• Title/Summary/Keyword: sterilize

Search Result 91, Processing Time 0.025 seconds

A Study on Ensuring the Safety of Potable UV Space Germicidal Equipment (이동형 UV 공간 살균 기기의 안전성 확보 방안에 관한 연구)

  • Han-Seok Cheong;Chung-Hyeok Kim;Jin-Sa Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.1
    • /
    • pp.94-100
    • /
    • 2024
  • Recently, as interest in personal hygiene has increased due to the community spread of COVID-19 and variant viruses, fixed and potable UV germicidal equipment to sterilize indoor spaces and hand-held UV germicidal equipment to sterilize household items such as masks and mobile phones are continuously being developed and sold. However, the development and sales of the product are difficult because appropriate testing methods have not yet been established. In this situation, if an uncertified product is distributed in the market, it can cause serious harm to consumers. In this study, we investigate the photobiological risks and safety devices against UV exposure of UV germicidal equipment distributed domestically, and propose appropriate test methods for portable UV germicidal equipment based on the research results.

Postpneumonectomy Empyema That Occurred 27 1/2 Years After Initial Pneumonectomy -A Case Report- (전폐절제술후 27년 6개월에 발생한 농흉 치험 -1례 보고-)

  • 이광선
    • Journal of Chest Surgery
    • /
    • v.28 no.5
    • /
    • pp.504-506
    • /
    • 1995
  • Postpneumonectomy empyema is an infrequent but dreaded complication. The seriousness of this complication is impossible to eliminate the space containing the infection, and consequently, it is difficult to sterilize the space. The time from pneumonectomy to the development of an empyema ranges from several days to several years, with most evident with 4 weeks. We experienced a case of postpneumonectomy empyema that occurred 27 1/2 years after initial pneumonectomy. She was treated with intrapleural antiseptic irrigation and open-tube drainage following partial decortication. The patient had an uneventful recovery and was discharged from hospital with improved condition.

  • PDF

The Technical Trend and Prospect of Ozonizer (오존발생기의 기술동향 및 전망)

  • Cho, Kook-Hee;Kim, Young-Bae;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1655-1657
    • /
    • 2001
  • Ozone is widely used to sterilize food and tap water because ozone is a strong oxidizer. Efficient ozone generation is the most important issue in the field of ozone application. A variable discharge type of ozonizer that generates diffuse glow discharge in air at atmospheric pressure was used for the efficient ozone generation.

  • PDF

Acute Postpneumonectomy Empyema with Bronchopleural Fistula Treated with Vacuum-assisted Closure Device

  • Han, Woo-Sik;Kim, Kwhan-Mien
    • Journal of Chest Surgery
    • /
    • v.45 no.4
    • /
    • pp.260-262
    • /
    • 2012
  • Postpneumonectomy empyema is a life-threatening complication, which is often related with a bronchopleural fistula. After surgical repair of fistula, sterilization of infected pleural cavity is important and usually carried out by long-term cyclic irrigation. We report a case in which vacuum-assisted closure device was successfully applied to sterilize the pleural cavity and obliterate bronchopleural fistula.

Status of Facilities, Equipment, and Environmental Hygiene Management of School Foodservices in Daiyue-district, Taian-city, China (중국 태안시 다이웨구 학교급식소의 시설·기구·환경 위생관리 실태)

  • Cheng, Xiao Xia;Moon, Hye-Kyung
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.59-66
    • /
    • 2021
  • The results of the inspection based on the sanitation checklist and the measurement of refrigerator/freezer temperature, illuminance, and ATP were conducted at 12 school foodservices in Daiyue-district, Taian-city, Shandong Province, China, at the same time, and the results were as follows. Five items of 'Use sterilized cutting boards', 'Use sterilized knives', 'Use worktable after sterilization', 'Use sink after sterilization', 'Sterilize the interior/exterior of the refrigerator regularly' in the checklist inspection were found not to be performed (0%). Two items of 'Disinfect hands after washing', 'Equipped with hand sterilizer' and 'Sterilize the kitchen areas regularly' were investigated as being performed only in one foodservice (8%). The average illuminance of the receiving stand were 373.08±106.35 Lux, 8% when the standard (540 Lux or higher) was complied with, the average refrigerator temperature were 7.06±0.82℃, 38.9% when the standard (-2 to 5℃) was observed 8% of cases complying with the standard (below -18℃) at -8.56±0.76℃ were investigated. As a result of ATP measurement, the surfaces of knife edge, cutting board, refrigerator door handle, worktable, and sink, which are not sterilized at all, were not suitable (accept ratio 0%), sterilized food plate (accept ratio 54.2%) and utensil for preserved food (accept ratio 75%) had a relatively high accept ratio. China's hygiene regulations should be revised in the direction of strengthening disinfection practices for facilities, equipment, and the environment, and hygiene measures such as education on disinfection and preparation of economical disinfection methods should be established.

