• Title/Summary/Keyword: structural fuse

Search Result 39, Processing Time 0.03 seconds

Experimental investigations on resilient beam-column end-plate connection with structural fuse

  • Arunkumar Chandrasekaran;Umamaheswari Nambiappan
    • Steel and Composite Structures
    • /
    • v.47 no.3
    • /
    • pp.315-337
    • /
    • 2023
  • The steel structure is an assembly of individual structural members joined together by connections. The connections are the focal point to transfer the forces which is susceptible to damage easily. It is challenging to replace the affected connection parts after an earthquake. Hence, steel plates are utilised as a structural fuse that absorbs connection forces and fails first. The objective of the present research is to develop a beam-column end plate connection with single and dual fuse and study the effect of single fuse, dual fuse and combined action of fuse and damper. In this research, seismic resilient beam-column end plate connection is developed in the form of structural fuse. The novel connection consists of one main fuse was placed horizontally and secondary fuse was placed vertically over main fuse. The specimens are fabricated with the variation in number of fuse (single and dual) and position of fuse (beam flange top and bottom). From the fabricated ten specimens five specimens were loaded monotonically and five cyclically. The experimental results are compared with Finite Element Analysis results of Arunkumar and Umamaheswari (2022). The results are critically assessed in the aspect of moment-rotation behaviour, strain in connection components, connection stiffness, energy dissipation characteristics and ductility. While comparing the performance of total five specimens, the connection with fuse exhibited superior performance than the conventional connection. An equation is proposed for the moment of resistance of end-plate connection without and with structural fuse.

Assessment for Failure Probability of Landing Gear Structural Fuse and Improvement Measure (착륙장치용 Structural Fuse 파손확률 계산 및 개선 방안)

  • Lee, Seung-Gyu;Kim, Tae-Uk;Hwang, In-Hee;Lee, Jeong-Sun;Jo, Jeong-Jun;Park, Chong-Yeong
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.469-474
    • /
    • 2008
  • The reason for crashworthy landing gear is to contribute to the overall aircraft design goals in the event of a crash. One of crashworthy landing gear design approaches is inclusion of structural fuse. Structural fuse is used to control the mode of failure of landing gear. If structural fuse doesn't work at desired condition, other unexpected accidents can occur. In this paper, failure probability is calculated for landing gear structural fuse and improvement measure is introduced to improve failure probability of structural fuse.

  • PDF

Application of frictional sliding fuse in infilled frames, fuse adjustment and influencing parameters

  • Mohammadi-Gh, M.;Akrami, V.
    • Structural Engineering and Mechanics
    • /
    • v.36 no.6
    • /
    • pp.715-727
    • /
    • 2010
  • An experimental investigation is conducted here to study the effects of applying frictional sliding fuses (FSF) in concrete infilled steel frames. Firstly, the influences of some parameters on the behavior of the sliding fuse are studied: Methods of adjusting the FSF for a certain sliding strength are explained and influences of time duration, welding and corrosion are investigated as well. Based on the results, time duration does not significantly affect the FSF, however influences of welding and corrosion of the constitutive plates are substantial. Then, the results of testing two 1/3 scale single-storey single-bay concrete infilled steel frames having FSF are presented. The specimens were similar, except for different regulations of their fuses, tested by displacement controlled cyclic loading. The results demonstrate that applying FSF improves infill behaviors in both perpendicular directions. The infilled frames with FSF have more appropriate hysteresis cycles, higher ductility, much lower deteriorations in strength and stiffness in comparison with regular ones. Consequently, the infills, provided with FSF, can be regarded as an engineered element, however, special consideration should be taken into the affecting parameters of their fuses.

Experimental and numerical evaluation of rigid connection with reduced depth section

  • Garoosi, Allah Reza Moradi;Roudsari, Mehrzad Tahamouli;Hashemi, Behrokh Hosseini
    • Steel and Composite Structures
    • /
    • v.34 no.6
    • /
    • pp.863-875
    • /
    • 2020
  • After medium or strong earthquakes, damage in the reduced portion of RBS connections occurs due to plastic deformations. The purpose of this paper is to numerically and experimentally investigate the reduced depth section connection as a replaceable fuse. In this regard, three commonly used rigid connections with RBS, a replaceable fuse with RBS, and a replaceable fuse with Reduced Depth Section (RDS-F) were evaluated. All specimens were subjected to quasi-static cyclic load until failure. Although the final strength of the RDS-F is lower than that of the other two, laboratory results showed that it had the maximum ductility among the three samples. The numerical models of all three laboratory samples were constructed in ABAQUS, and the results were verified with great accuracy. The results of more than 28 numerical analyses showed that the RDS-F sample is more ductile than the other specimens. Moreover, the thickness of the web and the plastic section modulus increasing, the final strength would be equal to the other specimens. Therefore, the modified RDS-F with replaceability after an earthquake can be a better alternative for RBS connections.

