• Title/Summary/Keyword: strong earthquakes

Search Result 321, Processing Time 0.026 seconds

Stochastic Prediction of Strong Ground Motions and Attenuation Equations in the Southeastern Korean peninsular (한반도 동남부의 강진동 모사와 감쇠식)

  • 이정모
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.70-80
    • /
    • 2000
  • In order to reduce seismic hazard the characteristics of strong earthquakes are required. In the region where strong earthquakes do not happen frequently the stochastic simulation of strong motion is an alternative way to predict strong motions. this simulation required input parameters such as the quality factor the corner frequency the moment magnitude the stress drop and so on which can be obtained from analyses of records of small and intermediate earthquakes. Using those parameters obtained in the previous work the strong ground motions are predicted employing the stochastic method, . The results are compared to the two observed earthquakes-the Ulsan Offshore Earthquake and the Kyungju Earthquake. Although some deviations are found the predictions are similar to the observed data. Finally we computed attenuation equations for PGA PGV and ground accelerations for some frequencies using the results of predictions. These results can be used for earthquake engineering and more reliable results will come out as earthquake observations continue.

  • PDF

Effects of strong ground motions of near source earthquakes on response of thin-walled L-shaped steel bridge piers

  • Xie, Guanmo;Taniguchi, Takeo;Chouw, Nawawi
    • Structural Engineering and Mechanics
    • /
    • v.12 no.3
    • /
    • pp.341-346
    • /
    • 2001
  • Near source earthquakes can be characterized not only by strong horizontal but also by strong vertical ground motions with broad range of dominant frequencies. The inelastic horizontal response of thin-walled L-shaped steel bridge piers, which are popularly used as highway bridge supports, subjected to simultaneous horizontal and vertical ground excitations of near source earthquakes is investigated. A comprehensive damage index and an evolutionary-degrading hysteretic model are applied. Numerical analysis reveals that the strong vertical excitation of a near source earthquake exerts considerable influences on the damage development and horizontal response of thin-walled L-shaped steel bridge piers.

Assessment of seismic parameters for 6 February 2023 Kahramanmaraş earthquakes

  • Bilal Balun
    • Structural Engineering and Mechanics
    • /
    • v.88 no.2
    • /
    • pp.117-128
    • /
    • 2023
  • On February 6, 2023, Türkiye woke up with a strong ground motion felt in a wide geography. As a result of the Kahramanmaraş, Pazarcık and Elbistan earthquakes, which took place 9 hours apart, there was great destruction and loss of life. The 2023 Kahramanmaraş earthquakes occurred on active faults known to pose a high seismic hazard, but their effects were devastating. Seismic code spectra were investigated in Hatay, Adıyaman and Kahramanmaraş where destruction is high. The study mainly focuses on the investigation of ground motion parameters of 6 February Kahramanmaraş earthquakes and the correlation between ground motion parameters. In addition, earthquakes greater than Mw 5.0 that occurred in Türkiye were compared with certain seismic parameters. As in the strong ground motion studies, seismic energy parameters such as Arias intensity, characteristic intensity, cumulative absolute velocity and specific energy density were determined, especially considering the duration content of the earthquake. Based on the study, it was concluded that the structures were overloaded far beyond their normal design levels. This, coupled with significant vertical seismic components, is a contributing factor to the collapse of many buildings in the area. In the evaluation made on Arias intensity, much more energy (approximately ten times) emerged in Kahramanmaraş earthquakes compared to other Türkiye earthquakes. No good correlation was found between moment magnitude and peak ground accelerations, peak ground velocities, Arias intensities and ground motion durations in Türkiye earthquakes. Both high seismic components and long ground motion durations caused intense energy to be transferred to the structures. No strong correlation was found between ground motion durations and other seismic parameters. There is a strong positive correlation between PGA and seismic energy parameter AI. Kahramanmaraş earthquakes revealed that changes should be made in the Turkish seismic code to predict higher spectral acceleration values, especially in earthquake-prone regions in Türkiye.