Discharge Waveform Properties on Electrical Sterilization by HV Impulse (고전압 펄스에 의한 전기 살균에서 방전 파형의 특성 분석)

  • Lee, H.K.;Suehiro, J.;Hara, M.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.944-946
    • /
    • 1998
  • We evaluated cell survivability by changing RLC value on HV impulse network. When the L value is changed from 0 to 10mH in this circuit. we found that cell survivability is shown large decline with 4mH of L value. I respect to this result, when waveshapes of oscillatory decay are presented along the variation of L value in RLC circuit, we analyzed whether discharge waveform properties have an effect on sterilization ratio, and measured threshold voltage as the minimum peak voltage of a single pulse which can sterilize cells. Finally, we found that the sterilization effect was related to number of threshold voltage waveforms being applied.

  • PDF

Disinfection Efficacy of an Ultraviolet Light on Film Cassettes for Preventive of the Nosocomial Infection (병원감염 예방을 위한 Film Cassette의 자외선 소독 효과)

  • Kweon, Dae-Cheol;Jeon, Yong-Woong;Cho, Am
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2001
  • The bacteria infection on film cassette contact surface was examined at the diagnostic radiology department of the S. hospital. The objective of this study was to assess the contamination level on film cassette contact surface as a predictor of patient prevention from nosocomial infection and for improvement of the hospital environment. The laboratory result was identified non-pathologic bacterial in the five different cassette size of the contact surface. Film cassettes were exposed to ultraviolet light for 1, 2 and 3 minutes. Ultraviolet light disinfection is proven suitable for bacteria. The study concludes that presence of a bacterial infection will prevent a using antiseptic technique on film cassette contact surface. In addition education of nosocomial infection for radiographers will be required. In conclusion, ultraviolet is considered effective to irradate bacteria. Additionally, two minutes are required to sterilize film cassettes.

  • PDF

의약품 제조시설의 포름알데히드가스 훈증살균과 최근 실내무균화방법의 동향

  • 한국공기청정협회
    • Air Cleaning Technology
    • /
    • v.23 no.3
    • /
    • pp.34-43
    • /
    • 2010
  • In most productive facility of pharmaceutical companies, the fumigation using formaldehyde gas has been put into operation. Because formaldehyde gas is so bactericidal as to sterilize bacterial spore which can not be sterilized with usual disinfectants, it has been used for fumigation in many facilities such as facility of experimental animals, research institute and productive facility of pharmaceutical companies which are required to be high level of biological clean. However, the use of formaldehyde is recently under the strict management because of its causing of sick house and carcinogenesis. We introduce the conditions of sterilization using formaldehyde gas, the examples of sterilization using formaldehyde gas in a pharmaceutical manufacture and the problems of use of formaldehyde against environments and health. Further, we describe the characteristics and future subjects of the sterilization method using gasified oxidants such as hydrogen peroxide, peracetic acid and chlorine oxide.

  • PDF

A Study on the Water Sterilizer using the Microwave (마이크로파를 이용한 물 살균장치에 관한 연구)

  • 이창호;이화용
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.113-117
    • /
    • 2004
  • In this paper, we present a new microwave applicator to sterilize a liquid material by using the electromagnetic energy. Also, we conducted an experiment on streamlet water with our proposed sterilizer and investigated the chosen samples according to the inspection agency The result exhibited that the total number of colitis germ and general bacillus in sterilized water has been decreased rapidly as the operating time to illuminate the microwave power risen from 10 to 60 seconds.

A Study on Sterilization of Medical Products by Gamma-irradiation. (Gamma선 조사에 의한 의류제품의 멸균연구)

  • 정해원;정문식;문석형
    • Journal of Environmental Health Sciences
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1978
  • Biological safety, physico-chemical and microbiological experiments were carried out in order to study the possibility of radiation sterilization on medical products, such as polyethylene and polystyrene bottles, gauze sponges and surgical silk suture. Results are as follows: 1. Biological test on plastic samples as to acute systemic toxicity, eye irritation, skin irritation, pyrogen, haemolysis showed satisfactory results. But physico-chemically, the oxidizable matter, nonvolatile residues, residue on ignition seemed to be increased slightly in irradiated samples, though the experimental results were within the range of U.S.P. 19, N.F. and K.P. III. 2. After irradiation, both plastic and gauze sponges showed considerable decrease in pH. 3. Most medical products were sterilized by 1.5 Mard. For the sterilization of the suigical silk suture, 4.5 Mrad is required dul to its radiation resistant micro-organisms. 4. Biologically, total dose of 2.5 Mrad was safe enough to sterilize the medical products, and physico-chemically the results are acceptable according to U.S.P. 19 and K.P. III. However, better results may be expected when the quality of material and additives are improved.

  • PDF