Experimental and numerical study of a proposed steel brace with a localized fuse

  • Parsa, Elham;Ghazi, Mohammad;Farahbod, Farhang
    • Structural Engineering and Mechanics
    • /
    • v.84 no.2
    • /
    • pp.269-283
    • /
    • 2022
  • In this paper, a particular type of all-steel HSS brace members with a locally reduced cross-sectional area was experimentally and numerically investigated. The brace member was strengthened against local buckling with inner and outer boxes in the reduced area. Four single-span braced frames were tested under cyclic lateral loadings. Specimens included a simple steel frame with a conventional box-shaped brace and three other all-steel reduced section buckling-restrained braces. After conducting the experimental program, numerical models of the proposed brace were developed and verified with experimental results. Then the length of the proposed fuse was increased and its effect on the cyclic behavior of the brace was investigated numerically. Eventually, the brace was detailed with a fuse-to-brace length of 30%, as well as the cross-sectional area of the fuse-to-brace of 30%, and the cyclic behavior of the system was studied numerically. The study showed that the proposed brace is stable up to a 2% drift ratio, and the plastic cumulative deformation requirement of AISC (2016) is easily achieved. The proposed brace has sufficient ductility and stability and is lighter, as well as easier to be fabricated, compared to the conventional mortar-filled BRB and all-steel BRB.

Performance of innovative composite buckling-restrained fuse for concentrically braced frames under cyclic loading

  • Mohammadi, Masoud;Kafi, Mohammad A.;Kheyroddin, Ali;Ronagh, Hamid R.
    • Steel and Composite Structures
    • /
    • v.36 no.2
    • /
    • pp.163-177
    • /
    • 2020
  • Concentrically Braced Frames (CBFs) are commonly used in the construction of steel structures because of their ease of implementation, rigidity, low lateral displacement, and cost-effectiveness. However, the principal disadvantage of this kind of braced frame is the inability to provide deformation capacity (ductility) and buckling of bracing elements before yielding. This paper aims to present a novel Composite Buckling Restrained Fuse (CBRF) to be utilized as a bracing segment in concentrically braced frames that allows higher ductility and removes premature buckling. The proposed CBRF with relatively small dimensions is an enhancement on the Reduced Length Buckling Restrained Braces (RL-BRBs), consists of steel core and additional tensile elements embedded in a concrete encasement. Employing tensile elements in this composite fuse with a new configuration enhances the energy dissipation efficiency and removes the tensile strength limitations that exist in bracing elements that contain RL-BRBs. Here, the optimal length of the CBRF is computed by considering the anticipated strain demand and the low-cyclic fatigue life of the core under standard loading protocol. An experimental program is conducted to explore the seismic behavior of the suggested CBRF compare with an RL-BRB specimen under gradually increased cyclic loading. Moreover, Hysteretic responses of the specimens are evaluated to calculate the design parameters such as energy dissipation potential, strength adjustment factors, and equivalent viscous damping. The findings show that the suggested fuse possess a ductile behavior with high energy absorption and sufficient resistance and a reasonably stable hysteresis response under compression and tension.

Hysteretic behavior of dissipative welded fuses for earthquake resistant composite steel and concrete frames

  • Calado, Luis;Proenca, Jorge M.;Espinha, Miguel;Castiglioni, Carlo A.
    • Steel and Composite Structures
    • /
    • v.14 no.6
    • /
    • pp.547-569
    • /
    • 2013
  • In recent years there has been increasing international interest about designing structures that cost less to repair after they have been subjected to strong earthquakes. Considering this interest, an innovative repairable fuse device has been developed for dissipative beam-to-column connections in moment-resisting composite steel and concrete frames. The seismic performance of the device was assessed through an extensive experimental program comprising ten cyclic and two monotonic tests. These tests were conducted on a single beam-to-column specimen with different fuse devices for each test. The devices varied in terms of the chosen geometric and mechanical parameters. The tests showed that the devices were able to concentrate plasticity and to dissipate large amounts of energy through non-linear behavior. Numerical models were developed with Abaqus and simplified design models are also proposed.