Investigation on damage development of AP1000 nuclear power plant in strong ground motions with numerical simulation

  • Chen, Wanruo;Zhang, Yongshan;Wang, Dayang;Wu, Chengqing
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1669-1680
    • /
    • 2019
  • Seismic safety is considered to be one of the key design objectives of AP1000 nuclear power plant (NPP) in strong earthquakes. Dynamic behavior, damage development and aggravation effect are studied in this study for the three main components of AP1000 NPP, namely reinforced concrete shield building (RCSB), steel vessel containment (SVC) and reinforced concrete auxiliary building (RCAB). Characteristics including nonlinear concrete tension and compressive constitutions with plastic damage are employed to establish the numerical model, which is further validated by existing studies. The author investigates three earthquakes and eight input levels with the maximum magnitude of 2.4 g and the results show that the concrete material of both RCSB and RCAB have suffered serious damage in intense earthquakes. Considering RCAB in the whole NPP, significant damage aggravation effect can be detected, which is mainly concentrated at the upper intersection between RCSB and RCAB. SVC and reinforcing bar demonstrate excellent seismic performance with no obvious damage.

On the variability of strong ground motions recorded from Vrancea earthquakes

  • Pavel, Florin;Vacareanu, Radu;Arion, Cristian;Neagu, Cristian
    • Earthquakes and Structures
    • /
    • v.6 no.1
    • /
    • pp.1-18
    • /
    • 2014
  • The main focus of this paper is the analysis of the different components of the variability for strong ground motions recorded from earthquakes produced by the Vrancea subcrustal seismic source. The analysis is performed for two ground motion prediction equations: Youngs et al. (1997) and Zhao et al. (2006), recommended within the SHARE project for the Vrancea subcrustal seismic source and which are proposed in the work of Delavaud et al. (2012) and graded best in Vacareanu et al. (2013c). The first phase of the analysis procedure consists of a grading procedure. In the second phase, the single station sigma procedure is applied for both attenuation models in order to reduce some parts of ground motion models' variability produced by the ergodic assumption. The strong ground motion database which is used throughout the study consists of over 400 accelerograms recorded from 9 Vrancea intermediate-depth seismic events. The results of the single station sigma analysis show significant reduction of the standard deviations, especially in the case of the Youngs et al. (1997) attenuation model, which is also graded better than the other selected GMPE.

Some Characteristics of Seismicity and Stress State in the Korean Peninsula Using the Korean Seismic Data of the Past and the Present (과거 및 현재 지진 Data로부터 한반도 지진활동과 응력 상태)

  • 오충량;김소구;고복춘
    • The Journal of Engineering Geology
    • /
    • v.5 no.3
    • /
    • pp.309-329
    • /
    • 1995
  • Seismicity and stress state in the Korean peninsula are studied using the catalogue of historical earthquakes and that from the seismological observations before the 1960s, with the aid of instrumental catalogue up to 1995. It seems that the completeness of the historical catalogue has a significant enhancement during the first two hundred years of the Yi dynasty, i.e., from the 1400s to the 1600s. From then on the catalogue may be regarded as near to complete for strong earthquakes in an overall sense. From the distribution of strong earthquakes, three seismic zones may be identified. From the south to the north, those are the southern seismic zone (남부지진대), the Seoul-Pyongyang seismic zone (서울-평양지진대), and the northern seismic zone (북부지진대). The mechanisms of some earthquakes obtained using first motion read- ings are reevaluated with a grid testing method. The results indicate that the compressional axis is nearly horizontal along the EW direction.

  • PDF

Seismic assessment and retrofitting measures of a historic stone masonry bridge

  • Rovithis, Emmanouil N.;Pitilakis, Kyriazis D.
    • Earthquakes and Structures
    • /
    • v.10 no.3
    • /
    • pp.645-667
    • /
    • 2016
  • The 750 m long "De Bosset" bridge in the Cephalonia Island of Western Greece, being the area with the highest seismicity in Europe, was constructed in 1830 by successive stone arches and stiff block-type piers. The bridge suffered extensive damages during past earthquakes, such as the strong M7.2 earthquake of 1953, followed by poorly-designed reconstruction schemes with reinforced concrete. In 2005, a multidisciplinary project for the seismic assessment and restoration of the "De Bosset" bridge was undertaken under the auspices of the Greek Ministry of Culture. The proposed retrofitting scheme combining soil improvement, structural strengthening and reconstruction of the deteriorated masonry sections was recently applied on site. Design of the rehabilitation measures and assessment of the pre- and post-interventions seismic response of the bridge were based on detailed in-situ and laboratory tests, providing foundation soil and structural material properties. In-situ inspection of the rehabilitated bridge following the strong M6.1 and M6.0 Cephalonia earthquakes of January 26th and February 3rd 2014, respectively, revealed no damages or visible defects. The efficiency of the bridge retrofitting is also proved by a preliminary performance analysis of the bridge under the recorded ground motion induced by the above earthquakes.

