• Title/Summary/Keyword: step-down

Search Result 641, Processing Time 0.036 seconds

Transformation Characteristics of Multi layed Ring-dot type Piezo Transformer (적층형 Ring-dot type 압전변압기의 변압특성)

  • Chong, Hyon-Ho;Park, Tae-Gone;Kim, Myong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.671-674
    • /
    • 2004
  • This paper presents design and analysis of multi-layered ring-dot type piezoelectric transformer. These transformers are useful for step up and step down. The transformers consist of disk type multi-layered piezoelectric ceramic plates. The finite element method(FEM) was used for analysis transformer. Vibration mode, electric field and equivalent elastic strain of piezoelectric transformer were simulated by changing frequency. As results, the strain was distributed in isolation part entirely. We can get the operated in step up transformer when the inner side electrode using by input parts. Also we can get the step down transformers using by input Part as outer side electrode. The step up ratio and step down ratio was increased by decreasing inner side electrode. The resonance frequency was increased by increasing inner side electrode when the transformer was operated in step down transformer. But the step up one was decreased. From these results, we can expect to multi-layered ring-dot type piezo transformers as step up and step down transformers.

  • PDF

A COMPARISON OF APICAL SEAL FOLLOWING "STEP-DOWN/BALANCED FORCE" AND "STEP-DOWN/STEP-BACK" ROOT CANAL SHAPING (Balanced Force와 Step-Back 근관성형후 치근단 폐쇄효과의 비교연구)

  • Lee, Yun-Hee;Kim, Jong-Hwa;Son, Ho-Hyun;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.780-788
    • /
    • 1995
  • The purpose of this study was to compare the apical seal following root canal shaping by different methods. From fourty extracted mandibular 1st and 2nd molars, fourty mesial roots whose canals have some degree of curvature were selected. The mesiobuccal root portion including mesiobuccal portion of a crown was sectioned in each molar. After access cavity preparation for the mesiobuccal canal, working length was determined with # 10 K-file. The sectioned roots were implanted in acrylic resin block and randomly divided into four groups. The canals of group I were shaped by step-down/balanced force, group II by stepdown/step-back, group III by step-back and group IV by conventional method. All of the shaped canals were obturated by Thermafil method and access cavities were filled with IRM. The roots were removed from acrylic resin block and placed in 100 % humidity for 7days. Except the root surfaces of apical 2mm, the root surfaces were nail-varnished 3 times. After the roots were placed in 700 torr vacuum pressure for 15 minutes, they were immersed in 2% methylene blue solution for 4 days. Nail varnishes were removed with acetone. After that, the roots were decalcified in 5 % nitric acid and dehydrated with alcohol series. Transparent specimens were made by methyl salicylate and the quality of apical seal was assessed by measuring the leakage linearly. The results were as follows. 1. The leakage in canals shaped by step-down/balanced force method was significantly less than that in canals shaped by step-back method(P<0.05) and was less but not statistically than that in canals shaped by step-down/step-back method (P>0.05). 2. The leakage in canals shaped by step-down/step-back method was less than that in canals shaped by step-back method, but there was no statistical significance(P>0.05). 3. The leakage in canals shaped by conventional method was significantly more than that in canals shaped by step-down/balanced force, step-down/step-back and step-back method (P<0.05).

  • PDF

A study on the Chopper Control System of Electroic Vehicle (전기자동차의 쵸퍼제어 방식)

  • Chung, Y.T.;Han, K.H.;Kim, Y.J.;Lee, S.H.;Kim, D.G.;Lee, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1182-1184
    • /
    • 1992
  • In case of chopper control is used for the d.c motor In the electric vehicle(EV) in general step down chopper is used for the driving and the step-up chopper is used for the regeneration. Bilateral variable ratio chopper system(BVRCS) formed by parallel combination of upper two chopper methods step-down, step-up and step-up/down chopper operations by duty cycle, circuit element and driving condition. In this paper, BVRCS is proposed for the simulated and experimented control of d.c motor in the EV. By the result of simulation BVRCS represents same driving power compared to the step-down and excellent breaking power compared to the step-up chopper system because of the greater motor current.