Two-level control system of toggle braces having pipe damper and rotational friction damper

  • Ata Abdollahpour;Seyed Mehdi Zahrai
    • Structural Engineering and Mechanics
    • /
    • v.86 no.6
    • /
    • pp.739-750
    • /
    • 2023
  • This study examines the two-level behavior of the toggle brace damper within a steel frame having a yielding pipe damper and rotational friction damper. The proposed system has two kinds of fuse for energy dissipation in two stages. In this mechanism, rotational friction damper rather than hinged connection is used in toggle brace system, connected to a pipe damper with a limited gap. In order to create a gap, bolted connection with the slotted hole is used, such that first a specific movement of the rotational friction damper solely is engaged but with an increase in movement, the yielding damper is also involved. The performance of the system is such that at the beginning of loading the rotational friction damper, as the first fuse, absorbs energy and with increasing the input load and further movement of the frame, yielding damper as the second fuse, along with rotational friction damper would dissipate the input energy. The models created by ABAQUS are subjected to cyclic and seismic loading. Considering the results obtained, the flexibility of the hybrid two-level system is more comparable to the conventional toggle brace damper. Moreover, this system sustains longer lateral displacements. The energy dissipation of these two systems is modeled in multi-story frames in SAP2000 software and their performance is analyzed using time-history analysis. According to the results, permanent relocations of the roof in the two-level system, in comparison with toggle brace damper system in 2, 5, and 8-story building frames, in average, decrease by 15, 55, and 37% respectively. This amount in a 5-story building frame under the earthquakes with one-third scale decreases by 64%.

Application of Structural Fuse Concept to Bridge Joint Design (교량의 이음부 설계를 위한 구조적 퓨즈 개념의 적용)

  • Lee, Jung Whee
    • Magazine of the Korea Institute for Structural Maintenance and Inspection
    • /
    • v.18 no.4
    • /
    • pp.77-82
    • /
    • 2014
  • 본 기사는 교량의 이음부(joint) 설계를 위한 새로운 구조적 퓨즈 개념을 다루고 있다. 제안하는 개념은 경제성, 명확한 하중경로, 그리고 지진 후 보수의 용이성 등을 포함한 여러 가지 장점을 가지고 있다. 기본적인 아이디어는 평상시의 사용 상태에서는 탄성거동을 할 수 있을 정도로 강하지만 동시에 주요 지진이 발생하였을 때는 파괴될 수 있을 정도로 약한 구조적 퓨즈를 설계하여 지진에너지가 퓨즈를 통과하지 못하도록 하겠다는 것이다. 두 가지의 대표적인 프로젝트를 소개하여 구조적 퓨즈의 개념이 실무에 어떻게 성공적으로 적용될 수 있었는지 보이고자 한다.

  • PDF

Experimental studies into a new type of hybrid outrigger system with metal dampers

  • Wang, A.J.
    • Structural Engineering and Mechanics
    • /
    • v.64 no.2
    • /
    • pp.183-194
    • /
    • 2017
  • This paper presents the experimental investigation into a new type of steel-concrete hybrid outrigger system developed for the high-rise building structure. The steel truss is embedded into the reinforced concrete outrigger wall, and both the steel truss and concrete outrigger wall work compositely to enhance the overall structural performance of the tower structures under extreme loads. Meanwhile, metal dampers of low-yield steel material were also adopted as a 'fuse' device between the hybrid outrigger and the column. The damper is engineered to be 'scarified' and yielded first under moderate to severe earthquakes in order to protect the structural integrity of important structural components of the hybrid outrigger system. As such, not brittle failure is likely to happen due to the severe cracking in the concrete outrigger wall. A comprehensive experimental research program was conducted into the structural performance of this new type of hybrid outrigger system. Studies on both the key component and overall system tests were conducted, which reveal the detailed structural response under various levels of applied static and cyclic loads. It was demonstrated that both the steel bracing and concrete outrigger wall are able to work compositely with the low-yield steel damper and exhibits both good load carrying capacities and energy dispersing performance through the test program. It has the potential to be applied and enhance the overall structural performance of the high-rise structures over 300 m under extreme levels of loads.