Strategic width-wise arrangement of viscous dampers in steel buildings under strong earthquakes

  • Huang, Xiameng
    • Earthquakes and Structures
    • /
    • v.20 no.2
    • /
    • pp.225-238
    • /
    • 2021
  • Supplemental passive dampers are widely employed to improve the structural performance of buildings under seismic excitations. Nevertheless, the added damping could be counter-productive if the axial forces induced by the damper reaction forces are not routed properly in the columns. A few researchers engaged to optimize the width-wise damper arrangement to improve the delivered path of the axial column forces. However, most of these studies are limited under the design-based seismic level and few of them has evaluated the collapse performance of buildings under strong earthquakes. In this paper, the strategic width-wise placement method of viscous dampers is explored regarding the building performance under collapse state. Two realistic steel buildings with different storeys are modelled and compared to explore higher mode effects. Each building is designed with four different damper arrangement scenarios based on a classic damper distribution method. Both a far-fault and a near-fault seismic environment are considered for the buildings. Incremental Dynamic Analysis (IDA) is performed to evaluate the probability of collapse and the plastic mechanism of the retrofitted steel buildings.

Masonry building behaviors during the February 6-12, 2017 Ayvacik-Çanakkale Earthquakes

  • Ural, Ali
    • Earthquakes and Structures
    • /
    • v.17 no.4
    • /
    • pp.355-363
    • /
    • 2019
  • Masonry structures in the rural areas of Turkey often damaged due to moderate and big earthquakes. After every earthquake many scientists made field investigations on the earthquake performance of these structures and gave many useful information on construction techniques. However, the newly constructed masonry buildings are still not suitable for the suggested techniques, and they are still in danger against future earthquakes. Five moderate earthquakes of moment magnitude Mw 5.3, 5.3, 5.2, 5.0, and 5.3 struck the Ayvacik-Çanakkale District of Turkey between 6 and 12 February, 2017. More than a thousand of aftershocks were occurred and most of the masonry buildings in the villages nearby main shock epicenter were affected. The author went to the earthquake field and investigated the earthquake performances of masonry structures. This paper presents the recorded acceleration data, acceleration response spectra, and the seismological aspects of these earthquakes. Besides, case studies of damaged stone masonry buildings, and failure mechanisms are discussed with illustrated photos which were taken during the field investigations. It is concluded that the damaged masonry buildings were not designed and constructed properly in accordance with the Turkish building codes or similar specifications.

Strong earthquakes and measurement performance of masonry and adobe structures

  • Liu, Yanling;Han, Qinkia
    • Structural Engineering and Mechanics
    • /
    • v.47 no.1
    • /
    • pp.99-118
    • /
    • 2013
  • Earthquakes, which are unavoidable natural phenomena in Turkey, have often produced economic and social disaster. The latest destructive earthquakes happened in Van city. Van, Turkey, earthquakes with M = 7.2 occurred on 23 October 2011 at 13:41 (local time), whose epicenter was about 16 km north of Van (Tabanlivillage) and M = 5.6 on 9 November 2011 epicentered near the town of Edremit south of Van in eastern Turkey and caused the loss of life and heavy damages. Both earthquakes killed 644 people and 2608 people were injured. Approximately 4000 buildings collapsed or were seriously damaged. The majority of the damaged structures were seismically insufficient, unreinforced masonry and adobe buildings in rural areas. In this paper, site surveys of the damaged masonry and adobe buildings are presented and the reasons for the caused damages are discussed in detail.