  • PDF

A Forward-Integrated Buck DC-DC Converter with Low Voltage Stress for High Step-Down Applications

  • Adivi, Maedeh Ghanbari;Yazdani, Mohammad Rouhollah
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.356-363
    • /
    • 2018
  • The combination of a buck converter and a forward converter can be considered to accomplish a high step-down non-isolated converter. To decrease the insufficient step-down ratio of a regular buck converter and to distribute switch voltage stress, a forward-integrated buck (FIB) converter is proposed in this paper. The proposed interleaved DC-DC converter provides an additional step-down gain with the help of a forward converter. In addition to its simple structure, the transformer flux reset problem is solved and an additional magnetic core reset winding is not required. The operational principle and an analysis of the proposed FIB converter are presented and verified by experimental results obtained with a 240 W, 150 V/24 V prototype.

Characteristics of Step-Down Transformer in PZT Piezoelectric Ceramics (PZT계 압전 세라믹 변압기의 감압특성)

  • 김오수;이준형;손정호;남효덕;조상희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.11
    • /
    • pp.885-891
    • /
    • 2001
  • Ring/dot-type step-down piezoelectric transformer was manufactured by using Pb[(Mn$\sub$1/3/Sb$\sub$2/3)$\sub$0.05/Zr$\sub$0.475/Ti$\sub$0.475/]O$_3$ ceramics, which have excellent high-power piezoelectric properties. The characteristics of step-down piezoelectric transformer as a function of load resistance at output terminal was examined. Voltage gain was greatly dependent on drive frequency and load resistance, and showed maximum voltage gain at the resonance frequency. The output voltage was linearly increased as the input voltage increased. Voltage gain of the step-down piezoelectric transformer with respect to input voltage was very stable when the load resistance was in the range of 50-500 $\Omega$ .

  • PDF

MOBILE APP FOR COMPUTING OPTION PRICE OF THE FOUR-UNDERLYING ASSET STEP-DOWN ELS

  • JUNSEOK, KIM;DAEUN, JEONG;HANBYEOL, JANG;HYUNDONG, KIM
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.26 no.4
    • /
    • pp.343-352
    • /
    • 2022
  • We present the user-friendly graphical user interface design and implementation of Monte Carlo simulation (MCS) for computing option price of the four-underlying asset step-down equity linked securities (ELS) using the Android platform. The ELS has been one of the most important and influential financial products in South Korea. Most ELS products are based on one-, two-, and three-underlying assets. However, currently there is a demand for higher coupon payment from ELS products because of the increased interest rate in financial market. In order to allow the investors to have higher coupon payment, it is necessary to design a multi-asset ELS such as four-asset step-down ELS. We conduct the computational experiments to demonstrate the performance of the Android platform for pricing four-asset step-down ELS. Furthermore, we perform a comparison test with a three-asset step-down ELS.

A risk analysis of step-down equity-linked securities based on regime-switching copula

  • Nguyen, Manh Duc;Ko, Bangwon;Kwon, Hyuk-Sung
    • Communications for Statistical Applications and Methods
    • /
    • v.27 no.1
    • /
    • pp.79-95
    • /
    • 2020
  • The globalization of financial markets has broadened investment opportunities. International investors' investment portfolios consist of financial instruments from various countries; consequently, the risks associated with economic dependence among countries should be carefully considered. Step-down equity-linked securities (ELS) are a structured financial product that have recently become popular among Korean investors. Payoffs are based on two or three stock indices from different regions; therefore, dependence between the indices should be reflected in the risk analysis. In this study, we consider a regime-switching copula model to describe the joint behavior of two stock indices- the Eurostoxx50 and the Hang Seng China Enterprises Index (HSCEI). These indices are commonly used as underlying assets of step-down ELS. Using historical data, we analyze the risk associated with step-down ELS through the probabilities of early redemption. A regime-switching copula model can accommodate complicated dependence. Thus, it should be considered in the risk analysis of step-down ELS.

Voltage Step-down Characteristics of Modified Ring/Dot-type Piezoelectric Transformer using Pb[(Mn1/3Sb2/3)0.05Zr0.475]O3 Ceramics (Pb[(Mn1/3Sb2/3)0.05Zr0.475]O3세라믹스를 이용한 변형 Ring/Dot형 압전세라믹 변압기의 감압특성)

  • 남성진;남효덕;손준호;이준형
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.2
    • /
    • pp.171-177
    • /
    • 2004
  • Voltage step-down characteristics in Ring/Dot type piezoelectric transformer were examined as a function of the area of input electrode when the area of output electrode is fixed. The effects of driving frequency and load resistance on the voltage step-down characteristics were also examined. Voltage gain was greatly dependent on the driving frequency and load resistance, and showed a maximum gain at resonance frequency of the step-down transformer. The frequency where the maximum cutout voltage appears increased about 0.2% as the load resistance increased from 10 to 150 Ω. As the area of input electrode increased, the voltage gain and the efficiency of the transformer increased. Frequency dependence of efficiency of the step-down transformer revealed a similar tendency with the voltage gain curves. The maximum efficiency remarked 94% when the input voltage and the load resistance were 20 Vpp and 120 Ω, respectively.

