식 및 최대균열간격 상관식에 대해서 현행 설계기준의 규정과 비교를 실시하였다. 비교 결과, 평균균열간격 및 최대균열간격에 대한 제안식은 콘크리트구조기준 및 도로교설계기준(한계상태설계법)의 해당 규정과 비교하여 예측의 정확성 및 신뢰도가 개선됨을 확인하였다.

기계식 연속철근콘크리트포장의 현장 적용성 및 거동 분석 연구 (Field Application and Performance of Continuously Reinforced Concrete Pavement via Mechanical Tube-feeding Method)

  • 최훈석
    • 한국도로학회논문집
    • /
    • 제18권2호
    • /
    • pp.43-49
    • /
    • 2016
  • PURPOSES : The field application and performance of continuously reinforced concrete pavement (CRCP), constructed by using the mechanical tube-feeding method, are evaluated in this study. METHODS: The location of the rebar was evaluated by using the MIRA system. The early-age CRCP performance was evaluated via visual survey, in which the crack spacing and crack width were examined. RESULTS: The location of longitudinal reinforcing bars was evaluated via MIRA testing and the results showed that the longitudinal rebars all lie within a given tolerance limit (${\pm}2.5cm$) of the target elevation. In addition, owing to the low temperature when the concrete was pured, the crack spacing in the Dae-Gu direction is slightly wider than that of the Gwang-Ju direction. Almost all of the crack spacings lay within the range of 1.0 m~3.0 m. A crack width of <0.3 mm was measured at the pavement surface. However, as revealed by the field survey, the crack spacing was not correlated with the crack width. CONCLUSIONS : In CRCP constructed by using the mechanical tube-feeding method, almost all of the longitudinal reinforcing bars lay within the tolerance limit (2.5 cm) of the target elevation. The concrete-placing temperature affects the crack spacing, owing to variations in the zero-stress temperature. Crack survey results show that there is no correlation between the crack spacing and crack width in CRCP.

과전류에 의해 단락된 전선의 결정성장 특성에 관한 연구 (Study of the Characteristics and Crystal Growth of a shorted Wire by Overcurrent)

  • 박진영;방선배;고영호
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.83-90
    • /
    • 2017
  • 전선에 정격이상의 과전류가 흐르게 되면 온도가 상승하고 전선피복이 열화되어 단락현상이 발생한다. 과전류의 크기에 따라 전선의 온도 상한치는 변화하며, 각각의 온도 상한치에서 단락이 발생할 때, 단락온도와 전선표면온도간 온도차로 인해 응고과정에서 냉각속도 차이가 발생한다. 이때 용융단면에 형성되는 수지상 조직의 패턴특징이 상이하게 된다. 본 논문에서는 과전류 크기에 따라 변화하는 전선온도의 상한치를 측정하고, 이때 단락을 발생시켜 수지상의 2차 가지 간격(Dendrite Arm Spacing : DAS)을 분석하여 수치를 정량화 하였다. 실험결과, 과전류 크기가 커짐에 따라 전선온도의 상한치는 증가하였으며, 전선온도가 높아질수록 2차 가지 간격이 증가하는 것을 확인하였다.

콘크리트 내부공극 분석을 위한 행렬간격계수 모델식의 제안 (Proposal of Matrix Spacing Factor for Analyzing Air Void System in Hardened Concrete)

  • 정원경;전인구;김용곤;이봉학
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.679-682
    • /
    • 2004
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance. Linear traverse method and point count method described at ASTM is the routine analysis of the air void system that have been widely used to estimate the spacing factor in hardened concrete. Recently, many concretes often have a spacing factor higher than the generally accepted $200-250{\mu}m$ limit for the usual range of air contents. This study is proposed to estimate the matrix spacing factor by calculation of simplicity. The matrix spacing factor needs two parameters that are air content and numbers of air voids in the hardened concrete. Those are obtained from the standard air-void system analysis of the ASTM C 457. The equation is valid for all values of paste-to-air ratio because the estimation of paste content is unnecessary at the using ASTM C 457. The matrix spacing factor yields a similar estimate of the standard spacing factor.

  • PDF

온도하중을 고려한 인터모달 터미널 플랫폼의 설계 검토 (Design Review of Inter-Modal Terminal Platform for Temperature Load)

  • 김경수;김다애;김흥래;현은택
    • 한국전산구조공학회논문집
    • /
    • 제32권5호
    • /
    • pp.305-311
    • /
    • 2019
  • 본 연구에서는 국내에 새롭게 도입하고자 하는 인터모달 자동화물운송 시스템을 구현하기 위한 터미널 플랫폼 시설의 온도하중에 따른 적정 신축이음 간격을 살펴보았다. 터미널 플랫폼의 적정 신축이음 간격 검토는 미국 F.C.C.(federal construction council)에서 제안한 식을 이용하여 지역별 온도변화에 따른 최대 신축이음 간격을 설정하고, 구조해석 프로그램을 통해서 산출된 최대 변위값과 건축구조 수평변위 제한값을 비교하였다. 적정 신축이음 간격은 온도변화로 인한 구조물 최대 변위량이 수평변위 제한값 이하가 되는 슬래브 길이로 선정하였으며, F.C.C 제안식을 통하여 산정한 지역별 최대 신축이음 간격을 적용하여 구조물 최대 발생 변위를 살펴본 결과, 건축구조 수평변위 제한값 이내에서 발생될 수 있는 최대변위 값을 확인할 수 있었다.

3D stability of pile stabilized stepped slopes considering seismic and surcharge loads

  • Long Wang;Meijuan Xu;Wei Hu;Zehang Qian;Qiujing Pan
    • Geomechanics and Engineering
    • /
    • 제32권6호
    • /
    • pp.639-652
    • /
    • 2023
  • Stepped earth slopes incorporated with anti-slide piles are widely utilized in landslide disaster preventions. Explicit consideration of the three-dimensional (3D) effect in the slope design warrants producing more realistic solutions. A 3D limit analysis of the stability of pile stabilized stepped slopes is performed in light of the kinematic limit analysis theorem. The influences of seismic excitation and surcharge load are both considered from a kinematic perspective. The upper bound solution to the factor of safety is optimized and compared with published solutions, demonstrating the capability and applicability of the proposed method. Comparative studies are performed with respect to the roles of 3D effect, pile location, pile spacing, seismic and surcharge loads in the safety assessments of stepped slopes. The results demonstrate that the stability of pile reinforced stepped slopes differ with that of single stage slopes dramatically. The optimum pile location lies in the upper portion of the slope around Lx/L = 0.9, but may also lies in the shoulder of the bench. The pile reinforcement reaches 10% universally for a looser pile spacing Dc/dp = 5.0, and approaches 70% when the pile spacing reaches Dc/dp = 2.0.

재료 특성 변화에 따른 철근콘크리트 휨부재의 간접균열제어 방법 연구 (Indirect Crack Controling Method Affected by Variation of Material Characteristics in Reinforced Concrete Flexural Members)

  • 최승원;김우
    • 콘크리트학회논문집
    • /
    • 제23권1호
    • /
    • pp.87-98
    • /
    • 2011
  • 철근콘크리트 부재의 균열은 필수불가결한 현상이다. 따라서 효과적으로 균열폭을 측정하기 위한 많은 경험식이 제시되었고, 또한 간편한 적용성 때문에 철근 간격과 직경의 제어를 통한 간접균열제어법이 제시되고 널리 사용되고 있다. EC2에서는 최대균열간격과 평균변형률의 곱으로 설계 균열폭을 산정한다. 이 연구에서는 재료 특성에 따른 최대철근간격과 최대철근직경을 산정하였다. 특히 인장증강효과 모델과 최대균열간격에 따른 영향을 분석하였고, 이를 콘크리트구조설계기준에서 제시한 값과 비교하였다. 해석 결과 인장증강효과 모델에 따라 큰 차이가 발생하였고, 2차식 형태의 인장증강효과 모델과 Part II의 최대균열간격을 사용함으로써 과소평가되었다. 따라서 2차식 형태의 인장증강효과 모델을 사용함으로써 합리적인 간접균열제어가 가능하다. 또한 이를 통해 휨부재의 사용성 검증에 일관성을 확보할 수 있을 것으로 판단된다. 이와 함께 균열제어를 위한 두 가지 모델을 제안하였다.

일차원 액적 배열하에서 화염 퍼짐에 관한 실험적 연구 (An Experimental Study on Flame Spread in an One-Dimensional Droplet Array)

  • 박정;신현동;코바야시 히데아키;니오카 다카시
    • 대한기계학회논문집B
    • /
    • 제23권1호
    • /
    • pp.131-139
    • /
    • 1999
  • Experimental investigations on flame spread in droplet arrays have been conducted under supercritical ambient pressures of fuel droplet. Flame spread rates are measured for n-Decane droplet of diameters of 0.75 and 1.0mm, using high speed images of OH chemiluminescence up to 3.0MPa. The pattern of flame spread is categorized into two: a continuous mode and an intermittent one. There exists a limit droplet spacing, above which flame spread does not occur. Flame spread rate with the decrease of droplet spacing increases and then decreases after takin& a maximum. It is also seen that there exists a limit ambient pressure, above which flame spread does not occur. Flame spread rate decreases monotonically with the increase of ambient pressure. Exceptionally, In the case of a small droplet spacing, flame spread with the increase of ambient pressure is extended to supercritical pressures of fuel droplet. This is caused by enhanced vaporization with the increase of ambient pressure. Consequently, in flame spread with droplet droplet spacing, the relative position of flame to droplet spacing plays an important role. The monotonic decrease with ambient pressure is mainly related to the reduction of flame radius in subcritical pressures and the extension to supercritical pressures of flame spread is caused by the reduction of ignition time of unburnt droplet due to the enhanced vaporization at supercritical pressures.