EFFECT OF "STEP-DOWN" AND "BALANCED FORCE" PREPARATION METHODS ON THE SHAPE OF THE ROOT CANAL (Step-down과 Balanced force 근관성형술식에 의한 근관 형태의 변화)

  • Chin, Cheong-Hee;Kim, Jong-Hwa;Lee, Kwang-Won;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.768-779
    • /
    • 1995
  • This study was performed to investigate the effect of root canal shaping techniques on the change of the shape of prepared root canal. 40 mesiobuccal canals of recently extracted mandibular 1st and 2nd molars were divided into 4 groups and shaped by step-down/balanced force technique, step-down/step-back technique, step-back technique and conventional technique respectively. The change of the shape of root canal was traced by superimposing the radiographs obtained before and after shaping of each root canal. The results were as follows. 1. By the experimented techniques except conventional technique, the root canals were more shaped in convex side of apical area and in concave side of most curved and coronal area than in the other sides(P<0.05). By conventional technique, the root canals were more shaped in convex side than in convave side from apex to orifice(P<0.05). 2. By step-down/balanced force technique, the cancave sides at C and D points of proximal view and C point of clinical view were more shaped than the convex side(P<0.05). Through the entire canal, the concave side was more shaped than the convex side in proximal view(P<0.01). But there was no statistical difference between both sides in clinical view. 3. By step-down/step-back technique, the change of root canal shape was not statistically different in concave and convex sides at each point of both views(P>0.05). And through the entire canal in proximal view, there was no statistical difference in shaping percentage between both sides. But through the entire canal in clinical view, the concave side was more shaped than the convex side(P<0.1). 4. By step-back technique, the convex side at B point of clinical more shaped than the other sides(P<0.05). Through the entire canal in proximal and clinical views, there was no statistical difference in shaping percentage between both sides. 5. Comparing the total shaping percentage among techniques, that in conventional technique was the greatest numerically, and followed by the percentages in step-down/step-back, step-down/balanced force and step-back technique. But, in proximal view, shaping percentages were not statistically different among techniques(P>0.05, ANOVA test). In clinical view, shaping percentages in step-back and conventional techniques were statistically different(P<0.01, ANOVA test). * Proximal view: radiograph taken in mesiodistal direction. * Clincal view: radiograph taken in faciolingual direction. A point : 1mm point from radiographic apex B point : center point between A and C points C point : most curved point of root canal D point : center point between C point and canal oriffice.

  • PDF

Effect of Step-up and Step-down Hyperthermia on Skin of Mice (온열요법시 온도변화가 정상조직에 미치는 영향)

  • Choi, Ihl-Bohng;Kim, Choon-Yul;Bahk, Yong-Whee
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.155-161
    • /
    • 1988
  • The usefulness of hypertermia for cancer therapy have well been established. The purpose of the present investigation was to ascess the effect of step-up $(42^{\circ}{\rightarrow}44^{\circ}C$ sequence) and step-down $(44^{\circ}{\rightarrow}42^{\circ}C$ sequence) heating on the skin of the hind foot of the mouse. Hyperthermic treatments were given by immersion the hind foot of the mouse in circulating water baths. Skin response was studied by the leg reaction, which was scored according to a numerical scoring system proposed by Urano et al (1980). The results were as follows 1. The skin damage of $44^{\circ}C$ control group was more severe than $42^{\circ}C$ control group (P<0.05), except for 15 min. heating group. 2. The Skin damage of step-down group was more severe than step-up group (P<0.05). 3. The skin damage of $44^{\circ}C$ control group was more severe than step-up group when there is no difference in $44^{\circ}C$ heating time of step-up group from $44^{\circ}C$ control group (P<0.05). 4. In step-down group, the skin damage was more severe than $44^{\circ}C$ control group after preheating 45 min at $44^{\circ}C$ (P<0.05). Therefore, the above findings suggest the normal tissue damage by step-up heating was correlated with heating time of post step-up. The dropping of heating temperature in late phase had more severe damage of the skin than that in early phase during hyperthermia, and so contineous control of satisfactory temperature should be considered as the one of the most important factor for prognosis, complications of clinical hyperthermia

  • PDF